9.4.4 Example

Example of "Weekday metering"
Com‐
Time event
mand
01
Init
02
workdays 1 (Mo-
Fr)
03
workdays 1 (Mo-
Fr)
04
workdays 1 (Mo-
Fr)
05
workdays 1 (Mo-
Fr)
06
workdays 1 (Mo-
Fr)
07
workdays 1 (Mo-
Fr)

'Service'

9.5

'Password'

9.5.1

'Clear counter'

9.5.2
'Clear all' menu to clear all commands (the program).
Use the
The pump is to meter 2 litres every half hour every weekday (Mon-Fri)
between 8:00 and 11:00:
Time of day
Action
-
Stop
08:30
Manual
08:40
Stop
09:30
Manual
09:40
Stop
10:30
Manual
10:40
Stop
Explanation: At a capacity of 12 l/h, the pump has to work for 10 minutes
to meter 2 litres.
'Menu / Information è Service è ...'
'Menu / Information è Service è Password è ...'
You can lock the setting options here.
If you have set a
after 1 minute in the top left and the setting options are locked - if no key
has been pressed in the meantime.
In the meantime, a key appears there and a small progress bar.
'Menu / Information è Service è Clear counter è ...'
You can reset the counter to "0" in the
Capacity
-
12,000 l/h
-
12,000 l/h
-
12,000 l/h
-
'Password' - see below, then the identifier
'Clear counter' menu:
'Menu'
Set up/
Comment
// Ensure that the
pump is at a
standstill at the
start.//
//Meter with
12,000 l/h//
//Stop//
//Meter with
12,000 l/h//
//Stop//
//Meter with
12,000 l/h//
//Stop//
appears