Operating Mode - ProMinent DULCO flex Control-DFYa Operating Instructions Manual

Peristaltic metering pump
Table of Contents

Advertisement

'Menu'
Set up /

'Operating mode'

12.2.1
'Manual'
12.2.1.1
'Contact'
12.2.1.2
Memory - Pulses not yet processed
Contact water meter
'Batch'
12.2.1.3
48
'Menu / Information è Operating mode è ...'
'Menu / Information è Operating mode è Manual'
'Manual' operating mode lets you operate the pump manually.
The capacity can be set in the continuous displays of this operating mode.
The minimum volume that can be metered corresponds to 1 revolution of
the rotor.
'Menu / Information è Operating mode è Contact è ...'
'Contact' operating mode allows you to meter pre-set metering vol‐
The
umes.
You can trigger metering via a pulse sent via the "External control" socket.
The purpose of this operating mode is to convert the incoming pulses into
a pre-settable metering volume.
CAUTION!
The pump maintains the capacity when changing over
'Manual' operating mode to 'Contact' operating
from
mode.
The maximum capacity can be set in 'Contact' operating
mode.
The minimum volume that can be metered corresponds to 1 revolution of
the rotor.
'Memory' function extension ("memory" identi‐
You can also activate the
'Memory' is activated, the pump adds up the remaining vol‐
fier). When
umes, which could not be processed, up to the maximum capacity of the
memory of 99,999 l. If this maximum capacity is exceeded, the pump goes
into fault mode.
CAUTION!
Only with
'Memory' - 'off' : If you press
[STOP/START] or empty the contact memory
'Menu / Information è Service è Clear counters' )
(
or the "Pause" function is activated, the
cleared.
Using "Pulse control" you can ideally adapt the pump to the relevant
process, for example in conjunction with contact water meters.
'Menu / Information è Operating mode è Batch è ...'
'Memory' is