Repair
Repairing ball valves
70
Only with "Physiologically safe" design:
WARNING!
Product can be dangerously contaminated
Only use the spare parts from the "Physiologically safe"
spare parts kits.
Personnel:
n
CAUTION!
Warning of personal injury and material damage
Feed chemical may escape from the liquid end, for
example, if ball valves are not repaired correctly.
Only use new components which fit your valve, both
in terms of shape and chemical resistance!
Note the flow direction of the pressure and suction
connectors when fitting the valve.
CAUTION!
Warning of feed chemical spraying around
PTFE seals, which have already been used / com‐
pressed, can no longer reliably seal a hydraulic connec‐
tion.
New, unused PTFE seals must always be used.
Fig. 35: Ball valve, simple, cross-section
1
Flat seal
2
Valve body
3
Valve ball
4
Valve seat
5
Valve cap
Technical personnel
1
2
3
4
5
P_SI_0013_SW