Assembly
f
1
f
f
3
Fig. 14: Clearance (f)

6.3 Fastening

Liquid end alignment
m
m
Fig. 15: Dimensions (m)

6.4 Mounting the HMI user control

26
1
Discharge valve
2
Dosing head
2
3
Suction valve
Ensure there is sufficient clearance (f) around the dosing head as well as
the suction and discharge valve so that maintenance and repair work can
be carried out on these components.
P_MOZ_0017_SW
Dosing rate too low.
The valves of the liquid end cannot close correctly if the valves of the
liquid end are not upright.
Ensure that the discharge valve is upright.
n
Vibrations can disturb the liquid end valves.
Secure the metering pump so that no vibrations can occur.
n
Take the dimensions (m) for the fastening holes from the appropriate
dimensional or data sheets.
DN
Use appropriate screws to fix the pump base to the foundation.
P_MOZ_0015_SW
You can mount the HMI on a wall if the pump has been ordered with a wall
fixing.
Install the HMI in the direct vicinity of the pump. If that is not provided for,
then you will need to fit a circuit breaker there. When doing so, consider
the available cable length.
Refer to the relevant dimensional drawing for the dimensions of the HMI
and the fixing holes.
CAUTION!
Warning of faulty operation
Do not install the HMI and the cable too close to
equipment and cabling that emit strong electrical
interference.