Technical data
16.2

Viscosity

Tab. 13: The liquid ends are suitable for the following viscosity ranges:
Design
Standard
With valve springs
With valve springs and suction-
side feed
16.3

Shipping weight

Types
16050; 10090; 16130
07120; 07220; 04350
16.4

Wetted materials

Material ver‐
Liquid end
sion
PVT
PVDF
SST
Stainless steel
1.4404
16.5

Ambient conditions

16.5.1

Ambient temperatures

Pump, compl.
16.5.2

Media temperatures

PVT liquid end
84
Stroke rate, max.
Strokes/min
200
130
90
Material version
Suction/pres‐
Seals* / ball
sure connector
seat
PVDF
PTFE / PTFE
Stainless steel
PTFE / PTFE
1.4581
* Diaphragm is PTFE-coated.
** with types 07120, 07220, 04350.
Data
Storage and transport temperature
Ambient temperature in operation (drive +
motor):
Data
Max. temperature long-term at max. oper‐
ating pressure
Max. temperature for 15 min at max. 2 bar
Viscosity
mPas
0 ... 200
200 ... 500
500 ... 1000*
* Only when the installation is correctly adjusted.
Shipping weight
PVT
SST
PVT
SST
Balls
Springs
Ceramic /
Hastelloy C
glass **
Stainless steel
Hastelloy C
1.4404
kg
17.2
20.0
18.8
24.8
Integral relief
valve
PVDF / FPM
or EPDM
Stainless
steel / FPM or
EPDM
Value Unit
-10 ... +50 °C
-10 ... +45 °C
Value Unit
65 °C
100 °C

Hide quick links: