Table of Contents

Advertisement

Configuration
Selection Buttons
Note that the maximum number of MD destinations is configured in multiples 8, from 8
to 512.
Populating the MD Device List
The 'Edit Multi-Destination Device' button appears when you are configuring a selection
button. Click this button to get the 'Multi-Destination Entry' window. The window presents
a list of all destinations on the left and a set of MD devices at the right. The MD device set is
initially empty and becomes populated as you add destination devices from the left. You
can add devices in any order. The order is preserved and is the order in which the MD
devices appear on the selection buttons under scrolling.
See
Multi-Destination

Selection

XY Mode — Normal
When the operator selects a destination, all selection buttons that have levels defined for
the destination turn on (high-tally). The operator may select or deselect any levels as
required, by pressing selection buttons and perhaps scrolling the display.
Note that if the operator selects a level when all levels are on, all the other levels
become unselected (low-tally).
Selecting a new destination again turns on all selection buttons that have levels defined.
Source/Destination buttons are "all level"— not subject to level selection.
XY Mode — Hold Mode
In hold mode, when the operator selects a destination, previously deselected levels
(defined for the destination) remain selected for additional takes and previously unse-
lected levels remain deselected. (Individual levels turn on or off as the user selects
them.)
MD Mode — Normal
When the user selects an MD device, all selection buttons are mutually exclusive: when
the operator presses one button, any others that were selected turn off. To perform MD
takes, the operator alternately selects an MD device and then a source until all intended
devices have been preset. Then the operator presses 'Take' .
(In normal mode, any selected MD devices become unselected after the take.)
MD Mode — Hold Mode
In hold mode, selection buttons are not mutually exclusive. To perform MD takes, the
operator selects one or more MD devices. All of them turn on (high-tally). The operator then
selects a source (which becomes preset for all the selected devices).
The operator can preset another source to another set of destinations by deselecting
selected destinations, selecting other destinations, and selecting another source.
When all intended destinations are preset, the operator then presses 'Take' .