Diaphragm Rupture Sensor - ProMinent Sigma X Operating Instructions Manual

Diaphragm motor-driven metering pump
Hide thumbs Also See for Sigma X:
Table of Contents

Advertisement

Technical data
16.8

Diaphragm rupture sensor

Contact (standard)
Tab. 15: Contact loading, max.
at voltage
30 V DC
Namur sensor (Specified for EX zones)
Specification
Nominal voltage *
Power consumption - active surface uncovered
Power consumption - active surface covered
Rated switching distance
86
Data
Output
Max. starting current
Electrical data at 100 V
Data
Effective current
Switch on peak current, (for approx. 100
ms)
Electrical data at 230 V
Data
Effective current
Switch on peak current, (for approx. 100
ms)
* internal switchover
Tab. 14: Fuses
Fuse
Fuse, internal
INFORMATION!: Only use the original ProMinent fuses. It is not sufficient
to use a fuse with the above fuse rating.
Maximum current
1 A
The contact is an opener.
The contact is an potential-free.
5–25 V DC, in accordance with Namur or DIN 60947-5-6, potential-free
design.
* Ri ~ 1 kΩ
Value
6.3 AT - (1.5 kA)
For safety reasons we recommend connecting to a
protective low voltage, e.g. in accordance with EN
60335-1 (SELV ).
The cable can be poled as required.
Value
8 V DC
> 3 mA
< 1 mA
1.5 mm
Value Unit
220 W
8.5 A
Value Unit
3.3 A
4 A
Value Unit
1.5 A
8 A
Order no.
732379