6.2 PRESSURE PLATE POSITION SWITCH ADJUSTMENT
Purpose: To ensure that the pressure plate stops at the proper position.
1. Open the master eject unit and remove the front cover of the master eject
unit (3 screws).
2. Turn the gear [A] and position the pressure plate [B] at the maximum
height.
3. Confirm that the distance between the switch [C] and lever [D] is 0.1 to
0.5 mm when the lever edge [E] is positioned in the ditch on the cam [F]
bottom.
Also, confirm that the switch turns off when the lever edge [E] is not
positioned in the ditch on the cam [F] bottom.
4. If it is out of adjustment, loosen the screws [G] and adjust the mounting
position of the pressure plate position switch.
[F]
[E]
[C]
[G]
5-32
[B]
[A]
[D]
0.1 ~ 0.5 mm
[C]