Ricoh PRIPORT VT 2000 Series Service Manual page 112

Table of Contents

Advertisement

[G]
After the master eject process is finished, the master eject motor [A] turns
clockwise, driving the gear [B] clockwise through the relay gears.
When the pin [C] of the gear [B] turns about 45 degrees, the pressure plate
goes down immediately due to the one-way clutch in the gear [D] and the
pressure spring [E]. Therefore, the ejected master in the master eject box is
compressed by the pressure plate [F].
If the full master detecting switch [G] does not turn on when the pressure
plate goes down, this means that the master eject box is filled with ejected
masters. In this case, the "F" and
stops after a new master is wrapped.
The "F" and
turned OFF and ON. This is to prevent the full ejected master condition
from being reset without removing the ejected master from the box.
NOTE:
The VT2100/VT2130/VT2150 use a gear instead of a timing belt
[H]. (See page 2-79.)
[E]
indicators cannot be reset until the master box switch is
[F]
[B]
[C]
indicators blink, and the machine
2-85
28 February '91
[A]
[H]
[D]