'Operating mode'

9.3.1
'Manual'
9.3.1.1
'Batch'
9.3.1.2
Memory - remaining strokes not yet pro‐
cessed
'Contact'
9.3.1.3
'Menu / Information è Settings è Operating mode è ...'
'Menu / Information è Settings è Operating mode è Manual'
'Manual' operating mode allows you to operate the pump manually.
The stroke rate can be set in the continuous display of this operating
mode.
'Menu / Information è Settings è Operating mode è Batch è ...'
'Batch' operating mode enables you to pre-select large metering vol‐
The
umes.
You can only select whole numbers but no fractions as the number of
strokes (figures 1 to 99,999).
You can trigger the strokes using the
'Push' continuous display. You can also trigger them via a
switched to the
pulse using the "External control" terminal.
You can also activate the
'Memory' function extension ("memory" identi‐
'Memory' is activated, the pump adds up the remaining
fier ). When
strokes, which could not be processed, up to the maximum capacity of the
stroke memory of 99,999 strokes. If this maximum capacity is exceeded,
the pump goes into fault mode.
CAUTION!
The pump maintains its stroke rate when changing
'Manual' operating mode to 'Batch' oper‐
over from
ating mode.
When you press
function is activated, the
'Menu / Information è Settings è Operating mode è Contact
...'
è
'Contact' operating mode allows you to trigger individual strokes or a
series of strokes.
You can trigger the strokes via a pulse sent via the "External control" ter‐
minal.
The purpose of this operating mode is to convert the incoming pulses into
strokes with a step-down (fractions) or small step-up.
CAUTION!
The pump maintains the stroke rate when changing over
'Manual' operating mode to 'Contact' operating
from
mode.
Set up/
[Clickwheel] if you have already
[STOP/START] or the "Pause"
'Memory' is cleared.
'Menu'