Table of Contents

Advertisement

Installation

Testing

3 The panel ID menu has a numeric "keypad" with which you can enter a new panel ID:
The panel shows the current panel ID on the top left button of the right-hand button
matrix. It shows the panel ID you are entering in the third display (labeled
'Destination').
If you make a mistake, press 'Clear' to erase your entry and start over.
When you have entered a panel ID correctly, press 'Save' .
Press 'Exit' at any time to leave the panel ID menu. You might have to press 'Exit' more
than once to leave the menu entirely.
4 After you enter the panel ID, reconnect the Ethernet cable. The NV9000 system
controller can detect your panel in a few seconds. But it will do so only when the
NV9000 has a panel configuration defined for this panel ID.
(All panel IDs must be unique.)
You can now prepare an NV9649 configuration in NV9000-SE Utilities and upload the
configuration to the NV9000. You need the panel ID to create a NV9649 configuration.
When you upload the configuration, the panel ID you entered in NV9000-SE Utilities
designates the actual panel to which the upload will occur. If no actual panel has that ID,
the upload cannot occur.
When you restart the NV9000 system controller with the appropriate panel configuration,
the NV9649 you have configured should become active. Its buttons and displays will turn
on, showing meaningful data.

Testing

A panel test function is available when the NV9649 is disconnected from the system
controller. Run the test to determine the health of your NV9649. See
page 125 for detail. You can also view the software version numbers under setup mode.
These are points to consider after you install your NV9649 control panel(s):
1 Do the buttons illuminate? When an NV9649 powers up, one or more of its buttons are
supposed to turn green or amber. Does it pass the panel test mentioned above?
2 When the NV9649 powers up and it is connected to the system controller, it should
initialize completely. (That takes a few seconds.) The NV9000 system should load
whatever configuration exists for that panel and the buttons appropriate for its
configuration should light.
If you continue to see "No Server, " "ACQ IP, " or "Locating Network, " you have a problem.
Reboot everything and try again.
14
N V 9 6 4 9
1 1
2 2
3 3
P a n e l I D
4 4
5 5
6 6
_ _ _ _ _ 1 2 3
7 7
8 8
9 9
0 0
PANEL ID
PANEL ID
6491
6491
CLEAR
CLEAR
SAVE
SAVE
EXIT
EXIT
Setup Mode
on

Advertisement

Table of Contents
loading

Table of Contents