Ricoh MP C6502SP System Maintenance
Ricoh MP C6502SP System Maintenance

Ricoh MP C6502SP System Maintenance

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

Model CH-C1
Machine Code:
D135/D136/D137/D138
System Maintenance 2
23 May, 2014

Advertisement

Table of Contents
loading

Summary of Contents for Ricoh MP C6502SP

  • Page 1 Model CH-C1 Machine Code: D135/D136/D137/D138 System Maintenance 2 23 May, 2014...
  • Page 3: Revision History

    Revision History Version Revision Date Revision History V1.00 2013.05.13 V2.00 2014.05.23 See page 1 "Revision History (V2.00)" . Revision History (V2.00) Chapter Items 3. Main SP Tables-5 SP5-009 to 721 (Mode): SP5507-006 SP5-722 to 998 (Mode): SP5801 (Clear Memory) SP5-722 to 998 (Mode): SP5985 (Device Setting) SP5-722 to 998 (Mode): SP5895 (Application invalidation) 7.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS Revision History..............................1 Revision History (V2.00)..........................1 1. Main SP Tables-3 SP3-XXX (Process)...............................5 2. Main SP Tables-4 SP4-XXX (Scanner)............................91 3. Main SP Tables-5 SP5-009 to 721 (Mode)..........................189 SP5-722 to 998 (Mode)..........................277 4. Main SP Tables-6 SP6-XXX (Peripherals)........................... 361 5.
  • Page 5 Downloading Stamp Data........................831 Updating Java VM............................832 Creating an SD Card for Updating......................832 Updating Procedure..........................832 List of Error Messages..........................833 Updating the EXJS............................836 To Update EXJS............................836 When checking the version of EXJS......................838 Package Firmware Update (D135/D136 only)..................840 Overview..............................840 Immediate Update.............................841 Update at the Next Visit (Reserve)......................
  • Page 7: Main Sp Tables-3

    1. Main SP Tables-3 SP3-XXX (Process) 3011 [Manual ProCon :Exe] [- / - / -] Normal ProCon [Execute] Executes Process Control [- / - / -] Density Adjustment [Execute] Executes Density Adjustment Process Control. [- / - / -] ACC RunTime ProCon [Execute] Executes ACC Run Time Process Control.
  • Page 8 1. Main SP Tables-3 History:3Times Before *ENG [0 to 99999999 / 0 / 1/step] Displays the third latest Process Control execution result. History:4Times Before *ENG [0 to 99999999 / 0 / 1/step] Displays the forth latest Process Control execution result. History:5Times Before *ENG [0 to 99999999 / 0 / 1/step]...
  • Page 9 SP3-XXX (Process) Out of range from ID Sensor Vsg adjust error Vsg=4.0±x.x[V/step] ID Sensor LED Adjust error Ifsg>Max ID Sensor Output error(Positive Vsg_reg<Min(Max) reflect) 20 and lager ID Sensor output error(Diffusion ID Sensor Vsg_dif<Min(Max) reflect) ID Sensor offset Voltage Voffset_reg>Max error(Positive reflect) ID Sensor offset Voltage Voffset_dif>Max...
  • Page 10 1. Main SP Tables-3 LD won’t light P patter is not written. Residual potential:Vr error Vr>Max 60 and lager Electrified potential:Vd adjust Vd can not be adjusted in target Potential adjust error range. Exposure potential:Vpl adjust Vpl can not be adjusted in error target range Potential control method is set...
  • Page 11 SP3-XXX (Process) [- / - / -] Execute: COL [Execute] Executes when filling Developer. (the mode filling Development Unit with Developer) [- / - / -] Execute: K [Execute] Executes when filling Developer. (the mode filling Development Unit with Developer) [- / - / -] Execute: C [Execute]...
  • Page 12 1. Main SP Tables-3 [- / - / -] Execute: ALL [Execute] Executes TD Sensor Initial setting for all colors. [- / - / -] Execute: COL [Execute] Executes TD Sensor Initial setting for only three colors. [- / - / -] Execute: K [Execute] Executes TD Sensor Initial setting for only (K).
  • Page 13 SP3-XXX (Process) 001 Execute: ALL 002 Execute: COL 003 Execute: K [- / - / -] [Execute] 004 Execute: C 005 Execute: M 006 Execute: Y A4 Page Cover [0 to 100 / 6 / 1page/step] Sets the number of A4 full coverage pages creating when setting Cleaning Initial setup. [DEMS:Execute] 3040 Measures M/A patch.
  • Page 14 1. Main SP Tables-3 001 ALL 002 K [- / - / -] 003 C [Execute] 004 M 005 Y [DEMS:Phasing:Exe OK?] 3043 Displays the result of DEMS Phasing Mode. [00000000 to 99999999 / 001 From Left:YYMMCCKK 00000000 / 1/step] [Force Tnr Supply :Exe] 3050 Supplies toner forcibly.
  • Page 15 SP3-XXX (Process) [Manual Toner Fill :Exe] 3051 Executes Toner Fill. [- / - / -] 001 EXECUTE:ALL [Execute] [Pot.Sens Check :Exe] 3070 Executes Potential Sensor Check. (For checking when assembling in the factory and for confirming when failure occurs in the market.) [- / - / -] 001 Execute [Execute]...
  • Page 16 1. Main SP Tables-3 Vr:Y [0 to 999 / 0 / 1-V/step] Displays Potential Sensor Check Result: Vr (Y). Voffset:K [0 to 999 / 0 / 1-V/step] Displays Potential Sensor Check Result: Voffset (K). Voffset:C [0 to 999 / 0 / 1-V/step] Displays Potential Sensor Check Result: Voffset (C).
  • Page 17 SP3-XXX (Process) [Toner Status :Disp] 3101 Displays Toner Status (K) on a scale of one to ten. 001 K *ENG [0 to 10 / 10 / 1/step] 10: Full 002 C *ENG 2: Estimate Near End 003 M *ENG 1: Fixed Near End 004 Y *ENG 0: Toner End...
  • Page 18 1. Main SP Tables-3 [0.0 to 99999999.0 / 0.0 / 0.1mg/ mg Remains:Y *ENG step] Displays Toner Remains (Y) in mg. [0.0 to 99999999.0 / 0.0 / 0.1mg/ 021 Tnr mg (NewBtl):K *ENG step] [0.0 to 99999999.0 / 0.0 / 0.1mg/ 022 Tnr mg (NewBtl):C *ENG step]...
  • Page 19 SP3-XXX (Process) [0.0 to 99999999.0 / 0.0 / 0.1mg/ 053 Feed Counter:M *ENG step] [0.0 to 99999999.0 / 0.0 / 0.1mg/ 054 Feed Counter:Y *ENG step] 3110 [TNE Detect(Lvl1) :Set] ON/OFF *ENG [0 to 1 / 0 / 1/step] Sets whether to display Toner Near End (Level 1) on the operation panel. Disp Timing:K *ENG [10 to 100 / 10 / 1%/step]...
  • Page 20 1. Main SP Tables-3 Cnt:M *ENG [0 to 255 / 0 / 1count/step] Displays how many times Toner End Sensor (M) continuously detects Toner Empty. Cnt:Y *ENG [0 to 255 / 0 / 1count/step] Displays how many times Toner End Sensor (Y) continuously detects Toner Empty. 3130 [TE Detect :Set] Set Sheets(Min)
  • Page 21 SP3-XXX (Process) Pxl Cnt:M *ENG [0 to 1000000 / 0 / 1cm2/step] Displays how many square centimeters of toner are consumed in M coverage after Toner Near End is fixed. Pxl Cnt:Y *ENG [0 to 1000000 / 0 / 1cm2/step] Displays how many square centimeters of toner are consumed in Y coverage after Toner Near End is fixed.
  • Page 22 1. Main SP Tables-3 3152 [Bottle Motor :Set] On Time *ENG [- to - / 400 / 1count/step] Displays how many times Toner Fill Operation is executed by Toner Bottle Motor (Y) after Toner Near End is fixed. Off Time *ENG [- to - / 400 / 1count/step] Displays how many times Toner Fill Operation is executed by Toner Bottle Motor (Y) after...
  • Page 23 SP3-XXX (Process) [TnrDensity] 3201 Sets Upper Limit Toner Density (wt%) for Toner Density Control Area. 001 Upper TC *ENG [1.0 to 15.0 / 9.5 / 0.1wt%/step] 002 Lower TC *ENG [1.0 to 15.0 / 4.0 / 0.1wt%/step] [TD.Sens:Vt :Disp] 3210 Displays the latest TD Sensor Output 001 Current: K *ENG...
  • Page 24 1. Main SP Tables-3 Current: M *ENG [0.00 to 5.00 / 2.70 / 0.01V/step] Current TD Sensor Output Voltage Target Value: Displays/Sets Vtref (M). Current: Y *ENG [0.00 to 5.00 / 2.70 / 0.01V/step] Current TD Sensor Output Voltage Target Value: Displays/Sets Vtref (Y). 3232 [Vtref Correct:Pixel] ON/OFF...
  • Page 25 SP3-XXX (Process) Latest:K *ENG [0.00 to 100.00 / - / 0.01%/step] Displays Dot Coverage (K) in the latest page. Latest:C *ENG [0.00 to 100.00 / - / 0.01%/step] Displays Dot Coverage (C) in the latest page. Latest:M *ENG [0.00 to 100.00 / - / 0.01%/step] Displays Dot Coverage (M) in the latest page.
  • Page 26 1. Main SP Tables-3 DC Avg.:L:C *ENG [0.00 to 100.00 / - / 0.01%/step] Displays Dot Coverage DC Average: L (C). DC Avg.:L:M *ENG [0.00 to 100.00 / - / 0.01%/step] Displays Dot Coverage DC Average: L (M). DC Avg.:L:Y *ENG [0.00 to 100.00 / - / 0.01%/step] Displays Dot Coverage DC Average: L (Y).
  • Page 27 SP3-XXX (Process) Environ:Recent *ENG [- / - / -] Displays the current environment according to the absolute humidity calculated by Temperature/Humidity Sensor (Main Unit). Environ:Recent 2 [- / - / -] Displays the current environment according to the absolute humidity calculated by Temperature/Humidity Sensor (Main Unit).
  • Page 28 1. Main SP Tables-3 [0.00 to 100.00 / 25.00 / 005 Abs Humid:5 *ENG 0.01g/m3/step] [Env Thresh:Body] 3265 Sets Absolute Humidity Threshold in order to determine the current environment division based on the detection result of Temperature/Humidity Sensor (Main Unit). [0.00 to 63.00 / 2.50 / 0.01g/m3/ 001 Abs Humid:1 *ENG...
  • Page 29 SP3-XXX (Process) [0.000 to 1.000 / 0.150 / M/A(Target):K *ENG 0.001mg/cm2/step] Displays ID Pattern Target M/A (K). [0.000 to 1.000 / 0.433 / M/A(Target):C *ENG 0.001mg/cm2/step] Displays ID Pattern Target M/A (C). [0.000 to 1.000 / 0.433 / M/A(Target):M *ENG 0.001mg/cm2/step] Displays ID Pattern Target M/A (M).
  • Page 30 1. Main SP Tables-3 [0.000 to 1.000 / 0.000 / M/A(Latest):C *ENG 0.001mg/cm2/step] Displays the latest ID Pattern M/A (C). [0.000 to 1.000 / 0.000 / M/A(Latest):M *ENG 0.001mg/cm2/step] Displays the latest ID Pattern M/A (M). [0.000 to 1.000 / 0.000 / M/A(Latest):Y *ENG 0.001mg/cm2/step]...
  • Page 31 SP3-XXX (Process) [0.000 to 1.000 / 0.600 / M/A UppErr:K 0.001mg/cm2/step] Sets Error Judgment Threshold (K) for SC380 ID Pattern Error. [0.000 to 2.000 / 1.200 / M/A UppErr:Col 0.001mg/cm2/step] Sets Error Judgment Threshold (CMY) for SC381-SC383 ID Pattern Error. [0.000 to 1.000 / 0.100 / M/A LowErr:K 0.001mg/cm2/step]...
  • Page 32 1. Main SP Tables-3 Voffset_dif *ENG [0.00 to 5.50 / 0.00 / 0.01V/step] Displays Diffuse Reflection Output Voltage when ID Sensor LED is turned off. Voffset_TM (Front) *ENG [0.00 to 5.50 / 0.00 / 0.01V/step] Displays Regular Reflection Output Voltage when TM_Front Sensor LED is turned off. Voffset_TM (Center) *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]...
  • Page 33 SP3-XXX (Process) Vsg_reg *ENG [0.00 to 5.50 / 0.00 / 0.01V/step] Displays Regular Reflection Output of bare part of the belt adjusted by Vsg. Vsg_dif *ENG [0.00 to 5.50 / 0.00 / 0.01V/step] Displays Diffuse Reflection Output of bare part of the belt adjusted by Vsg. Vsg_TM (Front) *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]...
  • Page 34 1. Main SP Tables-3 [Vsg Adj OK?] Displays Vsg Adjustment Execution Result. (SP is assigned to be compatible with common model series) • Left digit: TM/P sensor (R) • Right digit: TM/P sensor (L) Displays result by each sensor from left in R, then L order. Code Result detail...
  • Page 35 SP3-XXX (Process) [0.0000 to 5.0000 / 0.3240 / K2(Latest) *ENG 0.0001/step] Displays the latest value of Sensitivity Correction Coefficient: K2 of ID sensor. [0.0000 to 5.0000 / 2.5600 / K5(Latest) *ENG 0.0001/step] Displays the latest value of Sensitivity Correction Coefficient: K5 of ID sensor. [ID.Sens Coef :Set] 3331 Shipping inspection value of ID/TM Sensor indicated on the bar code.
  • Page 36 1. Main SP Tables-3 001 K 002 C [0 to 100 / 5 / 1%/step] 003 M 004 Y [ImgQltyAdj :ON/OFF] 3500 001 ALL *ENG [0 or 1 / - / 1] 002 Process Control *ENG [0 or 1 / - / 1] 003 MUSIC *ENG [0 or 1 / - / 1]...
  • Page 37 SP3-XXX (Process) Rel Humidity *ENG [0 to 100 / 0 / 0.1%RH/step] Displays Drum Stop Environment (Relative Humidity). Abs Humidity *ENG [0 to 99 / 0 / 0.1g/m3/step] Displays Drum Stop Environment (Absolute Humidity). 3529 [ProCon Interval Control :Set] Gamma Corr *ENG [0 to 1 / 1 / 1/step] Sets ON/OFF for Gamma Correction for ProCon Interval Control.
  • Page 38 1. Main SP Tables-3 Relative Humidity Range *ENG [0 to 99 / 50 / 1%RH/step] Sets ProCon Execution Judgment Threshold when the power is ON. Absolute Humidity Range *ENG [0 to 99 / 6 / 1g/m3/step] Sets ProCon Execution Judgment Threshold when the power is ON. Interval:BW *ENG [0 to 5000 / 0 / 1page/step]...
  • Page 39 SP3-XXX (Process) Corr(Mid):BW *ENG [0.00 to 1.00 / 1.00 / 0.01/step] Sets Correction Coefficient (Mid) for Page Interval for Interruption ProCon (BW). Interval:Set:FC *ENG [0 to 5000 / 0 / 1page/step] Sets Interruption ProCon (FC) Page Interval. Interval:Disp:FC *ENG [0 to 5000 / 0 / 1page/step] Displays Interruption ProCon (FC) Page Interval.
  • Page 40 1. Main SP Tables-3 Corr(Mid):FC *ENG [0.00 to 1.00 / 1.00 / 0.01/step] Sets Correction Coefficient (Mid) for Page Interval for Job End ProCon (FC). 3539 [Dev Agitating Time :Set] Time *ENG [0 to 3000 / 0 / 1sec/step] Sets Developer Agitating Time. ON/OFF(by AbsHum) *ENG [0 to 1 / 1 / 1/step]...
  • Page 41 SP3-XXX (Process) [0.00 to 655.35 / 0.00 / 0.01sec/ Required Expel Time:C step] Displays Required Expel Time:C. [0.00 to 655.35 / 0.00 / 0.01sec/ Required Expel Time:M step] Displays Required Expel Time:M. [0.00 to 655.35 / 0.00 / 0.01sec/ Required Expel Time:Y step] Displays Required Expel Time:Y.
  • Page 42 1. Main SP Tables-3 [Chrg AC Control] 3610 Displays Charge AC Control Value determined by Charge AC Control. 001 Std Speed: K *ENG 002 Std Speed: C *ENG [0.00 to 3.00 / 2.20 / 0.01kV/step] 003 Std Speed: M *ENG 004 Std Speed: Y *ENG [Chrg DC Control]...
  • Page 43 SP3-XXX (Process) 102 Procon:Std Speed: C *ENG [300 to 1000 / 450 / 1-V/step] 103 Procon:Std Speed: M *ENG [300 to 1000 / 550 / 1-V/step] 104 Procon:Std Speed: Y *ENG [300 to 1000 / 550 / 1-V/step] 111 Procon:Mid Speed: K *ENG [300 to 1000 / 450 / 1-V/step] 112 Procon:Mid Speed: C...
  • Page 44 1. Main SP Tables-3 021 Low Speed: K *ENG [200 to 800 / 350 / 1-V/step] 022 Low Speed: C *ENG [200 to 800 / 350 / 1-V/step] 023 Low Speed: M *ENG [200 to 800 / 450 / 1-V/step] 024 Low Speed: Y *ENG [200 to 800 / 450 / 1-V/step]...
  • Page 45 SP3-XXX (Process) [LD Power Control] 3613 Displays LD Power determined by ProCon. 001 Std Speed: K *ENG [60 to 180 / 90 / 1%/step] 002 Std Speed: C *ENG [60 to 180 / 90 / 1%/step] 003 Std Speed: M *ENG [60 to 180 / 95 / 1%/step] 004 Std Speed: Y...
  • Page 46 1. Main SP Tables-3 Maximum M/A Adj.:M *ENG [-5 to 5 / 0 / 1/step] Sets Maximum M/A Adj. (M) [Operator Adjustment Item]. Maximum M/A Adj.:Y *ENG [-5 to 5 / 0 / 1/step] Sets Maximum M/A Adj. (Y) [Operator Adjustment Item]. [-0.150 to 0.150 / 0.000 / Maximum M/A Corr:K *ENG...
  • Page 47 SP3-XXX (Process) [0.250 to 0.750 / 0.600 / Procon:Maximum M/A:Y *ENG 0.001mg/cm2/step] Sets Coverage M/A (Y) Current Value according to paper. [0.250 to 0.750 / 0.378 / Plain:Maximum M/A:K *ENG 0.001mg/cm2/step] Sets Coverage M/A (K) Current Value for plain paper. [0.250 to 0.750 / 0.433 / Plain:Maximum M/A:C *ENG...
  • Page 48 1. Main SP Tables-3 Current: K *ENG [0 to 800 / 0 / 1V/step] Displays Development Potential: Current Value (K). Current: C *ENG [0 to 800 / 0 / 1V/step] Displays Development Potential: Current Value (C). Current: M *ENG [0 to 800 / 0 / 1V/step] Displays Development Potential: Current Value (M).
  • Page 49 SP3-XXX (Process) LowerLimit:C *ENG [0 to 400 / 200 / 1V/step] Sets Development Potential (Lower Limit) (C). LowerLimit:M *ENG [0 to 400 / 200 / 1V/step] Sets Development Potential (Lower Limit) (M). LowerLimit:Y *ENG [0 to 400 / 200 / 1V/step] Sets Development Potential (Lower Limit) (Y).
  • Page 50 1. Main SP Tables-3 Line Width Adj.:K *ENG [-5 to 5 / 0 / 1/step] Sets Line Width Adj. (K) [Operator Adjustment Item]. Line Width Adj.:C *ENG [-5 to 5 / 0 / 1/step] Sets Line Width Adj. (C) [Operator Adjustment Item]. Line Width Adj.:M *ENG [-5 to 5 / 0 / 1/step]...
  • Page 51 SP3-XXX (Process) [0.10 to 6.00 / 0.10 / 0.01 mg/ Current: Y *ENG cm2/-kV/step] Displays the latest Development gamma (Y). [0.50 to 2.55 / 0.50 / 0.01 mg/ Target:K *ENG cm2/-kV/step] Displays Target Value for Development gamma (K). [0.50 to 2.55 / 0.50 / 0.01 mg/ Target:C *ENG cm2/-kV/step]...
  • Page 52 1. Main SP Tables-3 001 K *ENG 002 C *ENG [-300 to 300 / 0 / 1-V/step] 003 M *ENG 004 Y *ENG 3641 [Vd(700) :Disp] Average:K *ENG [0 to 999 / 0 / 1-V/step] Displays the average of one rotation of the drum for the latest OPC Vd (K) (Offset Exposure ON).
  • Page 53 SP3-XXX (Process) Max:Y *ENG [0 to 999 / 0 / 1-V/step] Displays the maximum value of one rotation of the drum for the latest OPC Vd (Y) (Offset Exposure ON). Min:K *ENG [0 to 999 / 0 / 1-V/step] Displays the minimum value of one rotation of the drum for the latest OPC Vd (K) (Offset Exposure ON).
  • Page 54 1. Main SP Tables-3 001 K *ENG 002 C *ENG [0 to 999/ 0 / 1-V/step] 003 M *ENG 004 Y *ENG 3649 [Pattern Pot:] Vl(P5):K *ENG [0 to 999/ 0 / 1-V/step] Displays Vl (P5): (K) of the fifth patch for Graduation Pattern. Vl(P5):C *ENG [0 to 999/ 0 / 1-V/step]...
  • Page 55 SP3-XXX (Process) [0.000 to 0.100 / 0.005 / Abp[1] Lwr Threshold *ENG 0.001mg/cm2/step] Sets Abp[1] Lower Threshold for OPC Cycle of Development Bias. [0.000 to 0.100 / 0.005 / Abd[1] Lwr Threshold *ENG 0.001mg/cm2/step] Sets Abd[1] Lower Threshold for Development Roller Cycle of Development Bias. deltaP_Upp Threshold *ENG [0.0 to 180.0 / 60.0 / 0.1deg/step]...
  • Page 56 1. Main SP Tables-3 [-0.500 to 0.500 / 0.000 / 0.001s/ tadj_c:C *ENG step] Sets tadj_c (K) time for Vc (C). [-0.500 to 0.500 / 0.000 / 0.001s/ tadj_c:M *ENG step] Sets tadj_c (K) time for Vc (M). [-0.500 to 0.500 / 0.000 / 0.001s/ tadj_c:Y *ENG step]...
  • Page 57 SP3-XXX (Process) DEV:Acd[1]:M *ENG [0.0 to 25.5 / 0.0 / 0.1%/step] Displays DEV:Acd[1] for Vc Bias (M). DEV:Acd[1]:Y *ENG [0.0 to 25.5 / 0.0 / 0.1%/step] Displays DEV:Acd[1] for Vc Bias (Y). 3673 [Vc:Amp:Disp] OPC:Acp'[1]:K *ENG [0.0 to 25.5 / 0.0 / 0.1%/step] Displays OPC:Acp'[1] for Vc Bias (K).
  • Page 58 1. Main SP Tables-3 OPC:Pcp[1]:C *ENG [0.0 to 360.0 / 0.0 / 0.1deg/step] Displays OPC:Pcp[1] for Vc Bias (C). OPC:Pcp[1]:M *ENG [0.0 to 360.0 / 0.0 / 0.1deg/step] Displays OPC:Pcp[1] for Vc Bias (M). OPC:Pcp[1]:Y *ENG [0.0 to 360.0 / 0.0 / 0.1deg/step] Displays OPC:Pcp[1] for Vc Bias (Y).
  • Page 59 SP3-XXX (Process) deltaPcd[1]:M *ENG [0.0 to 360.0 / 0.0 / 0.1deg/step] Displays deltaPcd[1] for M/A patch (M). deltaPcd[1]:Y *ENG [0.0 to 360.0 / 0.0 / 0.1deg/step] Displays deltaPcd[1] for M/A patch (Y). 3675 [Vb:Coef:Setting] Sbp[1] *ENG [0.00 to 2.55 / 1.00 / 0.01/step] Sets Frequency Correction Coefficient Sbp[1] for OPC Cycle amplitude of Vb.
  • Page 60 1. Main SP Tables-3 [-0.500 to 0.500 / 0.000 / 0.001s/ tadj_b:M *ENG step] Sets tadj_b (M) time for Vb (M). [-0.500 to 0.500 / 0.000 / 0.001s/ tadj_b:Y *ENG step] Sets tadj_b (Y) time for Vb (Y). 3676 [Vb:Amp:Disp] OPC:Abp[1]:K *ENG [0.0 to 25.5 / 0.0 / 0.1%/step]...
  • Page 61 SP3-XXX (Process) OPC:Abp'[1]:K *ENG [0.0 to 25.5 / 0.0 / 0.1%/step] Displays OPC:Abp'[1] for Vb Bias (K). OPC:Abp'[1]:C *ENG [0.0 to 25.5 / 0.0 / 0.1%/step] Displays OPC:Abp'[1] for Vb Bias (C). OPC:Abp'[1]:M *ENG [0.0 to 25.5 / 0.0 / 0.1%/step] Displays OPC:Abp'[1] for Vb Bias (M).
  • Page 62 1. Main SP Tables-3 DEV:Pbd[1]:K *ENG [0.0 to 360.0 / 0.0 / 0.1deg/step] Displays DEV:Pbd[1] for Vb Bias (K). DEV:Pbd[1]:C *ENG [0.0 to 360.0 / 0.0 / 0.1deg/step] Displays DEV:Pbd[1] for Vb Bias (C). DEV:Pbd[1]:M *ENG [0.0 to 360.0 / 0.0 / 0.1deg/step] Displays DEV:Pbd[1] for Vb Bias (M).
  • Page 63 SP3-XXX (Process) [Manual New Part Set] 3701 Sets Flag for executing Manual New Part Setting. 001 #PCDU:K *ENG [0 to 1 / 0 / 1/step] 003 #K_Development Unit *ENG [0 to 1 / 0 / 1/step] 004 Development: Bk *ENG [0 to 1 / 0 / 1/step] 005 Development Filter:K *ENG...
  • Page 64 1. Main SP Tables-3 035 C_Lubricant Blade *ENG [0 to 1 / 0 / 1/step] 036 Brash Drive Joint:C *ENG [0 to 1 / 0 / 1/step] 037 Gears:C *ENG [0 to 1 / 0 / 1/step] 040 #C_Charge Roller Unit *ENG [0 to 1 / 0 / 1/step] 041 Charge Roller: C...
  • Page 65 SP3-XXX (Process) 073 Development: Y *ENG [0 to 1 / 0 / 1/step] 074 Development Filter:Y *ENG [0 to 1 / 0 / 1/step] 077 #Cleaning Unit: Y *ENG [0 to 1 / 0 / 1/step] 078 Y_Cleaning Blade *ENG [0 to 1 / 0 / 1/step] 079 Y_Lubricant Brush *ENG...
  • Page 66 1. Main SP Tables-3 109 #Paper Transfer Unit *ENG [0 to 1 / 0 / 1/step] 110 Quenching *ENG [0 to 1 / 0 / 1/step] 111 PTR(Paper Transfer Roller) *ENG [0 to 1 / 0 / 1/step] 114 #Fusing *ENG [0 to 1 / 0 / 1/step] 115 #Fusing Unit...
  • Page 67 SP3-XXX (Process) 152 Pick-up Roller-Tray2 *ENG [0 to 1 / 0 / 1/step] 153 Feed Roller:Tray 2:Feeding Roller *ENG [0 to 1 / 0 / 1/step] Feed Roller:Tray 2:Separation *ENG [0 to 1 / 0 / 1/step] Roller 157 #Tray3 Roller Assembly *ENG [0 to 1 / 0 / 1/step] 158 Pick-up Roller-Tray3...
  • Page 68 1. Main SP Tables-3 Feed Roller:A4LCT:Separation *ENG [0 to 1 / 0 / 1/step] Roller 187 #Inserter Feed:Tray 1 *ENG [0 to 1 / 0 / 1/step] 188 Inserter:Tray1:Pick-up *ENG [0 to 1 / 0 / 1/step] 189 Inserter:Tray1:Feed Belt *ENG [0 to 1 / 0 / 1/step] 190 Inserter:Tray1:Separate Roller...
  • Page 69 SP3-XXX (Process) Page Count 1 After Near Full *ENG [0 to 1000000 / 0 / 1page/step] Counts printed pages after Mecha Detection. [0.0 to 10000000.0 / 0.0 / 0.1mg/ Volume Count 1 After Near Full *ENG step] Counts waste toner volume (including printing and adjustment operation) after Mecha Detection.
  • Page 70 1. Main SP Tables-3 [0.0 to 10000000.0 / 480000.0 / 0.1mg/step] Value increase: Upper limit for Waste Toner Volume from Mecha Detection Threshold : Volume Count : full *ENG increases. Value decrease: Upper Limit for Waste Toner Volume from Mecha Detection decreases.
  • Page 71 SP3-XXX (Process) [0.00000 to 1.00000 / 0.00002 / Background M/A *ENG 0.00001 mg/mm2] Background M/A Percentage of Transfer Ratio *ENG [0 to 100 / 81 / 1/step] Percentage of Transfer Ratio Date of detection for near full *ENG [0 to 1 / 0 / 1/step] Displays Date of detection for near full.
  • Page 72 1. Main SP Tables-3 New Unit Conduction Detection *ENG [0 to 9 / 4 / 1/step] Times:Thres4 New Unit Conduction Detection Times Threshold Threshold for Conduction Detection Times until when judged as New Unit Judging as New Unit becomes fast if Conduction Detection Times decreases. Judging as New Unit becomes slow if Conduction Detection Times increases.
  • Page 73 SP3-XXX (Process) Near End Distance:M *ENG [0 to 999999999 / 0 / 1cm/step] OPC Distance (M): Save SP Saves and stores the value for PM Counter when detecting Mecha. Near End Distance:Y *ENG [0 to 999999999 / 0 / 1cm/step] OPC Distance (Y): Save SP Saves and stores the value for PM Counter when detecting Mecha.
  • Page 74 1. Main SP Tables-3 [0 to 1 / 0 / 1/step] New Unit Detection Flag:K *ENG 0: Normal, 1: Detecting New Unit New Unit Detection Flag (K) [0 to 1 / 0 / 1/step] New Unit Detection Flag:C *ENG 0: Normal, 1: Detecting New Unit New Unit Detection Flag (C) [0 to 1 / 0 / 1/step]...
  • Page 75 SP3-XXX (Process) Img Area Thresh:K [0.0 to 25.5 / 1.5 / 0.1%/step] Sets Image Area Threshold for Toner Refresh Mode Bk. Img Area Thresh:C [0.0 to 25.5 / 1.5 / 0.1%/step] Sets Image Area Threshold for Toner Refresh Mode C. Img Area Thresh:M [0.0 to 25.5 / 1.5 / 0.1%/step] Sets Image Area Threshold for Toner Refresh Mode M.
  • Page 76 1. Main SP Tables-3 Between Ptn Stop threshold [0 to 10000 / 30 / 1mm] Sets Between Pattern Stop threshold. Between Pattern stops when the required Refresh amount falls below this threshold. [ProCon Target M/A] *D137/D138 only 3921 Sets Maximum M/A Adj. (K) [Operator Adjustment Item]. 001 Custom Paper 001 [-5 to 5 / 0 / 1/step] 002 Custom Paper 002...
  • Page 77 SP3-XXX (Process) 021 Custom Paper 021 [-5 to 5 / 0 / 1/step] 022 Custom Paper 022 [-5 to 5 / 0 / 1/step] 023 Custom Paper 023 [-5 to 5 / 0 / 1/step] 024 Custom Paper 024 [-5 to 5 / 0 / 1/step] 025 Custom Paper 025 [-5 to 5 / 0 / 1/step] 026 Custom Paper 026...
  • Page 78 1. Main SP Tables-3 047 Custom Paper 047 [-5 to 5 / 0 / 1/step] 048 Custom Paper 048 [-5 to 5 / 0 / 1/step] 049 Custom Paper 049 [-5 to 5 / 0 / 1/step] 050 Custom Paper 050 [-5 to 5 / 0 / 1/step] 051 Custom Paper 051 [-5 to 5 / 0 / 1/step]...
  • Page 79 SP3-XXX (Process) 073 Custom Paper 073 [-5 to 5 / 0 / 1/step] 074 Custom Paper 074 [-5 to 5 / 0 / 1/step] 075 Custom Paper 075 [-5 to 5 / 0 / 1/step] 076 Custom Paper 076 [-5 to 5 / 0 / 1/step] 077 Custom Paper 077 [-5 to 5 / 0 / 1/step] 078 Custom Paper 078...
  • Page 80 1. Main SP Tables-3 099 Custom Paper 099 [-5 to 5 / 0 / 1/step] 100 Custom Paper 100 [-5 to 5 / 0 / 1/step] [ProCon Target M/A] *D137/D138 only 3922 Sets Maximum M/A Adj. (C) [Operator Adjustment Item]. 001 Custom Paper 001 [-5 to 5 / 0 / 1/step] 002 Custom Paper 002...
  • Page 81 SP3-XXX (Process) 022 Custom Paper 022 [-5 to 5 / 0 / 1/step] 023 Custom Paper 023 [-5 to 5 / 0 / 1/step] 024 Custom Paper 024 [-5 to 5 / 0 / 1/step] 025 Custom Paper 025 [-5 to 5 / 0 / 1/step] 026 Custom Paper 026 [-5 to 5 / 0 / 1/step] 027 Custom Paper 027...
  • Page 82 1. Main SP Tables-3 048 Custom Paper 048 [-5 to 5 / 0 / 1/step] 049 Custom Paper 049 [-5 to 5 / 0 / 1/step] 050 Custom Paper 050 [-5 to 5 / 0 / 1/step] 051 Custom Paper 051 [-5 to 5 / 0 / 1/step] 052 Custom Paper 052 [-5 to 5 / 0 / 1/step]...
  • Page 83 SP3-XXX (Process) 074 Custom Paper 074 [-5 to 5 / 0 / 1/step] 075 Custom Paper 075 [-5 to 5 / 0 / 1/step] 076 Custom Paper 076 [-5 to 5 / 0 / 1/step] 077 Custom Paper 077 [-5 to 5 / 0 / 1/step] 078 Custom Paper 078 [-5 to 5 / 0 / 1/step] 079 Custom Paper 079...
  • Page 84 1. Main SP Tables-3 100 Custom Paper 100 [-5 to 5 / 0 / 1/step] [ProCon Target M/A] *D137/D138 only 3923 Sets Maximum M/A Adj. (M) [Operator Adjustment Item]. 001 Custom Paper 001 [-5 to 5 / 0 / 1/step] 002 Custom Paper 002 [-5 to 5 / 0 / 1/step] 003 Custom Paper 003...
  • Page 85 SP3-XXX (Process) 023 Custom Paper 023 [-5 to 5 / 0 / 1/step] 024 Custom Paper 024 [-5 to 5 / 0 / 1/step] 025 Custom Paper 025 [-5 to 5 / 0 / 1/step] 026 Custom Paper 026 [-5 to 5 / 0 / 1/step] 027 Custom Paper 027 [-5 to 5 / 0 / 1/step] 028 Custom Paper 028...
  • Page 86 1. Main SP Tables-3 049 Custom Paper 049 [-5 to 5 / 0 / 1/step] 050 Custom Paper 050 [-5 to 5 / 0 / 1/step] 051 Custom Paper 051 [-5 to 5 / 0 / 1/step] 052 Custom Paper 052 [-5 to 5 / 0 / 1/step] 053 Custom Paper 053 [-5 to 5 / 0 / 1/step]...
  • Page 87 SP3-XXX (Process) 075 Custom Paper 075 [-5 to 5 / 0 / 1/step] 076 Custom Paper 076 [-5 to 5 / 0 / 1/step] 077 Custom Paper 077 [-5 to 5 / 0 / 1/step] 078 Custom Paper 078 [-5 to 5 / 0 / 1/step] 079 Custom Paper 079 [-5 to 5 / 0 / 1/step] 080 Custom Paper 080...
  • Page 88 1. Main SP Tables-3 [ProCon Target M/A] *D137/D138 only 3924 Sets Maximum M/A Adj. (Y) [Operator Adjustment Item]. 001 Custom Paper 001 [-5 to 5 / 0 / 1/step] 002 Custom Paper 002 [-5 to 5 / 0 / 1/step] 003 Custom Paper 003 [-5 to 5 / 0 / 1/step] 004 Custom Paper 004...
  • Page 89 SP3-XXX (Process) 025 Custom Paper 025 [-5 to 5 / 0 / 1/step] 026 Custom Paper 026 [-5 to 5 / 0 / 1/step] 027 Custom Paper 027 [-5 to 5 / 0 / 1/step] 028 Custom Paper 028 [-5 to 5 / 0 / 1/step] 029 Custom Paper 029 [-5 to 5 / 0 / 1/step] 030 Custom Paper 030...
  • Page 90 1. Main SP Tables-3 051 Custom Paper 051 [-5 to 5 / 0 / 1/step] 052 Custom Paper 052 [-5 to 5 / 0 / 1/step] 053 Custom Paper 053 [-5 to 5 / 0 / 1/step] 054 Custom Paper 054 [-5 to 5 / 0 / 1/step] 055 Custom Paper 055 [-5 to 5 / 0 / 1/step]...
  • Page 91 SP3-XXX (Process) 077 Custom Paper 077 [-5 to 5 / 0 / 1/step] 078 Custom Paper 078 [-5 to 5 / 0 / 1/step] 079 Custom Paper 079 [-5 to 5 / 0 / 1/step] 080 Custom Paper 080 [-5 to 5 / 0 / 1/step] 081 Custom Paper 081 [-5 to 5 / 0 / 1/step] 082 Custom Paper 082...
  • Page 92 1. Main SP Tables-3...
  • Page 93: Main Sp Tables-4

    2. Main SP Tables-4 SP4-XXX (Scanner) [Sub Scan Magnification Adj] 4008 Adjusts Sub Scan Magnification by 0.1% each step. [-1.0 to 1.0 / 0.0 / 0.1 %/step] 001 - Picture will stretch as value increases. Picture will shrink as value decreases. [Sub Scan Registration Adj] 4010 Adjusts Sub Scan Registration position of book scanner by 0.1mm each step.
  • Page 94 2. Main SP Tables-4 [Set Scale Mask] Adjusts scanning margins for the leading and trailing edges (sub scan) and right and left edge (main scan). 4012 • Do not adjust unless the customer desires a scanner margin greater than the printer margin.
  • Page 95 SP4-XXX (Scanner) [0 or 1 / 0 / 1/step] Dust Detect:On/Off *ENG 0: OFF 1: ON Sets DF Dust Detection ON/OFF. [0 to 8 / 4 / 1/step] Dust Detect: Lvl *ENG 0: lowest detection level 8: highest detection level Sets DF Dust Detect Level.
  • Page 96 2. Main SP Tables-4 [0 to 15 / 11 / 1/step] Value increase: Tonner adhesion amount will increase for Bk picture 600dpi 2bit edge1 *ENG edge. Toner decrease: Toner adhesion amount will decrease for Bk picture edge. Parameter for smaller edge max. threshold: 600dpi 2bit Adjust towards lowering toner adhesion amount for Bk picture edge.
  • Page 97 SP4-XXX (Scanner) [0 to 15 / 11 / 1/step] Value increase: Tonner adhesion amount will increase for Bk picture 600dpi 4bit edge23 *ENG edge. Toner decrease: Toner adhesion amount will decrease for Bk picture edge. Parameter for larger edge max. threshold: 600dpi 4bit Adjust towards lowering toner adhesion amount for Bk picture edge.
  • Page 98 2. Main SP Tables-4 [0 or 1 / 0 / 1/step] Min Size for APS *ENG 0: No Original 1: A5 SEF Sets display when non-standard (small size) size original is detected. • Sets display when non-standard (small size) size original is detected. •...
  • Page 99 SP4-XXX (Scanner) Original Density Thresh *ENG [0 to 255 / 18 / 1digit/step] Sets scan image density Thresh for Scan size detection. Detection Time *ENG [20 to 100 / 60 / 20msec/step] Sets Detection time for scan size detection. Lamp ON:Delay Time *ENG [40 to 200 / 40 / 10msec/step] Adjusts lamp light timing for scan size detection.
  • Page 100 2. Main SP Tables-4 4351 [Intermittent Shading : FC] [0 or 1 / 1 / 1/step] 1: Intermittent Shading ON Switch On/Off 0: Intermittent Shading OFF(Shad every time) Switches On/OFF for Intermittent Shading when scanning FC (Simplex/Duplex). 4400 [Org Edge Mask] Book:Sub LEdge [0.0 to 3.0 / 0.0 / 0.1 mm/step] Sets mask for original shadow edge 0.1mm per step.
  • Page 101 SP4-XXX (Scanner) 1 256-Gradation main scan A 6 Argyle pattern D 2 Patch 16C 7 Scanned+Slant Grid C 3 Grid pattern A 8 Scanned+Slant Grid D 4 Argyle pattern B 4429 [Select Copy Data Security] Copying *ENG [0 to 3 / 3 / 1/step] Sets illegal copy output pattern density for copy.
  • Page 102 2. Main SP Tables-4 [0 or 1 / 0 / 1/step] GREEN *ENG 0:FL Correction OFF 1:FL Correction ON Switch/Saves ON/OFF of SBU datas (GREEN) FL Correction. With switching ON this SP, when center border area of main scan in image has density left/right difference, reduces it Value adjusted during warranty process of scanner unit is set.
  • Page 103 SP4-XXX (Scanner) Copy:Y:Photo *ENG [0 to 10 / 5 / 1/step] Sets target value for copy AAC of Photo part (non-edge) Yellow plate. 4505 [ACC Cor:Bright] Master:K *ENG [-128 to 127 / 0 / 1/step] Adjusts target value (larger the thinner) for copy AAC of Text (edge) Black plate (Highlight part) depending on setting value (-128 to 127).
  • Page 104 2. Main SP Tables-4 Master:K *ENG [-128 to 127 / 0 / 1/step] Adjusts target value (larger the thinner) for copy AAC of Text (edge) Black plate (Shadow part) depending on setting value (-128 to 127). Master:C *ENG [-128 to 127 / 0 / 1/step] Adjusts target value (larger the thinner) for copy AAC of Text (edge) Cyan plate (Shadow part) depending on setting value (-128 to 127).
  • Page 105 SP4-XXX (Scanner) [0 to 255 / 0 / 1/step] RY Phase: Option *ENG 0:OFF 1:ON Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of R (to Y) Phase. RY Phase: R *ENG [-256 to 255 / 0 / 1/step] Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding R (to Y) Phase.
  • Page 106 2. Main SP Tables-4 [0 to 255 / 0 / 1/step] YG Phase: Option *ENG 0:OFF 1:ON Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of Y (to G) Phase. YG Phase: R *ENG [-256 to 255 / 0 / 1/step] Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding Y (to G)
  • Page 107 SP4-XXX (Scanner) [0 to 255 / 0 / 1/step] GC Phase: Option *ENG 0:OFF 1:ON Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of G (to C) Phase. GC Phase: R *ENG [-256 to 255 / 0 / 1/step] Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding G (to C) Phase.
  • Page 108 2. Main SP Tables-4 [0 to 255 / 0 / 1/step] CB Phase: Option *ENG 0:OFF 1:ON Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of C (to B) Phase. CB Phase: R *ENG [-256 to 255 / 0 / 1/step] Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding C (to B)
  • Page 109 SP4-XXX (Scanner) [0 to 255 / 0 / 1/step] BM Phase: Option *ENG 0:OFF 1:ON Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of B (to M) Phase. BM Phase: R *ENG [-256 to 255 / 0 / 1/step] Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding B (to M) Phase.
  • Page 110 2. Main SP Tables-4 [0 to 255 / 0 / 1/step] MR Phase: Option *ENG 0:OFF 1:ON Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of M (to R) Phase. MR Phase: R *ENG [-256 to 255 / 0 / 1/step] Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding M (to R)
  • Page 111 SP4-XXX (Scanner) [0 to 255 / 0 / 1/step] WHITE: Option *ENG 0:OFF 1:ON Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of highlight area. WHITE:R *ENG [-256 to 255 / 0 / 1/step] Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding highlight area.
  • Page 112 2. Main SP Tables-4 MTF: 0(Off) 1-15 (Weak-Strong) *ENG [0 to 15 / 8 / 1/step] Sets emphasis level for Scan Apli: Text/Chart mode. 0 is for OFF, Larger the value, Stronger the emphasis. Smoothing: 0(x1) 1-7 (Weak- *ENG [0 to 7 / 4 / 1/step] Strong) Sets Smoothing level for Scan Apli: Text/ Chart mode.
  • Page 113 SP4-XXX (Scanner) Contrast: 1-255 *ENG [1 to 255 / 128 / 1/step] Sets Contrast level (1 to 255) for Scan Apli: Text mode. 128 is for No Correction, Larger the value, Stronger the Contrast. Ind Dot Erase: 0(Off) 1-7 (Weak- *ENG [0 to 7 / 0 / 1/step] Strong)
  • Page 114 2. Main SP Tables-4 Smoothing: 0(x1) 1-7 (Weak- *ENG [0 to 7 / 4 / 1/step] Strong) Sets Smoothing level for Scan Apli: Text/Photo mode. 0 is for OFF, Larger the value, the Smoother. Brightness: 1-255 *ENG [1 to 255 / 128 / 1/step] Sets Brightness level (1 to 255) for Scan Apli: Text/Photo mode.
  • Page 115 SP4-XXX (Scanner) Ind Dot Erase: 0(Off) 1-7 (Weak- *ENG [0 to 7 / 0 / 1/step] Strong) Sets Independent Dot Erase level for Scan Apli: Photo mode. 0 is for OFF, Larger the value, Stronger the Erase. 4565 [Scan Apli:GrayScale] MTF: 0(Off) 1-15 (Weak-Strong) *ENG [0 to 15 / 8 / 1/step]...
  • Page 116 2. Main SP Tables-4 Smoothing: 0(x1) 1-7 (Weak- *ENG [0 to 7 / 4 / 1/step] Strong) Sets Smoothing level for Scan Apli: Color Text/Photo mode. 0 is for OFF, Larger the value, the Smoother. Brightness: 1-255 *ENG [1 to 255 / 128 / 1/step] Sets Brightness level (1 to 255) for Scan Apli: Color Text/Photo mode.
  • Page 117 SP4-XXX (Scanner) Ind Dot Erase: 0(Off) 1-7 (Weak- *ENG [0 to 7 / 0 / 1/step] Strong) Sets Independent Dot Erase level for Scan Apli: Color Gloss Photo mode. 0 is for OFF, Larger the value, Stronger the Erase. 4572 [Scan Apli:AutoCol] MTF: 0(Off) 1-15 (Weak-Strong) *ENG...
  • Page 118 2. Main SP Tables-4 Smoothing: 0(x1) 1-7 (Weak- *ENG [0 to 7 / 4 / 1/step] Strong) Sets Smoothing level for FAX Apli: Text/Chart mode. 0 is for OFF, Larger the value, the Smoother. Brightness: 1-255 *ENG [1 to 255 / 128 / 1/step] Sets Brightness level (1 to 255) for FAX Apli: Text/Chart mode.
  • Page 119 SP4-XXX (Scanner) Contrast: 1-255 *ENG [1 to 255 / 128 / 1/step] Sets Contrast level (1 to 255) for FAX Apli: Text mode. 128 is for No Correction, Larger the value, Stronger the Contrast. Ind Dot Erase: 0(Off) 1-7 (Weak- *ENG [0 to 7 / 0 / 1/step] Strong)
  • Page 120 2. Main SP Tables-4 MTF: 0(Off) 1-15 (Weak-Strong) *ENG [0 to 15 / 8 / 1/step] Sets emphasis level for FAX Apli: Photo mode. 0 is for OFF, Larger the value, Stronger the emphasis. Smoothing: 0(x1) 1-7 (Weak- *ENG [0 to 7 / 4 / 1/step] Strong) Sets Smoothing level for FAX Apli: Photo mode.
  • Page 121 SP4-XXX (Scanner) Brightness: 1-255 *ENG [1 to 255 / 128 / 1/step] Sets Brightness level (1 to 255) for FAX Apli: Special Original 1 mode. 128 is for No Correction, Larger the value, the Brighter. Contrast: 1-255 *ENG [1 to 255 / 128 / 1/step] Sets Contrast level (1 to 255) for FAX Apli: Special Original 1 mode.
  • Page 122 2. Main SP Tables-4 SBU_ID [0x00 to 0xFF / 0 / 1/step] Displays SUB ID. In occasions that SUBs ID is not normal cause to a part installed wrong or SUB malfunction, A cause flag will be set to SP4-647-001 and will become SC144-00. SCAT _F_ID [0x00 to 0xFF / 0 / 1/step] Displays SBU (SCAT: F Side) ID.
  • Page 123 SP4-XXX (Scanner) DF Scan *ENG [-384 to 255 / -100 / 1digit/step] Display/Saves Gray Balance Adjustment value (GREEN) of Scanners surface (ADF) Adjusted Value during the warranty process of scan unit is saved. • With DF Density Adjustment value: SP4-688-002, GrayBalance Adjustment value correction is available for when DF reading.
  • Page 124 2. Main SP Tables-4 [0 to 3 / 1 / 1/step] 0:do not adjust SSCG Mode Selection *ENG 1: Only adjust analog.(default) 2: Only adjust digital 3: Adjust both analog/digital. Selects SSCG Noise Correction Mode. Use when SSCG does not function correctly due to accidental malfunction, as a temporally action, set with out adjusting SSCG.
  • Page 125 SP4-XXX (Scanner) Latest:F:BE [-31 to 31 / 0 / 1digit/step] Displays SSCG analog correction value (F Side/BLUE/EVEN pixel). Adjustment will be done when scanner turns on. Use for design evaluation, analyzing malfunction (abnormal images). Latest:F:BO [-31 to 31 / 0 / 1digit/step] Displays SSCG analog correction value (F Side/BLUE/ODD pixel).
  • Page 126 2. Main SP Tables-4 Latest:L:BO [-31 to 31 / 0 / 1digit/step] Displays SSCG analog correction value (L Side/BLUE/ODD pixel). Adjustment will be done when scanner turns on. Use for design evaluation, analyzing malfunction (abnormal images). 4638 [SSCG Noise Cancel (Digital)] Latest:F:RE *ENG [-255 to 255 / 0 / 1digit/step]...
  • Page 127 SP4-XXX (Scanner) Latest:F:BO *ENG [-255 to 255 / 0 / 1digit/step] Displays SSCG Digital correction value (F Side/BLUE/ODD pixel). Adjustment will be done when scanner turns on. Use for design evaluation, analyzing malfunction (abnormal images). Latest:L:RE *ENG [-255 to 255 / 0 / 1digit/step] Displays SSCG Digital correction value (L Side/RED/EVEN pixel).
  • Page 128 2. Main SP Tables-4 4639 [SSCG Noise Cancel (Analog)] Factory :F:RE *ENG [-31 to 31 / 0 / 1digit/step] Display/Saves Factory SSCG Analog correction value (F Side/RED/EVEN pixel). Adjusted SSCG correction Value during the main unit warranty process is saved. Use for analyzing malfunction, comparing factory / current value.
  • Page 129 SP4-XXX (Scanner) Factory :L:RO *ENG [-31 to 31 / 0 / 1digit/step] Display/Saves Factory SSCG Analog correction value (L Side/RED/ODD pixel). Adjusted SSCG correction Value during the main unit warranty process is saved. Use for analyzing malfunction, comparing factory / current value. Factory :L:GE *ENG [-31 to 31 / 0 / 1digit/step]...
  • Page 130 2. Main SP Tables-4 Factory :F:RO [-255 to 255 / 0 / 1digit/step] Display/Saves Factory SSCG Digital correction value (F Side/RED/ODD pixel). Adjusted SSCG correction Value during the main unit warranty process is saved. Use for analyzing malfunction, comparing factory / current value. Factory :F:GE [-255 to 255 / 0 / 1digit/step] Display/Saves Factory SSCG Digital correction value (F Side/GREEN/EVEN pixel).
  • Page 131 SP4-XXX (Scanner) Factory :L:GE [-255 to 255 / 0 / 1digit/step] Display/Saves Factory SSCG Digital correction value (L Side/GREEN/EVEN pixel). Adjusted SSCG correction Value during the main unit warranty process is saved. Use for analyzing malfunction, comparing factory / current value. Factory :L:GO [-255 to 255 / 0 / 1digit/step] Display/Saves Factory SSCG Digital correction value (L Side/GREEN/ODD pixel).
  • Page 132 2. Main SP Tables-4 L:RE [0 to 1023 / 0 / 1digit/step] Displays SSCG Nose Amplitude (L Side/RED/EVEN pixel) when adjusting SSCG. Correction value will be decided depending on detected Noise Amplitude when adjusting. Adjustment will be done when scanner turns on. Use for design evaluation, analyzing malfunction (abnormal images).
  • Page 133 SP4-XXX (Scanner) F:BE [0 to 1023 / 0 / 1digit/step] Displays SSCG Nose Amplitude (F Side/BLUE/EVEN pixel) when adjusting SSCG. Correction value will be decided depending on detected Noise Amplitude when adjusting. Adjustment will be done when scanner turns on. Use for design evaluation, analyzing malfunction (abnormal images).
  • Page 134 2. Main SP Tables-4 [0 to 65535 / 0 / 1/step] Bit15:Unused Bit14: Unused Bit13:White level abnormal (F side/RED/EVEN pixel) Bit12: White level abnormal (F side /RED/ODD pixel) Bit11: White level abnormal (F side / GREEN/EVEN pixel) Bit10: White level abnormal (F side / GREEN/ODD pixel) Bit9: White level abnormal (F side / BLUE/EVEN pixel)
  • Page 135 SP4-XXX (Scanner) [0 to 65535 / 0 / 1/step] Bit7: Unused Bit6: Unused Bit5: Black level abnormal (F side/RED/EVEN Pixel) Bit4: Black level abnormal (F side /RED/ODD Pixel) Black level:F Bit3: Black level abnormal (F side / GREEN/EVEN Pixel) Bit2: Black level abnormal (F side / GREEN/ODD Pixel) Bit1: Black level abnormal (F side / BLUE/EVEN Pixel)
  • Page 136 2. Main SP Tables-4 [0 to 65535 / 0 / 1/step] Bit7: Unused Bit6: Unused Bit5: SSCG correction error (Fside/RED/EVEN Pixel) Bit4: SSCG correction error (Fside/RED/ODD Pixel) SSCG Correction:F Bit3: SSCG correction error (Fside/ GREEN/EVEN Pixel) Bit2: SSCG correction error (Fside/ GREEN/ODD Pixel) Bit1: SSCG correction error (Fside/ BLUE/EVEN Pixel)
  • Page 137 SP4-XXX (Scanner) [0 to 65535 / 0 / 1/step] Bit15: Unused Bit14: Unused Bit13: White level abnormal (L side/RED/EVEN Pixel) Bit12: White level abnormal (L side/RED/ODD Pixel) Bit11: White level abnormal (L side/ GREEN/EVEN Pixel) Bit10: White level abnormal (L side/ GREEN/ODD Pixel) Bit9: White level abnormal (L side/ BLUE/EVEN Pixel)
  • Page 138 2. Main SP Tables-4 [0 to 65535 / 0 / 1/step] Bit7: Unused Bit6: Unused Bit5: Black level abnormal (L Side/RED/EVEN Pixel) Bit4: Black level abnormal (L Side/RED/ODD Pixel) Black level:L Bit3: Black level abnormal (L Side/ GREEN/EVEN Pixel) Bit2: Black level abnormal (L Side/ GREEN/ODD Pixel) Bit1: Black level abnormal (L Side/ BLUE/EVEN Pixel)
  • Page 139 SP4-XXX (Scanner) [0 to 65535 / 0 / 1/step] Bit7: Unused Bit6: Unused Bit5: SSCG correction error (L side/RED/EVEN Pixel) Bit4: SSCG correction error (L side/RED/ODD Pixel) SSCG Correction:L Bit3: SSCG correction error (L side/ GREEN/EVEN Pixel) Bit2: SSCG correction error (L side/ GREEN/ODD Pixel) Bit1: SSCG correction error (L side/ BLUE/EVEN Pixel)
  • Page 140 2. Main SP Tables-4 [Scanner Hard Error] 4647 Displays result of SBU connection check. [0 to 65535 / 0 / 1/step] Bit15: Unused Bit14:SBU hardware error (Power ON/un-reset error) Bit13:SBU hardware error (Serial communication error: F side) Bit12:SBU hardware error (Reset error: F side) Bit11: Unused Bit10: Unused...
  • Page 141 SP4-XXX (Scanner) Latest:F:RE [0 to 127 / 0 / 1digit/step] Displays Black level analog adjustment value (F side/RED/EVEN Pixel). Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT). Black level is checked when Scanner turns on, then adjustment value is given. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
  • Page 142 2. Main SP Tables-4 Latest:F:GO [0 to 127 / 0 / 1digit/step] Displays Black level analog adjustment value (F side/GREEN/ODD Pixel). Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT). Black level is checked when Scanner turns on, then Adjustment value is given. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
  • Page 143 SP4-XXX (Scanner) Latest:L:BE [0 to 127 / 0 / 1digit/step] Displays Black level analog adjustment value (L side/BLUE/EVEN Pixel). Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT). Black level is checked when Scanner turns on, then Adjustment value is given. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
  • Page 144 2. Main SP Tables-4 Latest:L:RO [0 to 16383 / 0 / 1digit/step] Displays Black level digital adjustment value (L side/RED/ODD Pixel). Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT). Black level is checked when Scanner turns on, then Adjustment value is given. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
  • Page 145 SP4-XXX (Scanner) Latest:F:BE [0 to 16383 / 0 / 1digit/step] Displays Black level digital adjustment value (F side/BLUE/EVEN Pixel). Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT). Black level is checked when Scanner turns on, then Adjustment value is given. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
  • Page 146 2. Main SP Tables-4 Latest:L:R *ENG [0 to 14 / 0 / 1digit/step] Displays Analog gain adjustment value (L side/RED Pixel). White level adjustment will be done to keep hold of image signal’s dynamic range when Scanner turns on. Gain adjustment will be done hardwarelly by SBUs ASIC (SCAT) and be given, cause to the fact that White level adjustment will amplify or attenuated image signal.
  • Page 147 SP4-XXX (Scanner) Latest:L:B *ENG [0 to 14 / 0 / 1digit/step] Displays Analog gain adjustment value (L side/BLUE Pixel). White level adjustment will be done to keep hold of image signal’s dynamic range when Scanner turns on. Gain adjustment will be done hardwarelly by SBUs ASIC (SCAT) and be given, cause to the fact that White level adjustment will amplify or attenuated image signal.
  • Page 148 2. Main SP Tables-4 Latest:L:RO *ENG [0 to 1023 / 0 / 1digit/step] Displays Digital gain adjustment value (L side/RED/ODD Pixel). White level adjustment will be done to keep hold of image signal’s dynamic range when Scanner turns on. Gain adjustment will be done hardwarelly by SBUs ASIC (SCAT) and be given, cause to the fact that White level adjustment will Amplify or Attenuated image signal.
  • Page 149 SP4-XXX (Scanner) Latest:L:GO *ENG [0 to 1023 / 0 / 1digit/step] Displays Digital gain adjustment value (L side/GREEN/ODD Pixel). White level adjustment will be done to keep hold of image signal’s dynamic range when Scanner turns on. Gain adjustment will be done hardwarelly by SBUs ASIC (SCAT) and be given, cause to the fact that White level adjustment will Amplify or Attenuated image signal.
  • Page 150 2. Main SP Tables-4 Latest:L:BO *ENG [0 to 1023 / 0 / 1digit/step] Displays Digital gain adjustment value (L side/BLUE/ODD Pixel). White level adjustment will be done to keep hold of image signal’s dynamic range when Scanner turns on. Gain adjustment will be done hardwarelly by SBUs ASIC (SCAT) and be given, cause to the fact that White level adjustment will Amplify or Attenuated image signal.
  • Page 151 SP4-XXX (Scanner) Factory Set:F:GE *ENG [0 to 127 / 0 / 1digit/step] Display/Saves Factory Black level analog adjusting value (F side/GREEN/EVEN Pixel) Factory Black level analog adjusting value from Main unit warranty process is saved. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC). Factory Set:F:GO *ENG [0 to 127 / 0 / 1digit/step]...
  • Page 152 2. Main SP Tables-4 Factory Set:L:BE *ENG [0 to 127 / 0 / 1digit/step] Display/Saves Factory Black level analog adjusting value (L side/BLUE/EVEN Pixel) Factory Black level analog adjusting value from Main unit warranty process is saved. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC). Factory Set:L:BO *ENG [0 to 127 / 0 / 1digit/step]...
  • Page 153 SP4-XXX (Scanner) Factory :F:GE *ENG [0 to 16383 / 0 / 1digit/step] Display/Saves Factory Black level digital adjusting value (F side/GREEN/EVEN Pixel) Factory Black level digital adjusting value from Main unit warranty process is saved. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC). Factory :F:GO *ENG [0 to 16383 / 0 / 1digit/step]...
  • Page 154 2. Main SP Tables-4 Factory :L:BE *ENG [0 to 16383 / 0 / 1digit/step] Display/Saves Factory Black level digital adjusting value (L side/BLUE/EVEN Pixel) Factory Black level digital adjusting value from Main unit warranty process is saved. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC). Factory :L:BO *ENG [0 to 16383 / 0 / 1digit/step]...
  • Page 155 SP4-XXX (Scanner) Factory :F:B *ENG [0 to 14 / 0 / 1digit/step] Display/Saves Factory Analog gain adjusting value (F side/BLUE Pixel) Factory Analog gain adjusting value from Main unit warranty process is saved. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC). Factory :L:B *ENG [0 to 14 / 0 / 1digit/step]...
  • Page 156 2. Main SP Tables-4 Factory :F:GE *ENG [0 to 1023 / 0 / 1digit/step] Display/Saves Factory Digital gain adjusting value (F side/GREEN/EVEN Pixel) Factory Digital gain adjusting value from Main unit warranty process is saved. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC). Factory :F:GO *ENG [0 to 1023 / 0 / 1digit/step]...
  • Page 157 SP4-XXX (Scanner) Factory :L:BE *ENG [0 to 1023 / 0 / 1digit/step] Display/Saves Factory Digital gain adjusting value (L side/BLUE/EVEN Pixel) Factory Digital gain adjusting value from Main unit warranty process is saved. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC). Factory :L:BO *ENG [0 to 1023 / 0 / 1digit/step]...
  • Page 158 2. Main SP Tables-4 F:RO [0 to 1023 / 0 / 1digit/step] Displays White level peek scanning value (F side/RED/ODD Pixel). Adjusts White level by scanning White Basis Board to keep hold of Scanner’s image signal’s dynamic range when Scanner turns on. Scan level for White Basis Board when adjusting white level will be given.
  • Page 159 SP4-XXX (Scanner) F:GE [0 to 1023 / 0 / 1digit/step] Displays White level peek scanning value (F side/GREEN/EVEN Pixel). Adjusts White level by scanning White Basis Board to keep hold of Scanner’s image signal’s dynamic range when Scanner turns on. Scan level for White Basis Board when adjusting white level will be given.
  • Page 160 2. Main SP Tables-4 L:GO [0 to 1023 / 0 / 1digit/step] Displays White level peek scanning value (L side/GREEN/ODD Pixel). Adjusts White level by scanning White Basis Board to keep hold of Scanner’s image signal’s dynamic range when Scanner turns on. Scan level for White Basis Board when adjusting white level will be given.
  • Page 161 SP4-XXX (Scanner) L:BE [0 to 1023 / 0 / 1digit/step] Displays White level peek scanning value (L side/BLUE/EVEN Pixel). Adjusts White level by scanning White Basis Board to keep hold of Scanner’s image signal’s dynamic range when Scanner turns on. Scan level for White Basis Board when adjusting white level will be given.
  • Page 162 2. Main SP Tables-4 F:RO [0 to 1023 / 0 / 1digit/step] Displays Black level peek scanning value (F side/RED/ODD Pixel). Image signal’s offset level will be checked and given when Scanner turns on and the Black level is checked. Confirming if SBU‘s (SCAT) offset adjusting function is running normal.
  • Page 163 SP4-XXX (Scanner) F:GE [0 to 1023 / 0 / 1digit/step] Displays Black level peek scanning value (F side/GREEN/EVEN Pixel). Image signal’s offset level will be checked and given when Scanner turns on and the Black level is checked. Confirming if SBU‘s (SCAT) offset adjusting function is running normal. When Black level peak scanning value is abnormal, SC141-00 is given.
  • Page 164 2. Main SP Tables-4 4695 [Black Level Data] F:BE [0 to 1023 / 0 / 1digit/step] Displays Black level peek scanning value (F side/BLUE/EVEN Pixel). Image signal’s offset level will be checked and given when Scanner turns on and the Black level is checked.
  • Page 165 SP4-XXX (Scanner) L:BO [0 to 1023 / 0 / 1digit/step] Displays Black level peek scanning value (L side/BLUE/ODD Pixel). Image signal’s offset level will be checked and given when Scanner turns on and the Black level is checked. Confirming if SBU‘s (SCAT) offset adjusting function is running normal. When Black level peak scanning value is abnormal, SC141-00 is given.
  • Page 166 2. Main SP Tables-4 [0 to 8191 / 4095 / 1digit/step] Display/Saves gray balance adjusting value (RED) of CIS. Value adjusted during the DF warranty process is saved. 4713 [CIS GB Adj Value: G] [0 to 8191 / 4095 / 1digit/step] Display/Saves gray balance adjusting value (GREEN) of CIS.
  • Page 167 SP4-XXX (Scanner) [0 to 65535 / 0 / 1/step] b15: Unused b14: Unused b13: Unused b12: Unused b11:Red White level error flag b10:Green White level error flag b9:Blue White level error flag b8: Unused b7: Unused b6: Unused b5:Red Black level error flag b4:Green Black level error flag b3:Blue Black level error flag b2:Red White level front end-back...
  • Page 168 2. Main SP Tables-4 [0 to 7 / 0 / 1/step] b 2:Red Gray balance adjusting error flag (GB_ERR_R) CIS GB Adj Error Flag b 1:Green Gray balance adjusting error flag (GB_ERR_G) b 0:Blue gray balance adjusting error flag (GB_ERR_B) Display Gray balance adjusting error flag for CIS.
  • Page 169 SP4-XXX (Scanner) Leading Edge [0 to 255 / 0 / 1digit/step] Displays main scan white level average value (R leading edge) for CIS. Checks errors for light source by scanning White basis roller witch is set to match CIS when DF powers ON.
  • Page 170 2. Main SP Tables-4 Leading Edge [0 to 255 / 0 / 1digit/step] Displays main scan white level average value (G leading edge) for CIS. Checks errors for light source by scanning White basis roller witch is set to match CIS when DF powers ON.
  • Page 171 SP4-XXX (Scanner) Leading Edge [0 to 255 / 0 / 1digit/step] Displays main scan white level average value (B leading edge) for CIS. Checks errors for light source by scanning White basis roller witch is set to match CIS when DF powers ON.
  • Page 172 2. Main SP Tables-4 Factory Setting *ENG [0 to 255 / 0 / 1digit/step] Display/Saves Factory White level; peak data (GREEN) for CIS. Factory white level; peak data from Main unit warranty process is saved. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC) 4789 CIS White Level Peak Data: B Factory Setting...
  • Page 173 SP4-XXX (Scanner) [0 to 255 / 0 / 1digit/step] Displays White level; peak data (BLUE) for CIS. Checks White level by scanning White basis roller witch is set to mach CIS DF powers ON. Reading level of White basis roller from white level check is given. When white level peak scanning value is abnormal, SC188-00 (White level error) is given.
  • Page 174 2. Main SP Tables-4 014 Chip14 [0 to 255 / 0 / 1digit/step] 015 Chip15 [0 to 255 / 0 / 1digit/step] 016 Chip16 [0 to 255 / 0 / 1digit/step] 017 Chip17 [0 to 255 / 0 / 1digit/step] 018 Chip18 [0 to 255 / 0 / 1digit/step] 019 Chip19...
  • Page 175 SP4-XXX (Scanner) 009 Chip9 [0 to 255 / 0 / 1digit/step] 010 Chip10 [0 to 255 / 0 / 1digit/step] 011 Chip11 [0 to 255 / 0 / 1digit/step] 012 Chip12 [0 to 255 / 0 / 1digit/step] 013 Chip13 [0 to 255 / 0 / 1digit/step] 014 Chip14 [0 to 255 / 0 / 1digit/step]...
  • Page 176 2. Main SP Tables-4 004 Chip4 [0 to 255 / 0 / 1digit/step] 005 Chip5 [0 to 255 / 0 / 1digit/step] 006 Chip6 [0 to 255 / 0 / 1digit/step] 007 Chip7 [0 to 255 / 0 / 1digit/step] 008 Chip8 [0 to 255 / 0 / 1digit/step] 009 Chip9...
  • Page 177 SP4-XXX (Scanner) [0 to 3 / 0 / 1/step] 0: No color correction for low chrome area(Default) Front Side *ENG 1: Correct low chroma area(weak) 2: Correct low chroma area(medium) 3: Correct low chroma area(strong) Corrects color for low chroma area of front side. With 1 path duplex model, color might change between front/Rear sides due to scanning format difference.
  • Page 178 2. Main SP Tables-4 4798 [CIS LED Duty] CIS LED Duty *ENG [0 to 65535 / 0 / 1/step] Display/Saves LED lighting duty for CIS. Value set when shipping test for CIS is saved. Normally won’t change this setting. 4799 [CIS TEST Pattern] [0 to 5 / 0 / 1/step] 0: Scanned Image...
  • Page 179 SP4-XXX (Scanner) [0 or 1 / 1 / 1/step] *ENG 0:OFF 1:ON(default) Sets ON/OFF variable correction for Originals scanning level when continuously scanning multiple originals using ADF. For increasing productivity of ADF, creating correction data is done at a certain (3min) interval.
  • Page 180 2. Main SP Tables-4 Latest *ENG [0 to 8191 / 0 / 1digit/step] Displays adjustment value of LED lighting duty (PWM) for LED light quantity adjustment. Reduces light quantity when CCD’s output is overflowed from the amount of light, by adjusting LED light source lighting duty when scanner powers ON.
  • Page 181 SP4-XXX (Scanner) Latest:F:GE *ENG [0 to 1023 / 0 / 1digit/step] Displays scanning values of White level peak (F side/GREEN/EVEN Pixel) for LED light quantity adjustment. Scanning levels of White basis board will be displayed when scanner powers on and LED light source lighting duty (PWM) is adjusted.
  • Page 182 2. Main SP Tables-4 Latest:L:RE *ENG [0 to 1023 / 0 / 1digit/step] Displays scanning values of White level peak (L side/RED/EVEN Pixel) for LED light quantity adjustment. Scanning levels of White basis board will be displayed when scanner powers on and LED light source lighting duty (PWM) is adjusted.
  • Page 183 SP4-XXX (Scanner) Latest:L:BE *ENG [0 to 1023 / 0 / 1digit/step] Displays scanning values of White level peak (L side/BLUE/EVEN Pixel) for LED light quantity adjustment. Scanning levels of White basis board will be displayed when scanner powers on and LED light source lighting duty (PWM) is adjusted.
  • Page 184 2. Main SP Tables-4 Factory Setting:F:GO *ENG [0 to 1023 / 0 / 1digit/step] Display/Saves White level peak scanning value (F side/GREEN/ODD) for factory light quantity adjustment of LED. Factory scanning value for white level peak from main unit warranty process. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
  • Page 185 SP4-XXX (Scanner) Factory Setting:L:GO *ENG [0 to 1023 / 0 / 1digit/step] Display/Saves White level peak scanning value (L side/GREEN/ODD) for factory light quantity adjustment of LED. Factory scanning value for white level peak from main unit warranty process. Use for design evaluation, analyzing cause of malfunction (abnormal images, SC). Factory Setting:L:BE *ENG [0 to 1023 / 0 / 1digit/step]...
  • Page 186 2. Main SP Tables-4 G_DATA2 *ENG [0 to 255 / 0 / 1/step] Displays (0 to 255) scan value (G component) of scanner for AAC pattern (Magenta max. density area) B_DATA3 *ENG [0 to 255 / 0 / 1/step] Displays (0 to 255) scan value (B component) of scanner for AAC pattern (Yellow max. density area) 4905 [Select Gradation Level]...
  • Page 187 SP4-XXX (Scanner) Coverage Ctrl OFF *ENG [0 to 400 / 400 / 1/step] [Coverage Ctrl: Photo] 4931 001 Copy: Full Color 1 *ENG [0 to 400 / 240 / 1/step] 002 Copy: Full Color 2 *ENG [0 to 400 / 260 / 1/step] 003 Copy: Single Color *ENG [0 to 400 / 100 / 1/step]...
  • Page 188 2. Main SP Tables-4 Set Std Chart [0 or 1 / 0 / 1/step] Re-write scan settings (front side current value) of normal chart. Chromaticity Rank *ENG [0 to 255 / 0 / 1/step] Correct dispersion of scanner reading value among same models, based on the Color degree rank setting value of Scanner (front side).
  • Page 189 SP4-XXX (Scanner) 4994 [Adj Txt/Photo Recog Level] High Compression PDF *ENG [0 to 2 / 1 / 1/step] Adjusts the guide for recognize images text area and image area. Settings are 0: textish, 1: basic 2:imageish 4996 [White Paper Detection Level] *ENG [0 to 6 / 3 / 1/step] Sets blank paper detect level.
  • Page 190 2. Main SP Tables-4...
  • Page 191: Main Sp Tables-5

    3. Main SP Tables-5 SP5-009 to 721 (Mode) [Add Display Language] Adds language available in user choice. (Only the languages registered in the machine) Refer to the displayed language list to set in the way showed below. List Number Assigned Bit Switch No.1 to 8 BIT1 to 8 (SP5009-201) No.9 to 16BIT1 to 8 (SP5009-202) 5009...
  • Page 192 3. Main SP Tables-5 [0 or 1 / 1 / 1/step] 001 Status Lamp Mode *CTL 0: Off 1: On [Accounting counter] RTB 178 Corrected Selects the counting method. 5045 • The counting method can be changed only once, regardless of whether the counter value is negative or positive.
  • Page 193 SP5-009 to 721 (Mode) [Toner Remaining Icon Display Change] 5061 Display or does not display the remaining toner display icon on the LCD. 001 - *CTL [0 or 1 / 0 / 1/step] [Part Replacement Alart Display] 5062 [0 or 1 / 0 / 1/step] 001 #PCDU:K *CTL 0: No display...
  • Page 194 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 012 Apply Blade:K *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 013 Joint:Cleaning Unit:K *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 014 Gear:Cleaning:K *CTL 0: No display...
  • Page 195 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 027 Developer:C *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 028 Developer Filter:C *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 031 #Cleaning Unit:C *CTL 0: No display...
  • Page 196 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 041 Charge Roller:C *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 042 Charge Roller Cleaner:C *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 043 Gear:Charge Roller:C *CTL 0: No display...
  • Page 197 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 056 Brush Roller:M *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 057 Coating Bar:M *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 058 Apply Blade:M *CTL 0: No display...
  • Page 198 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 070 #PCDU:Y *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 072 #Development Unit:Y *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 073 Developer:Y *CTL 0: No display...
  • Page 199 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 083 Gear:Cleaning:Y *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 086 #Charge Roller Unit:Y *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 087 Charge Roller:Y *CTL 0: No display...
  • Page 200 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 097 Transfer Roller:ITB:M *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 098 Transfer Roller:ITB:Y *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 099 Paper Transfer:Backup Roller:ITB *CTL 0: No display...
  • Page 201 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 111 PTR (Paper Transfer Unit) *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 114 #Fusing Unit Assy *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 115 #Fusing Unit *CTL 0: No display...
  • Page 202 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 126 Web Cleaning Roller *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 127 Web Brake Pad *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 130 #Filter:Main *CTL 0: No display...
  • Page 203 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 146 Pick-up Roller:Tray1 *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 147 Feed Roller:Tray1 *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 148 Separation Roller:Tray1 *CTL 0: No display...
  • Page 204 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 160 Separation Roller:Tray3 *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 163 #Tray4 Rollers *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 164 Pick-up Roller:Tray4 *CTL 0: No display...
  • Page 205 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 176 Pick-up Roller:A3_DLT LCT *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 177 Feed Roller:A3_DLT LCT *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 178 Separation Roller:A3_DLT LCT *CTL 0: No display...
  • Page 206 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 190 Separation Roller:Inserter Tray1 *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 193 #Inseter Tray2 Rollers *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 194 Pick-up Roller:Inserter Tray2 *CTL 0: No display...
  • Page 207 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 206 Feed Belt:ADF *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 207 Separation Roller:ADF *CTL 0: No display 1: Display [0 or 1 / 0 / 1/step] 208 Pick-up Roller:ADF *CTL 0: No display...
  • Page 208 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 008 #Cleaning Unit:K *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 009 Cleaning Blade:K *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 010 Brush Roller:K *CTL 0: Service...
  • Page 209 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 020 Gear:Charge Roller:K *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 021 #Photo Conductor:K *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 024 #PCDU:C *CTL 0: Service...
  • Page 210 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 035 Apply Blade:C *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 036 Joint:Cleaning Unit:C *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 037 Gear:Cleaning:C *CTL 0: Service...
  • Page 211 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 050 Developer:M *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 051 Developer Filter:M *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 054 #Cleaning Unit:M *CTL 0: Service...
  • Page 212 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 064 Charge Roller:M *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 065 Charge Roller Cleaner:M *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 066 Gear:Charge Roller:M *CTL 0: Service...
  • Page 213 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 079 Brush Roller:Y *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 080 Coating Bar:Y *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 081 Apply Blade:Y *CTL 0: Service...
  • Page 214 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 093 #ITB Unit *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 094 ITB (Intermedediate Transfer Belt) *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 095 Transfer Roller:ITB:K *CTL 0: Service...
  • Page 215 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 105 ITB Lubricant bar *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 106 ITB Lubricant blade *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 109 #PTR Unit *CTL 0: Service...
  • Page 216 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 119 Shaft Bearing:Press Roller *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 120 Refresh Roller *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 124 #Fusing Cleaning Unit *CTL 0: Service...
  • Page 217 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 134 Deodorant Filter:Large *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 135 Deodorant Filter:Small *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 142 Waste Toner Bottle *CTL 0: Service...
  • Page 218 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 154 Separation Roller:Tray2 *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 157 #Tray3 Rollers *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 158 Pick-up Roller:Tray3 *CTL 0: Service...
  • Page 219 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 170 Pick-up Roller:By-pass *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 171 Feed Roller:By-pass *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 172 Separation Roller:By-pass *CTL 0: Service...
  • Page 220 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 184 Separation Roller:A4_LT LCT *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 187 #Inseter Tray1 Rollers *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 188 Pick-up Roller:Inserter Tray1 *CTL 0: Service...
  • Page 221 SP5-009 to 721 (Mode) [0 or 1 / 0 / 1/step] 200 Feed Belt:Interposer *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 201 Separation Roller:Interposer *CTL 0: Service 1: User [0 or 1 / 0 / 1/step] 202 Pick-up Roller:Interposer *CTL 0: Service...
  • Page 222 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 001 Waste Tonner Bottle *CTL 0:No Display 1:Display [Home Key Customization] 5074 Sets applications that appear on the operation panel when “home key” is pressed. [FFh / 00000000 / 1hex/step] 002 Login Setting *CTL 0:On, 1:Off...
  • Page 223 SP5-009 to 721 (Mode) [LED Light Switch Setting] 5083 Turns LED lighting ON and OFF at Toner Near End. [0 or 1 / 0 / 1/step] 001 Toner Near End *CTL 0: OFF 1: ON [DoubleCount] A3/DLT Double Count (SSP) RTB 178 Corrected Specifies whether the counter is doubled for A3/DLT.
  • Page 224 3. Main SP Tables-5 [0 to 9 / 0 / 1/step] 0: None 1: Key card (RK 3, 4) 2: Key card (down) 3: Prepaid card Default Optional Counter Type *CTL 4: Coin rack 5: MF key card 6: Coin Rack(Recommend) 8: Key counter + Vendor 9: Bar-code Printer This program specifies the counter type.
  • Page 225 SP5-009 to 721 (Mode) [Mode Clear Opt. Counter Removal] 5120 This program updates the information on the optional counter. When you install or remove an optional counter, check the settings. [0 to 2 / 0 / 1/step] 0: Yes (removed) 001 0: Yes 1: Standby 2: No *CTL 1: Standby (installed but not used)
  • Page 226 3. Main SP Tables-5 001 - *CTL [- / 0 / -] [Paper Size Type Selection] 5131 The program selects a paper size system from the following alternatives: the AB system (0), the LT system (1), and the AF system (2). [0 to 2 / 2 / 1/step] 0: DOM(Japan) 001 -...
  • Page 227 SP5-009 to 721 (Mode) 004 DLTT [2.0 to 25.0 / 2.0 / 0.1mm/step] 005 LGT [2.0 to 25.0 / 2.0 / 0.1mm/step] 006 LTT [2.0 to 25.0 / 2.0 / 0.1mm/step] 007 12x18 [2.0 to 25.0 / 2.0 / 0.1mm/step] 008 Other [2.0 to 25.0 / 2.0 / 0.1mm/step] [Auto Delete Time]...
  • Page 228 3. Main SP Tables-5 [TCRU: Set Machine] • TCRU: Set Machine 5185 • TCRU becomes intended when “On” is selected and Replacement Banner Display etc. switch. [0 or 1 / 0 / 1/step] 001 - *ENG 0:OFF 1:ON [RK4] Enables or disables the prevention for RK4 (accounting device) disconnection. 5186 If the RK4 is disconnected for 10 seconds when this SP is set to "1 (Enable)", the machine automatically jams a sheet of paper.
  • Page 229 SP5-009 to 721 (Mode) [0 to 10 / 0 / 1/step] 0: External Controller is not installed 1: EFI, 2: Ratio, 3: Egret 001 - 4: GJ, 5:Creo, 6: QX-100 7: Kurofune 8~10: Reserved [Limitless SW] 5195 Switches productivity precede limit less feed and use paper up limit less feed. [0 or 1 / 0 / 1/step] 001 - *CTL...
  • Page 230 3. Main SP Tables-5 [Page Numbering] This program adjusts the position of the second side page numbers. 5212 • "- value" moves the page number positions to the left edge. • "+ value" moves the page number positions to the right edge. 003 Duplex Printout Right/Left Position *CTL [-10 to 10 / 0 / 1mm/step]...
  • Page 231 SP5-009 to 721 (Mode) [0 to 1 / 1 / 1/step] 0: Disabled 1: Enabled Setting *CTL (Default) 1: NA and EUR 0: ASIA and others Enables or disables the summer time mode. • Make sure that both SP5-307-3 and -4 are correctly set. Otherwise, this SP is not activated even if this SP is set to "1".
  • Page 232 3. Main SP Tables-5 [0 to 0xffffffff / 10500100h / 1hex/ Rule Set(End) *CTL step] Specifies the end setting for the summer time mode. There are 8 digits in this SP. 1st and 2nd digits: The month. [1 to 12] 3rd digit: The week of the month.
  • Page 233 SP5-009 to 721 (Mode) 211 SDK2 Certification Method *CTL [0 to 0xff / 0 / 1 / step ] 220 SDK3 UniqueID *CTL [0 to 0xffffffff / 0 / 1/step] 221 SDK3 Certification Method *CTL [0 to 0xff / 0 / 1/step] [ - / 0 / - ] 0-1: SDK authentication available 0-0: Disable all functions...
  • Page 234 3. Main SP Tables-5 101 SDKJ1 Limit Setting *CTL [ / 0x00 / 0x01/step] bit0: SDKJ Authentication 102 SDKJ2 Limit Setting *CTL -0: Panel Type 103 SDKJ3 Limit Setting *CTL -1: Remote Type 104 SDKJ4 Limit Setting *CTL bit1: Using user code setup -0: OFF, 1: ON 105 SDKJ5 Limit Setting *CTL...
  • Page 235 SP5-009 to 721 (Mode) 111 SDKJ11 Limit Setting *CTL [ / 0x00 / 0x01/step] bit0: SDKJ Authentication 112 SDKJ12 Limit Setting *CTL -0: Panel Type 113 SDKJ13 Limit Setting *CTL -1: Remote Type 114 SDKJ14 Limit Setting *CTL bit1: Using user code setup -0: OFF, 1: ON 115 SDKJ15 Limit Setting *CTL...
  • Page 236 3. Main SP Tables-5 121 SDKJ21 Limit Setting *CTL [ / 0x00 / 0x01/step] bit0: SDKJ Authentication 122 SDKJ22 Limit Setting *CTL -0: Panel Type 123 SDKJ23 Limit Setting *CTL -1: Remote Type 124 SDKJ24 Limit Setting *CTL bit1: Using user code setup -0: OFF, 1: ON 125 SDKJ25 Limit Setting *CTL...
  • Page 237 SP5-009 to 721 (Mode) 141 SDKJ1 ProductID *CTL [0 to 0xffffffff / 0 / 1/step] 142 SDKJ2 ProductID *CTL 143 SDKJ3 ProductID *CTL 144 SDKJ4 ProductID *CTL 145 SDKJ5 ProductID *CTL 146 SDKJ6 ProductID *CTL 147 SDKJ7 ProductID *CTL 148 SDKJ8 ProductID *CTL 149 SDKJ9 ProductID *CTL...
  • Page 238 3. Main SP Tables-5 155 SDKJ15 ProductID *CTL [0 to 0xffffffff / 0 / 1/step] 156 SDKJ16 ProductID *CTL 157 SDKJ17 ProductID *CTL 158 SDKJ18 ProductID *CTL 159 SDKJ19 ProductID *CTL 160 SDKJ20 ProductID *CTL 161 SDKJ21 ProductID *CTL 162 SDKJ22 ProductID *CTL 163 SDKJ23 ProductID *CTL...
  • Page 239 SP5-009 to 721 (Mode) [0 or 1 / 1 / -] Password Null Not Permit *CTL 0: Password NULL permitted. 1: Password NULL not permitted. This SP is referenced only when SP5411-4 is set to "1" (On). [ - / 0x00 / 0x01/step] Detail Option *CTL Bit0...
  • Page 240 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 0: OFF (lockout not cancelled) Cancellation On/Off *CTL 1: ON (system waits, cancels lockout if correct user ID and password are entered) Determines whether the system waits the prescribed time for input of a correct user ID and password after an account lockout has occurred.
  • Page 241 SP5-009 to 721 (Mode) Access Password Max Num *CTL [50 to 200 / 200 / 1/step] Limits the number of passwords used by the access exclusion and password attack detection functions. Monitor Interval *CTL [1 to 10 / 3 / 1 sec/step] Sets the processing time interval for referencing user ID and password information.
  • Page 242 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] DocumentServer *CTL 0: Authentication ON 1: Authentication OFF Determines whether certification is required before a user can use the document server. [0 or 1 / 0 / 1/step] *CTL 0: Authentication ON 1: Authentication OFF Determines whether certification is required before a user can use the fax application.
  • Page 243 SP5-009 to 721 (Mode) Message Change On/Off *CTL [0 or 1 / 0 / 1/step] Turns on or off the displayed message change for the authentication. [- / - / -] Message Text Download [Execute] Executes the message download for the authentication. Message Text ID [characters(max.16Byte) / \0 /-] Inputs message text for the authentication.
  • Page 244 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] System Log Disp *CTL 0: Display OFF 1: Display ON Determines whether an error code appears in the system log after a user authentication failure occurs. [0 or 1 / 1 / 1/step] Panel Disp *CTL 0: Display OFF...
  • Page 245 SP5-009 to 721 (Mode) [0 to 3 / 3 / 1/step] 0: Zero (Off) *CTL 1: Low (2.5K jams) 2: Medium (3K jams) 3: High (6K jams) Sets the alarm to sound for the specified jam level (document miss feeds are not included). [Error Alarm] Sets the error alarm level.
  • Page 246 3. Main SP Tables-5 [0 to 2 / 1 / 1/step] 0: OFF 006 Toner Collection Bottle Alarm *CTL 1: Supply call enabled 2: CC call enabled Changes the timing of the "Toner Supply Call" via the @Remote, when the following conditions occur. 080 Toner Call Timing *CTL [0 or 1 / 0 / 1/step]...
  • Page 247 SP5-009 to 721 (Mode) [0 or 1 / 1 / 1/step] Continuous Door Open *CTL 0: Disable, 1: Enable Enables/disables initiating a call when the front door remains open. Jam Detection: Time Length *CTL [3 to 30 / 10 / 1min./step] Sets the time a jam must remain before it becomes an “unattended paper jam”.
  • Page 248 3. Main SP Tables-5 001 SC Call *CTL 002 Service Parts Near End Call *CTL 003 Service Parts End Call *CTL 004 User Call *CTL 006 Communication Test Call *CTL [0 or 1 / 1 / 1/step] 007 Machine Information Notice *CTL 0: OFF 1: ON...
  • Page 249 SP5-009 to 721 (Mode) 5517 [Get Machine Information] GeCustomPprInfo:RetryInterval *CTL [10 to 255 / 10 / 1min/step] When ID info collect is interrupt, retries during the time between receving Request for obtaining custom paper info, to value set with this setting. Get SMC Info Retry Internal *CTL [10 to 255 / 10 / 1min/step]...
  • Page 250 3. Main SP Tables-5 [0 to 128 / 100 / 1 /step] *ENG 128: Darkest density Adjusts the output color (Y component) ranging from 0 (%) to 128 (%) when Standard Color (Green) is set in Single Color (No correction). [0 to 128 / 100 / 1 /step] *ENG 128: Darkest density...
  • Page 251 SP5-009 to 721 (Mode) 5711 [Custom Setting Paper: Data Setting] [- / - / -] 001 Standard Paper Data UpLoad *CTL [Execute] [- / - / -] 002 Custom Paper Data UpLoad *CTL [Execute] [- / - / -] 102 Custom Paper Data Download *CTL [Execute] [- / - / -]...
  • Page 252 3. Main SP Tables-5 015 ID15 [0 to 7 / 1 / 1/step] 016 ID16 [0 to 7 / 1 / 1/step] 017 ID17 [0 to 7 / 1 / 1/step] 018 ID18 [0 to 7 / 1 / 1/step] 019 ID19 [0 to 7 / 1 / 1/step] 020 ID20...
  • Page 253 SP5-009 to 721 (Mode) 041 ID41 [0 to 7 / 1 / 1/step] 042 ID42 [0 to 7 / 1 / 1/step] 043 ID43 [0 to 7 / 1 / 1/step] 044 ID44 [0 to 7 / 1 / 1/step] 045 ID45 [0 to 7 / 1 / 1/step] 046 ID46...
  • Page 254 3. Main SP Tables-5 067 ID67 [0 to 7 / 1 / 1/step] 068 ID68 [0 to 7 / 1 / 1/step] 069 ID69 [0 to 7 / 1 / 1/step] 070 ID70 [0 to 7 / 1 / 1/step] 071 ID71 [0 to 7 / 1 / 1/step] 072 ID72...
  • Page 255 SP5-009 to 721 (Mode) 093 ID93 [0 to 7 / 1 / 1/step] 094 ID94 [0 to 7 / 1 / 1/step] 095 ID95 [0 to 7 / 1 / 1/step] 096 ID96 [0 to 7 / 1 / 1/step] 097 ID97 [0 to 7 / 1 / 1/step] 098 ID98...
  • Page 256 3. Main SP Tables-5 017 ID17 [0 to 2 / 1 / 1/step] 018 ID18 [0 to 2 / 1 / 1/step] 019 ID19 [0 to 2 / 1 / 1/step] 020 ID20 [0 to 2 / 1 / 1/step] 021 ID21 [0 to 2 / 1 / 1/step] 022 ID22...
  • Page 257 SP5-009 to 721 (Mode) 043 ID43 [0 to 2 / 1 / 1/step] 044 ID44 [0 to 2 / 1 / 1/step] 045 ID45 [0 to 2 / 1 / 1/step] 046 ID46 [0 to 2 / 1 / 1/step] 047 ID47 [0 to 2 / 1 / 1/step] 048 ID48...
  • Page 258 3. Main SP Tables-5 069 ID69 [0 to 2 / 1 / 1/step] 070 ID70 [0 to 2 / 1 / 1/step] 071 ID71 [0 to 2 / 1 / 1/step] 072 ID72 [0 to 2 / 1 / 1/step] 073 ID73 [0 to 2 / 1 / 1/step] 074 ID74...
  • Page 259 SP5-009 to 721 (Mode) 095 ID95 [0 to 2 / 1 / 1/step] 096 ID96 [0 to 2 / 1 / 1/step] 097 ID97 [0 to 2 / 1 / 1/step] 098 ID98 [0 to 2 / 1 / 1/step] 099 ID99 [0 to 2 / 1 / 1/step] 100 ID100...
  • Page 260 3. Main SP Tables-5 019 ID19 [0 to 0xFFFF / 1 / 1/step] 020 ID20 [0 to 0xFFFF / 1 / 1/step] 021 ID21 [0 to 0xFFFF / 1 / 1/step] 022 ID22 [0 to 0xFFFF / 1 / 1/step] 023 ID23 [0 to 0xFFFF / 1 / 1/step] 024 ID24...
  • Page 261 SP5-009 to 721 (Mode) 045 ID45 [0 to 0xFFFF / 1 / 1/step] 046 ID46 [0 to 0xFFFF / 1 / 1/step] 047 ID47 [0 to 0xFFFF / 1 / 1/step] 048 ID48 [0 to 0xFFFF / 1 / 1/step] 049 ID49 [0 to 0xFFFF / 1 / 1/step] 050 ID50...
  • Page 262 3. Main SP Tables-5 071 ID71 [0 to 0xFFFF / 1 / 1/step] 072 ID72 [0 to 0xFFFF / 1 / 1/step] 073 ID73 [0 to 0xFFFF / 1 / 1/step] 074 ID74 [0 to 0xFFFF / 1 / 1/step] 075 ID75 [0 to 0xFFFF / 1 / 1/step] 076 ID76...
  • Page 263 SP5-009 to 721 (Mode) 097 ID97 [0 to 0xFFFF / 1 / 1/step] 098 ID98 [0 to 0xFFFF / 1 / 1/step] 099 ID99 [0 to 0xFFFF / 1 / 1/step] 100 ID100 [0 to 0xFFFF / 1 / 1/step] 5718 [Custom Paper: Up/Web Info.
  • Page 264 3. Main SP Tables-5 021 ID21 [0 to 0xFFFF / 1 / 1/step] 022 ID22 [0 to 0xFFFF / 1 / 1/step] 023 ID23 [0 to 0xFFFF / 1 / 1/step] 024 ID24 [0 to 0xFFFF / 1 / 1/step] 025 ID25 [0 to 0xFFFF / 1 / 1/step] 026 ID26...
  • Page 265 SP5-009 to 721 (Mode) 047 ID47 [0 to 0xFFFF / 1 / 1/step] 048 ID48 [0 to 0xFFFF / 1 / 1/step] 049 ID49 [0 to 0xFFFF / 1 / 1/step] 050 ID50 [0 to 0xFFFF / 1 / 1/step] 051 ID51 [0 to 0xFFFF / 1 / 1/step] 052 ID52...
  • Page 266 3. Main SP Tables-5 073 ID73 [0 to 0xFFFF / 1 / 1/step] 074 ID74 [0 to 0xFFFF / 1 / 1/step] 075 ID75 [0 to 0xFFFF / 1 / 1/step] 076 ID76 [0 to 0xFFFF / 1 / 1/step] 077 ID77 [0 to 0xFFFF / 1 / 1/step] 078 ID78...
  • Page 267 SP5-009 to 721 (Mode) 099 ID99 [0 to 0xFFFF / 1 / 1/step] 100 ID100 [0 to 0xFFFF / 1 / 1/step] 5719 [Custom Paper: Up/Web Info. 3: Punch] 001 ID1 [0 to 0xFFFF / 1 / 1/step] 002 ID2 [0 to 0xFFFF / 1 / 1/step] 003 ID3 [0 to 0xFFFF / 1 / 1/step]...
  • Page 268 3. Main SP Tables-5 023 ID23 [0 to 0xFFFF / 1 / 1/step] 024 ID24 [0 to 0xFFFF / 1 / 1/step] 025 ID25 [0 to 0xFFFF / 1 / 1/step] 026 ID26 [0 to 0xFFFF / 1 / 1/step] 027 ID27 [0 to 0xFFFF / 1 / 1/step] 028 ID28...
  • Page 269 SP5-009 to 721 (Mode) 049 ID49 [0 to 0xFFFF / 1 / 1/step] 050 ID50 [0 to 0xFFFF / 1 / 1/step] 051 ID51 [0 to 0xFFFF / 1 / 1/step] 052 ID52 [0 to 0xFFFF / 1 / 1/step] 053 ID53 [0 to 0xFFFF / 1 / 1/step] 054 ID54...
  • Page 270 3. Main SP Tables-5 075 ID75 [0 to 0xFFFF / 1 / 1/step] 076 ID76 [0 to 0xFFFF / 1 / 1/step] 077 ID77 [0 to 0xFFFF / 1 / 1/step] 078 ID78 [0 to 0xFFFF / 1 / 1/step] 079 ID79 [0 to 0xFFFF / 1 / 1/step] 080 ID80...
  • Page 271 SP5-009 to 721 (Mode) 5720 [Custom Paper: Up/Web Info. 4: Color] 001 ID1 [0 to 0xFFFF / 1 / 1/step] 002 ID2 [0 to 0xFFFF / 1 / 1/step] 003 ID3 [0 to 0xFFFF / 1 / 1/step] 004 ID4 [0 to 0xFFFF / 1 / 1/step] 005 ID5 [0 to 0xFFFF / 1 / 1/step]...
  • Page 272 3. Main SP Tables-5 026 ID26 [0 to 0xFFFF / 1 / 1/step] 027 ID27 [0 to 0xFFFF / 1 / 1/step] 028 ID28 [0 to 0xFFFF / 1 / 1/step] 029 ID29 [0 to 0xFFFF / 1 / 1/step] 030 ID30 [0 to 0xFFFF / 1 / 1/step] 031 ID31...
  • Page 273 SP5-009 to 721 (Mode) 052 ID52 [0 to 0xFFFF / 1 / 1/step] 053 ID53 [0 to 0xFFFF / 1 / 1/step] 054 ID54 [0 to 0xFFFF / 1 / 1/step] 055 ID55 [0 to 0xFFFF / 1 / 1/step] 056 ID56 [0 to 0xFFFF / 1 / 1/step] 057 ID57...
  • Page 274 3. Main SP Tables-5 078 ID78 [0 to 0xFFFF / 1 / 1/step] 079 ID79 [0 to 0xFFFF / 1 / 1/step] 080 ID80 [0 to 0xFFFF / 1 / 1/step] 081 ID81 [0 to 0xFFFF / 1 / 1/step] 082 ID82 [0 to 0xFFFF / 1 / 1/step] 083 ID83...
  • Page 275 SP5-009 to 721 (Mode) 002 ID2 [0 to 0xFF / 1 / 1/step] 003 ID3 [0 to 0xFF / 1 / 1/step] 004 ID4 [0 to 0xFF / 1 / 1/step] 005 ID5 [0 to 0xFF / 1 / 1/step] 006 ID6 [0 to 0xFF / 1 / 1/step] 007 ID7...
  • Page 276 3. Main SP Tables-5 028 ID28 [0 to 0xFF / 1 / 1/step] 029 ID29 [0 to 0xFF / 1 / 1/step] 030 ID30 [0 to 0xFF / 1 / 1/step] 031 ID31 [0 to 0xFF / 1 / 1/step] 032 ID32 [0 to 0xFF / 1 / 1/step] 033 ID33...
  • Page 277 SP5-009 to 721 (Mode) 054 ID54 [0 to 0xFF / 1 / 1/step] 055 ID55 [0 to 0xFF / 1 / 1/step] 056 ID56 [0 to 0xFF / 1 / 1/step] 057 ID57 [0 to 0xFF / 1 / 1/step] 058 ID58 [0 to 0xFF / 1 / 1/step] 059 ID59...
  • Page 278 3. Main SP Tables-5 080 ID80 [0 to 0xFF / 1 / 1/step] 081 ID81 [0 to 0xFF / 1 / 1/step] 082 ID82 [0 to 0xFF / 1 / 1/step] 083 ID83 [0 to 0xFF / 1 / 1/step] 084 ID84 [0 to 0xFF / 1 / 1/step] 085 ID85...
  • Page 279: Sp5-722 To 998 (Mode)

    SP5-722 to 998 (Mode) SP5-722 to 998 (Mode) 5722 [Custom Paper: Width (M-scan 0.1mm)] 001 ID1 [0 to 0xFFFFFFFF / 1 / 0.1/step] 002 ID2 [0 to 0xFFFFFFFF / 1 / 0.1/step] 003 ID3 [0 to 0xFFFFFFFF / 1 / 0.1/step] 004 ID4 [0 to 0xFFFFFFFF / 1 / 0.1/step] 005 ID5...
  • Page 280 3. Main SP Tables-5 024 ID24 [0 to 0xFFFFFFFF / 1 / 0.1/step] 025 ID25 [0 to 0xFFFFFFFF / 1 / 0.1/step] 026 ID26 [0 to 0xFFFFFFFF / 1 / 0.1/step] 027 ID27 [0 to 0xFFFFFFFF / 1 / 0.1/step] 028 ID28 [0 to 0xFFFFFFFF / 1 / 0.1/step] 029 ID29...
  • Page 281 SP5-722 to 998 (Mode) 050 ID50 [0 to 0xFFFFFFFF / 1 / 0.1/step] 051 ID51 [0 to 0xFFFFFFFF / 1 / 0.1/step] 052 ID52 [0 to 0xFFFFFFFF / 1 / 0.1/step] 053 ID53 [0 to 0xFFFFFFFF / 1 / 0.1/step] 054 ID54 [0 to 0xFFFFFFFF / 1 / 0.1/step] 055 ID55...
  • Page 282 3. Main SP Tables-5 076 ID76 [0 to 0xFFFFFFFF / 1 / 0.1/step] 077 ID77 [0 to 0xFFFFFFFF / 1 / 0.1/step] 078 ID78 [0 to 0xFFFFFFFF / 1 / 0.1/step] 079 ID79 [0 to 0xFFFFFFFF / 1 / 0.1/step] 080 ID80 [0 to 0xFFFFFFFF / 1 / 0.1/step] 081 ID81...
  • Page 283 SP5-722 to 998 (Mode) 5723 [Custom Paper: Width (S-scan 0.1mm)] 001 ID1 [0 to 0xFFFFFFFF / 1 / 0.1/step] 002 ID2 [0 to 0xFFFFFFFF / 1 / 0.1/step] 003 ID3 [0 to 0xFFFFFFFF / 1 / 0.1/step] 004 ID4 [0 to 0xFFFFFFFF / 1 / 0.1/step] 005 ID5 [0 to 0xFFFFFFFF / 1 / 0.1/step] 006 ID6...
  • Page 284 3. Main SP Tables-5 026 ID26 [0 to 0xFFFFFFFF / 1 / 0.1/step] 027 ID27 [0 to 0xFFFFFFFF / 1 / 0.1/step] 028 ID28 [0 to 0xFFFFFFFF / 1 / 0.1/step] 029 ID29 [0 to 0xFFFFFFFF / 1 / 0.1/step] 030 ID30 [0 to 0xFFFFFFFF / 1 / 0.1/step] 031 ID31...
  • Page 285 SP5-722 to 998 (Mode) 052 ID52 [0 to 0xFFFFFFFF / 1 / 0.1/step] 053 ID53 [0 to 0xFFFFFFFF / 1 / 0.1/step] 054 ID54 [0 to 0xFFFFFFFF / 1 / 0.1/step] 055 ID55 [0 to 0xFFFFFFFF / 1 / 0.1/step] 056 ID56 [0 to 0xFFFFFFFF / 1 / 0.1/step] 057 ID57...
  • Page 286 3. Main SP Tables-5 078 ID78 [0 to 0xFFFFFFFF / 1 / 0.1/step] 079 ID79 [0 to 0xFFFFFFFF / 1 / 0.1/step] 080 ID80 [0 to 0xFFFFFFFF / 1 / 0.1/step] 081 ID81 [0 to 0xFFFFFFFF / 1 / 0.1/step] 082 ID82 [0 to 0xFFFFFFFF / 1 / 0.1/step] 083 ID83...
  • Page 287 SP5-722 to 998 (Mode) 002 ID2 [0 to 99 / 1 / 2/step] 003 ID3 [0 to 99 / 1 / 2/step] 004 ID4 [0 to 99 / 1 / 2/step] 005 ID5 [0 to 99 / 1 / 2/step] 006 ID6 [0 to 99 / 1 / 2/step] 007 ID7...
  • Page 288 3. Main SP Tables-5 028 ID28 [0 to 99 / 1 / 2/step] 029 ID29 [0 to 99 / 1 / 2/step] 030 ID30 [0 to 99 / 1 / 2/step] 031 ID31 [0 to 99 / 1 / 2/step] 032 ID32 [0 to 99 / 1 / 2/step] 033 ID33...
  • Page 289 SP5-722 to 998 (Mode) 054 ID54 [0 to 99 / 1 / 2/step] 055 ID55 [0 to 99 / 1 / 2/step] 056 ID56 [0 to 99 / 1 / 2/step] 057 ID57 [0 to 99 / 1 / 2/step] 058 ID58 [0 to 99 / 1 / 2/step] 059 ID59...
  • Page 290 3. Main SP Tables-5 080 ID80 [0 to 99 / 1 / 2/step] 081 ID81 [0 to 99 / 1 / 2/step] 082 ID82 [0 to 99 / 1 / 2/step] 083 ID83 [0 to 99 / 1 / 2/step] 084 ID84 [0 to 99 / 1 / 2/step] 085 ID85...
  • Page 291 SP5-722 to 998 (Mode) 004 ID4 [0 to 99 / 1 / 1/step] 005 ID5 [0 to 99 / 1 / 1/step] 006 ID6 [0 to 99 / 1 / 1/step] 007 ID7 [0 to 99 / 1 / 1/step] 008 ID8 [0 to 99 / 1 / 1/step] 009 ID9...
  • Page 292 3. Main SP Tables-5 030 ID30 [0 to 99 / 1 / 1/step] 031 ID31 [0 to 99 / 1 / 1/step] 032 ID32 [0 to 99 / 1 / 1/step] 033 ID33 [0 to 99 / 1 / 1/step] 034 ID34 [0 to 99 / 1 / 1/step] 035 ID35...
  • Page 293 SP5-722 to 998 (Mode) 056 ID56 [0 to 99 / 1 / 1/step] 057 ID57 [0 to 99 / 1 / 1/step] 058 ID58 [0 to 99 / 1 / 1/step] 059 ID59 [0 to 99 / 1 / 1/step] 060 ID60 [0 to 99 / 1 / 1/step] 061 ID61...
  • Page 294 3. Main SP Tables-5 082 ID82 [0 to 99 / 1 / 1/step] 083 ID83 [0 to 99 / 1 / 1/step] 084 ID84 [0 to 99 / 1 / 1/step] 085 ID85 [0 to 99 / 1 / 1/step] 086 ID86 [0 to 99 / 1 / 1/step] 087 ID87...
  • Page 295 SP5-722 to 998 (Mode) [Counter Effect] 5731 Change MK1 Cnt (Paper- *CTL [0 or 1 / 0 / 1/step] >Combine) [PDF Setting] 5734 001 PDF/A Fixed [0 or 1 / 0 / 1/step] [Node Authentication timuout] 5741 001 - *CTL [Network Security Level] 5743 [- / 0x10 / 1bit/step]...
  • Page 296 3. Main SP Tables-5 212 STR *CTL [0 to 9999 / 0 / 1/step] 213 Main Power Off *CTL [0 to 9999 / 0 / 1/step] 214 Scanning and Printing *CTL [0 to 9999 / 0 / 1/step] 215 Printing *CTL [0 to 9999 / 0 / 1/step] 216 Scanning...
  • Page 297 SP5-722 to 998 (Mode) [Letters(Up to 255) / deviceBrowser / 021 User Agent *CTL -/step] [0 or 1 / 0 / 1/step] 031 Use JavaScript *CTL 0: Disable 1: Enable [0 or 1 / 0 / 1/step] 032 Use Extended JavaScript *CTL 0: Disable 1: Enable...
  • Page 298 3. Main SP Tables-5 [Letters(Up to 255) / file:///sdk/ 081 HomePage *CTL exjs/LAPnet/help.asp / -/step] [0 or 1 / 1 / 1/step] 181 User Permit: HomePage *CTL 0: Allow 1: Not Allow [0 or 1 / 1 / 1/step] 182 User Permit: Bookmark *CTL 0: Allow 1: Not Allow...
  • Page 299 SP5-722 to 998 (Mode) [char. code + 0-255 bytechar. / 213 Browser10 NULL / -] [OpePanel Setting] 5748 This SP setting is required when smart operation panel is installed on MFP. [0x00 to 0xFF / 0 / 0x01/step] • bit0 101 Op Type Action Setting 0: Normal operation panel 1: Smart operation panel...
  • Page 300 3. Main SP Tables-5 [Copy FlairAPIFunction Setting] 5752 CopyFlairAPI Function enable / disable. 001 0x00 - 0xff *CTL * see BitSwitch below: meanings Setting Description Sets whether to start exclusive FlairAPI http server. If it is 0, scanning FlairAPI function and Start of FlairAPI bit 0 simple UI function will be...
  • Page 301 SP5-722 to 998 (Mode) If it is “0”, accessing is limited from the machine only Accessing permission (operating panel and MFP of Simple UI from bit 5 Disabled Enabled browser). If it is “1”, accessing outside of the is allowed from outside of machine Simple UI such as PC, mobile devices, and so on.
  • Page 302 3. Main SP Tables-5 5794 [Browser Debug] 001 Browser Debug [0 to 255 / 0 / 1/step] 5795 [SRM Debug SW] 001 1 [0 to 255 / - / 1/step] 5796 [PLN Debug SW] [ - / - / - ] 001 1 [Execute] [Clear Memory]...
  • Page 303 SP5-722 to 998 (Mode) [ - / - / - ] IMH Memory Clr [Execute] Initializes the image file system. (IMH: Image Memory Handler) [ - / - / - ] [Execute] Initializes the automatic delete time setting for stored documents. (MCS: Memory Control Service) [ - / - / - ] Copier Application...
  • Page 304 3. Main SP Tables-5 [ - / - / - ] Web Service [Execute] Deletes the network file application management files and thumbnails, and initializes the job login ID. [ - / - / - ] [Execute] All setting of Network Setup (User Menu) (NCS: Network Control Service) [ - / - / - ] R-Fax...
  • Page 305 SP5-722 to 998 (Mode) [ - / - / - ] [Execute] Initializes the LCS (Log Count Service) settings. [ - / - / - ] Web Uapli [Execute] Initializes the web user application settings. [ - / - / - ] [Execute] Initializes the ECS settings.
  • Page 306 3. Main SP Tables-5 [OUTPUTCheck] 5805 See page 741 [OUTPUTCheck] 5806 See page 741 [Area Selection] 5807 [- / 1 / 1/step] 1:DOM 2:NA 001 - 3:EU 4:TWN 5:AA 6:CHN [SC Reset] Resets a type A service call condition. 5810 •...
  • Page 307 SP5-722 to 998 (Mode) 5812 [Service Tel. No. Setting] Service *CTL [up to 20 / - / 1/step] Sets the telephone number for a service representative. This number is printed on the Counter List, which can be printed with the user’s “Counter” menu. This can be up to 20 characters (both numbers and alphabetic characters can be input).
  • Page 308 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] Function Flag *CTL 0: Disabled, 1: Enabled Enables or disables the remote service function. [- / - / -] 004 Commnication Test Call [Execute] [- / - / -] 005 Device Information Call [Execute] [0 or 1 / 0 / 1/step]...
  • Page 309 SP5-722 to 998 (Mode) [0 or 1 / 1 / 1/step] RFU Timing *CTL 0: Any status of a target machine 1: Sleep or panel off mode only Selects the timing for the remote firmware updating. [0 or 1 / 0 / 1/step] RCG Error Cause 0: Initial state, normal condition 1: Error...
  • Page 310 3. Main SP Tables-5 Proxy Host *CTL [up to 127 / - / 1/step] This SP sets the address of the proxy server used for communication between the RCG device and the gateway. Use this SP to set up or display the customer proxy server address.
  • Page 311 SP5-722 to 998 (Mode) CERT: Up State *CTL [0 to 255 / 0 / 1/step] Displays the status of the certification update. The certification used by Embedded RC Gate is set correctly. The certification request (setAuthKey) for update has been received from the GW URL and certification is presently being updated.
  • Page 312 3. Main SP Tables-5 CERT: Error *CTL [0 to 255 / 0 / 1/step] Displays a number code that describes the reason for the request for update of the certification. Normal. There is no request for certification update in progress. Request for certification update in progress.
  • Page 313 SP5-722 to 998 (Mode) Firmware Size *CTL [- / - / -] Allows the service technician to confirm the size of the firmware data files during the firmware update execution. CERT:Macro Ver. [8digits / - / 1digit/step] Displays the macro version of the @Remote certification. This SP displays 8-digit characters. CERT:PAC Ver.
  • Page 314 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 095 Server CN Check *CTL 0: Check strictly 1: Check easely 096 GW Host [- / - / -] 097 GW URL Path [- / - / -] [- / - / -] 099 Debug RescueG/WURL Set [Execute] 100 Specific Gateway Host...
  • Page 315 SP5-722 to 998 (Mode) [- / - / -] Line Type Automatic Judgement [Execute] Setting this SP classifies the telephone line where embedded RCG-M is connected as either dial-up (pulse dial) or push (DTMF tone) type, so embedded RCG-M can automatically distinguish the number that connects to the outside line.
  • Page 316 3. Main SP Tables-5 Outside Line Outgoing Number *CTL [4digits / - / 1digit/step] The SP sets the number that switches to PSTN for the outside connection for embedded RCG-M in a system that employs a PBX (internal line). • If the execution of SP5816-151 has succeeded and embedded RCG-M has connected to the external line, this SP display is completely blank.
  • Page 317 SP5-722 to 998 (Mode) Connection Timing Adjustment *CTL [0 to 24 / 1 / 1/step] Incoming When the Call Center calls out to an embedded RCG-M modem, it sends a repeating ID tone (*#1#). This SP sets the time the line remains open to send these ID tones after the number of the embedded RCG-M modem is dialed up and connected.
  • Page 318 3. Main SP Tables-5 [0000000 to 11111111 / 186 RCG-C M DebugBitSW 00000000 / -] [0 to 1 / 0 / 1/step] 187 FAX TX Priority 0: OFF 1: ON [- / - / -] Manual Polling [Execute] Executes the center polling manually. Regist Status [0 to 4 / 0 / 1/step] Displays a number that indicates the status of the @Remote service device.
  • Page 319 SP5-722 to 998 (Mode) Confirm Result [0 to 255 / 0 / 1/step] Displays a number that indicates the result of the inquiry executed with SP5816 203. 0: Succeeded 1: Inquiry number error 3: Proxy error (proxy enabled) 4: Proxy error (proxy disabled) 5: Proxy error (Illegal user name or password) 6: Communication error 8: Other error...
  • Page 320 3. Main SP Tables-5 [-2147483647 to 2147483647 / Error Code - / -/step] Displays a number that describes the error code that was issued when either SP5816-204 or SP5816-207 was executed. Cause Code Meaning -11001 Chat parameter error -11002 Chat execution error Illegal Modem -11003 Unexpected error...
  • Page 321 SP5-722 to 998 (Mode) Attempted dial up overseas without the correct -2385 international prefix for the telephone number. -2387 Not supported at the Service Center -2389 Database out of service -2390 Program out of service -2391 Two registrations for same device Error Caused by -2392 Parameter error...
  • Page 322 3. Main SP Tables-5 RCG Port *CTL [0 to 65535/ 443 / 1/step] Sets the port number of the RCG (Remote Communication Gate) destination for call processing at the remote service center. [0 to 16 characters (half characters) 004 RCG URL Path *CTL Default /RCG/services/ -] [NV-RAM Data Upload]...
  • Page 323 SP5-722 to 998 (Mode) 023 Active IPv4 Gateway Address [00000000h to FFFFFFFFh / 00000000h / -] [0 to 1 / 1 / 1/step] 050 1284 Compatiblity (Centro) *CTL 0: Not Allow 1: Allow [0 to 1 / 1 / 1/step] 052 ECP (Centro) *CTL 0: Not Allow...
  • Page 324 3. Main SP Tables-5 Protocol usage *CTL [0 or 1 / 0x00000000 / 1bit/step] Shows which protocols have been used with the network. 0: Off (Not used the network with the protocol.) 1: On (Used the network with the protocol once or more.) bit0: IPsec, bit1: IPv6, bit2: IEEE 802.
  • Page 325 SP5-722 to 998 (Mode) SettingActive IPv6 Stateless [00000000000000000000000000000000 Address 1 0000h to FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF80h / SettingActive IPv6 Stateless 000000000000000000000000000000004 Address 2 0h / -] SettingActive IPv6 Stateless These SPs are the IPv6 status addresses (1 to 5) Address 3 referenced on the Ethernet or wireless LAN (802.11b) in the format: SettingActive IPv6 Stateless Address 4...
  • Page 326 Web shopping link visible *CTL 0: Not display, 1:Display Displays or does not display the link to Net RICOH on the top page and link page of the web system. [Up to 31char / URL1 / 1/step] Web supplies Link visible...
  • Page 327 SP5-722 to 998 (Mode) [HDD Formatting] 5832 Initializes the hard disk. Use this SP mode only if there is a hard disk error. 001 HDD Formatting (ALL) 002 HDD Formatting (IMH) 003 HDD Formatting (Thumbnail) 004 HDD Formatting (Job Log) 005 HDD Formatting (Printer Fonts) [- / - / -] 006 HDD Formatting (User Info1)
  • Page 328 3. Main SP Tables-5 072 Reduction for Copy B&W Text *CTL [0 to 3, 6 / 0 / 1/step] 0: 1to-1 1: 1/2 2: 1/3 073 Reduction for Copy B&W Other *CTL 3: 1/4 6: 2/3 [0 or 3 / 2 / 1/step] 0: 1to-1 074 Reduction for Printer Color *CTL...
  • Page 329 SP5-722 to 998 (Mode) [ 0 to 3 / 1 / 1/step] 083 Format for Copy B&W Other *CTL 0: JFIF/JPEG, 1: TIFF/MMR, 2: TIFF/MH, 3: TIFF/MR 084 Format for Printer Color *CTL [0 / 0 / 1/step] [ 0 to 3 / 1 / 1/step] 085 Format for Printer B&W *CTL 0: JFIF/JPEG, 1: TIFF/MMR,...
  • Page 330 3. Main SP Tables-5 Secondary srv URL path *CTL [0 to 16 char / - / 1/step] This is basically adjusted by the remote system. Default Reso Rate Switch *CTL [0 or 1 / 0 / 1/step] This is basically adjusted by the remote system. Reso: Copy(Color) *CTL [0 to 255 / 3 / 1/step]...
  • Page 331 SP5-722 to 998 (Mode) 5840 [IEEE 802.11] [1 to 14 / 11 (NA), 13 (EU), 14 (JPN) / 1/step] Range Channel Max *CTL JPN: 1 to 14 NA: 1 to 11 EU: 1 to 13 Sets the maximum number of channels available for data transmission via the wireless LAN.
  • Page 332 3. Main SP Tables-5 [1 to 3 / 3 / 1/step] WPA Debug Lvl *CTL 1: Info, 2: warning, 3: error Selects the debug level for WPA authentication application. This SP is displayed only when the IEEE802.11 card is installed. 046 11w *CTL [0 to 2 / 0 / 1/step]...
  • Page 333 SP5-722 to 998 (Mode) [8bit assign / 00000000 / bit switch] 0bit[LSB]: system, other group 1bit: capture related group 2bit: authentication related group 3bit: address book related group 4bit: device management related Setting 1 *CTL group 5bit: output related(print, FAX, and delivery) group 6bit: repository, F0,etc.
  • Page 334 3. Main SP Tables-5 [0 to 2 / 0 / 1/step] 0: OFF 005 Fixed USB Port *CTL 1: Level 1 2: Level 2 [Letters(up to 20) / Laser Printer / -/ 006 PnP Model Name *CTL step] 007 PnP Serial Number *CTL [Letters(up to 12) / - / -/step] [0 or 1 / 1 / 1/step]...
  • Page 335 SP5-722 to 998 (Mode) [0 to 4/ 0 / 1/step] 0: Unknown 1: SG1 Provided Delivery Server Model *CTL 2: SG1 Package 3: SG2 Provided 4: SG2 Package Allows changing the model of the delivery server registered by the I/O device. Delivery Svr.
  • Page 336 3. Main SP Tables-5 Server Port Number (Primary) *CTL [1 to 65535 / 80 / 1/step] This SP is used for the scan router program. Server URL Path (Primary) *CTL [ Up to 16 byte / - / -/step] This SP is used for the scan router program. Server Scheme (Secondary) *CTL [ Up to 6 char / - / -/step]...
  • Page 337 SP5-722 to 998 (Mode) Delivery Server Retry Timer *CTL [0 to 255 / 0 / 1/step] Sets the interval for retry attempts when the delivery server fails to acquire the delivery server address book. Delivery Server Retry Times *CTL [0 to 255 / 0 / 1/step] Sets the number of retry attempts when the delivery server fails to acquire the delivery server address book.
  • Page 338 3. Main SP Tables-5 [- / - / -] Fill Addr Acl Info *CTL [Execute] This SP must be executed immediately after installation of an HDD unit in a basic machine that previously had no HDD. The first time the machine is powered on with the new HDD installed, the system automatically takes the address book from the NVRAM and writes it onto the new HDD.
  • Page 339 SP5-722 to 998 (Mode) [- / - / -] Initialize Delivery Addr Book [Execute] Clears the distribution address book information, except the user code. [- / - / -] Initialize LDAP Addr Book [Execute] Clears the LDAP address book information, except the user code. [- / - / -] Initialize All Addr Book [Execute]...
  • Page 340 3. Main SP Tables-5 Search Option *CTL [0x00 to 0xff / 0x0f/ 1/step] This SP uses bit switches to set up the fuzzy search options for the UCS local address book. Bit: Meaning 0: Checks both upper/lower case characters 1: Japan Only 2: Japan Only 3: Japan Only 4 to 7: Not Used...
  • Page 341 SP5-722 to 998 (Mode) Encryption Stat *CTL [0 to 255 / - / 1/step] Shows the status of the encryption function for the address book data. 5847 [Rep Resolution Reduction] [0 to 5 / 2 / 1/step] 0: x0 1: x1/2 001 Rate for Copy Color *CTL 2: x1/3...
  • Page 342 3. Main SP Tables-5 [0 to 6 / 0 / 1/step] 0: x0 1: x1/2 2: x1/3 005 Rate for Printer B&W *CTL 3: x1/4 4: x1/6 5: x1/8 6: x2/3 [0 to 5 / 4 / 1/step] 0: x0 1: x1/2 006 Rate for Printer Color 1200dpi *CTL...
  • Page 343 SP5-722 to 998 (Mode) [4bit assign / 0000 / bit switch] Accsess Ctrl: Doc. Svr. Print *CTL 0000: No access control (Lower 4bits) 0001: Access control [4bit assign / 0000 / bit switch] Access Ctrl: udirectory (Lower *CTL 0000: No access control 4bits) 0001: Access control [4bit assign / 0000 / bit switch]...
  • Page 344 3. Main SP Tables-5 [4bit assign / 0000 / bit switch] From Right; First bit: For Mac OS Repository: Download Image *CTL Second bit: For Windows OS Setting third bit: Other OS Fourth bit: No Use (0: Setting O, 1: Setting 1) Repository: Download Image *CTL [1 to 2048 / 2048 / 1nByte/step]...
  • Page 345 SP5-722 to 998 (Mode) [0 to 13 / 1 / 1/step]] 1: G3 2: EXT 3: G3-1 4: G3-1- EXT 5: G3-2 6: G3-2- EXT Replacement of Circuit *CTL Classifications 7: G3-3 8: G3-3-EXT 9: G3-idle-EXT 10: idle-EXT 11: I-G3 12: I-G3-EXT 13: G4 5851...
  • Page 346 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 002 Local Port *CTL 0: Disable 1: Enable 5857 [Debug Log Save] Save Debug Log *CTL [0 to 2 / 0 / 1/Step] Enables log trace function or debug log saving function. The debug log cannot be captured until this feature is switched on.
  • Page 347 SP5-722 to 998 (Mode) [- / - / -] Copy HDD to SD Card (Latest *CTL 4MB) [Execute] Takes the most recent 4 MB of the log written to the hard disk and copies them to the SD Card. A unique file name is generated to avoid overwriting existing file names on the SD Card. Up to 4MB can be copied to an SD Card.
  • Page 348 3. Main SP Tables-5 [- / - / -] Copy SD to SD (Latest 4MB Any *CTL Key) [Execute] This SP copies the log on an SD card (the file that contains the information written directly from shared memory) to a log specified by key number. [- / - / -] Make HDD Debug *CTL...
  • Page 349 SP5-722 to 998 (Mode) [- / - / -] Acquire Only Opepanel Debug *CTL Logs [Execute] Outputs the controller debug log to the media inserted front I/F. [Debug Save When] These SPs select the content of the debugging information to be saved to the destination 5858 selected by SP5857-002.
  • Page 350 3. Main SP Tables-5 001 Key 1 *CTL 002 Key 2 *CTL 003 Key 3 *CTL 004 Key 4 *CTL 005 Key 5 *CTL [–9999999 to 9999999 / 0 / 1 / step] 006 Key 6 *CTL 007 Key 7 *CTL 008 Key 8 *CTL...
  • Page 351 SP5-722 to 998 (Mode) [0 to 2 / 0 / 1 /step] 0: Microsoft Outlook Express standard S/MIME: MIME Header *CTL 1: Internet Draft standard 2: RFC standard Selects the MIME header type of an E-mail sent by S/MIME. [0 to 1 / 0 / 1/step] S/MIME: Authentication Check *CTL 0: No (not check)
  • Page 352 3. Main SP Tables-5 [- / - / -] Move Exec [Execute] This SP copies the application programs from the original SD card in SD card slot 2 to an SD card in SD card slot 1. [- / - / -] Undo Exec [Execute] This SP copies back the application programs from an SD card in SD Card Slot 2 to the...
  • Page 353 SP5-722 to 998 (Mode) [- / - / -] 015 Clear UCS Security Setting [Execute] 5878 [Option Setup] [- / - / -] Data Overwrite Security [Execute] Enables the Data Overwrite Security unit. Press "Execute" on the operation panel. Then turn the machine off and on.
  • Page 354 3. Main SP Tables-5 [8bit assign / 00000000 / bit switch] 0: OFF, 1: ON Bit Meaning 0: Forbid all document server access 1: Forbid user mode access (1) 020 DocSvr Acc Ctrl *CTL 2: Forbid print function (1) 3: Forbid fax TX (1) 4: Forbid scan sending (1) 5: Forbid downloading (1) 6: Forbid delete (1)
  • Page 355 SP5-722 to 998 (Mode) [8bit assign / 00000000 / -/step] 0bit: Displays memory status when session time out 200 Detect Mem Leak *CTL 1bit: Displays diff of memory status og when WPF handler’s start/end time. 3 to7bit: Not used. 201 DocSvr Timeout [1 or 30 / 30 / 1/step] 5887 [SD GetCounter]...
  • Page 356 3. Main SP Tables-5 [- / - / -] 002 SDK-2 [Display text] [- / - / -] 003 SDK-3 [Display text] [- / - / -] 004 SDK-4 [Display text] [- / - / -] 005 SDK-5 [Display text] [- / - / -] 006 SDK-6 [Display text]...
  • Page 357 SP5-722 to 998 (Mode) Trigger *ENG [0 to 3 / 0 / 1/step] Specifying Target Trigger group for Engine Log Upload. 5907 [Plug & Play Maker/Model Name] Plug & Play Maker/Model/ *CTL [- / - / -] Name Selects the brand name and the production name for Windows Plug & Play. This information is stored in the NVRAM.
  • Page 358 3. Main SP Tables-5 Tray2:1 *ENG [0 or 1 / 0 / 1/step] Size settings for Tray 2 Tray2:2 *ENG [0 or 1 / 0 / 1/step] Size settings for Tray 2 Tray2:3 *ENG [0 or 1 / 0 / 1/step] Size settings for Tray 2 Tray2:4 *ENG...
  • Page 359 SP5-722 to 998 (Mode) Tray4:2 *ENG [0 or 1 / 0 / 1/step] Size settings for Tray 4 Tray4:3 *ENG [0 or 1 / 0 / 1/step] Size settings for Tray 4 Tray4:4 *ENG [0 or 1 / 0 / 1/step] Size settings for Tray 4 Tray4:5 *ENG...
  • Page 360 3. Main SP Tables-5 [0 or 1 / 0 / 1/step] 001 (0: ON 1: OFF) *CTL 0: ON 1: OFF 5974 [Cherry Server] 001 (0: Light 1: Full) *CTL [ - / - / -] [Device Setting] The NIC and USB support features are built into the GW controller. Use this SP to enable 5985 and disable these features.
  • Page 361 SP5-722 to 998 (Mode) [SP Print Mode] 5990 Prints out the SMC sheets. 001 All(Data List) 002 SP(Mode Data List) 003 User Program [- / - / -] 004 Logging Data [Execute] 005 Diagnostic Report 006 Non-Default 007 NIB Summary 008 Capture Log 021 Copier User Program 022 Scanner SP...
  • Page 362 3. Main SP Tables-5 001 All(Data List) 002 SP(Mode Data List) 003 User Program 004 Logging Data 005 Diagnostic Report 006 Non-Default 007 NIB Summary [- / - / -] [Execute] 008 Capture Log 021 Copier User Program 022 Scanner SP 023 Scanner User Program 024 SDK/J Summary 025 SDK/J Application Info...
  • Page 363: Main Sp Tables-6

    4. Main SP Tables-6 SP6-XXX (Peripherals) 6006 [ADF Adjustment] Side-to-Side Regist: Front *ENG [-3.0 to 3.0 / 0.0 / 0.1 mm/step] Executes ADF Adjustment for Front Side-to-Side Regist. Side-to-Side Regist: Rear *ENG [-3.0 to 3.0 / 0.0 / 0.1 mm/step] Executes ADF Adjustment for Rear Side-to-Side Regist.
  • Page 364 4. Main SP Tables-6 T-Edge Erase (1-Pass): Front *ENG [-5.0 to 5.0 / -1.5 / 0.1 mm/step] Executes Front T-Edge Regist Adjustment. • Value increase: Increases Image T-Edge. • Value decrease: Delete Image T-Edge. Corrects it into the maximum value within adjustable range if the value which exceeds the range is set.
  • Page 365 SP6-XXX (Peripherals) [1-Pass ADF INPUT Check] 6011 See page 671 [1-Pass ADF OUTPUT Check] 6012 See page 741 [Original Size Detect Setting] Sets which original size is to be determined in regard to the two original sizes which are 6016 impossible to be determined in ADF.
  • Page 366 4. Main SP Tables-6 [- / - / -] Hinge Open Counter Clear [Execute] SP6-030-001: Resets the counter for opening and closing of DF hinge part. [Sub-scanPunchPosAdj:2K/3K FIN] Adjusts the position for Length (Sub Scan) for Punch. • Adjustment Value "-": Whole position shifts to the direction of the paper trailing edge 6100 when accepted.
  • Page 367 SP6-XXX (Peripherals) [SkewCorrectBuckleAdj:2K/3K FIN] Adjusts Skew Correction Buckle when punching specified papers. 6102 • Adjustment Value "-": Buckle decreases. • Adjustment Value "+": Buckle increases. 001 A3 SEF *ENG 002 B4 SEF *ENG 003 A4 SEF *ENG [-5.0 to 5.0 / 0.0 / 0.2mm/step] 004 A4Y *ENG 005 B5T...
  • Page 368 4. Main SP Tables-6 [SkewCorrectCtrlSW:2K/3K FIN] 6103 Switches Skew Correction Control (Stop Skew Correction ON/OFF) when punching specified papers. 001 A3 SEF *ENG 002 B4 SEF *ENG 003 A4 SEF *ENG [0 or 1 / 0 / 1/step] 004 A4Y *ENG 005 B5T *ENG...
  • Page 369 SP6-XXX (Peripherals) [ShiftTrayJogPosAdj:2K/3K FIN] Adjusts the position for moving direction (Main Scan) of Shift Tray Jogger when feeding papers other than specified papers. 6104 • Adjustment Value "-": Movement in the direction that Shift Tray Jogger width becomes narrower than the standard value, •...
  • Page 370 4. Main SP Tables-6 [ShftTJogRtrctAngAdj:2K/3K FIN] Adjusts Shift Tray Jogger Retract Angle when feeding specified papers. 6105 • Adjustment Value "+": Upper direction, • Adjustment Value "-": Lower direction. 001 A3 SEF *ENG 002 B4 SEF 003 A4 SEF 004 DLT SEF [-10 to 10 / 0 / 5 deg/step] 005 LG SEF 006 LT SEF...
  • Page 371 SP6-XXX (Peripherals) 005 B5Y *ENG 006 A5Y *ENG 007 DLT SEF *ENG [0 or 1 / 0 / 1/step] 008 LG SEF *ENG 009 LT SEF *ENG 010 LT-Y *ENG 011 HLT-Y *ENG [0 or 1 / 0 / 1/step] 012 8-Kai SEF *ENG 013 16-Kai LEF...
  • Page 372 4. Main SP Tables-6 005 B5T *ENG 006 B5Y *ENG 007 DLT SEF *ENG [-1.5 to 1.5 / 0.0 / 0.5mm/step] 008 LG SEF *ENG 009 LT SEF *ENG 010 LT-Y *ENG 011 8-Kai SEF *ENG 012 16-Kai SEF *ENG [-1.5 to 1.5 / 0.0 / 0.5mm/step] 013 16-Kai LEF *ENG...
  • Page 373 SP6-XXX (Peripherals) 001 A3 SEF *ENG 002 B4 SEF *ENG 003 A4 SEF *ENG 004 B5T *ENG 005 DLT SEF *ENG [-1.5 to 1.5 / 0.0 / 0.5mm/step] 006 LG SEF *ENG 007 LT SEF *ENG 008 12"*18" *ENG 009 8-Kai SEF *ENG 010 Other *ENG...
  • Page 374 4. Main SP Tables-6 011 8-Kai SEF *ENG 012 16-Kai SEF *ENG [0 to 2 / 0 / 1 time/step] 013 16-Kai LEF *ENG Other *ENG [0 to 2 / 0 / 1 time/step] Adjusts jogging time for Corner Stapler Jogger Fence when jogging specified papers (Only the last paper).
  • Page 375 SP6-XXX (Peripherals) 001 A3 SEF *ENG 002 B4 SEF [-3.5 to 3.5 / 0.0 / 0.5mm/step] 003 A4 SEF 004 A4Y 005 B5T 006 B5Y 007 DLT SEF [-3.5 to 3.5 / 0.0 / 0.5mm/step] 008 LG SEF 009 LT SEF 010 LT-Y 011 8-Kai SEF 012 16-Kai SEF...
  • Page 376 4. Main SP Tables-6 005 DLT SEF *ENG [-3.0 to 3.0 / 0.0 / 0.2mm/step] 006 LG SEF *ENG [-3.0 to 3.0 / 0.0 / 0.2mm/step] 007 LT SEF *ENG [-3.0 to 3.0 / 0.0 / 0.2mm/step] 008 12"x18" *ENG [-1.8 to 1.8 / 0.0 / 0.2mm/step] 009 8-Kai SEF *ENG...
  • Page 377 SP6-XXX (Peripherals) Other *ENG [-3.0 to 3.0 / 0.0 / 0.2mm/step] Adjusts folding position (Sub Scan direction) for Booklet Folder for specified papers. • Adjustment Value "-": Staple position shifts to the direction of the paper trailing edge when accepted. •...
  • Page 378 4. Main SP Tables-6 Free Run 1 [0 or 1 / 0 / 1/step] Executes Free Run in Shift Mode: No Paper. Free Run 2 [0 or 1 / 0 / 1/step] Executes Free Run in Corner Stapler Mode: No Paper. Free Run 3 [0 or 1 / 0 / 1/step] Executes Free Run in Book Stapler Mode: No Paper.
  • Page 379 SP6-XXX (Peripherals) Other [-1 to 0 / 0 / 1 page/step] Adjusts Maximum Pre-Stack Number for Corner Stapler for specified papers. Adjustment value: 0; 1 sheet Pre-Stack (Standard), Adjustment value: -1: No Pre-Stack. [BookStplrMxPrstkShAdj:2K/3KFIN] Adjusts Maximum Pre-Stack Number for Book Stapler for specified papers. Adjustment value: 0;...
  • Page 380 4. Main SP Tables-6 [CrnrStplrPrstkOffsAdj:2K/3KFIN] Adjusts Pre-Stack Offset (Offset of 1st page from 2nd page in Sub Scan direction) for 6118 Corner Stapler for specified papers. There is 20mm offset by default. "+" Adjustment Value is the direction that offset increases, and "-"...
  • Page 381 SP6-XXX (Peripherals) [BookStplrPrstkOffsAdj:2K/3KFIN] Adjusts Pre-Stack Offset (Offset of 1st page from 2nd page, and of 2nd page from 3rd page in Sub Scan direction) for Book Stapler for specified papers. There is no offset by 6119 default. "+" Adjustment Value is the direction that offset increases, and "-"...
  • Page 382 4. Main SP Tables-6 005 B5T 006 B5Y 007 DLT SEF [0 to 30 / 0 / 10mm/step] 008 LG SEF 009 LT SEF 010 LT-Y 011 8-Kai SEF 012 16-Kai SEF [0 to 30 / 0 / 10mm/step] 013 16-Kai LEF Other Adjusts Positioning Roller ExFeedAmt (Sub Scan direction) for Corner Stapler for specified papers.
  • Page 383 SP6-XXX (Peripherals) 005 DLT SEF 006 LG SEF 007 LT SEF [-5 to 5 / 0 / 2mm/step] 008 12"*18" 009 8-Kai SEF Other Adjusts Booklet Folder JogSolMovAmt for Book Stapler for specified papers. • Adjustment Value "+": Upper direction, •...
  • Page 384 4. Main SP Tables-6 002 B4 SEF [-2.0 to 1.5 / 0.0 / 0.5mm/step] 003 A4 SEF [-2.0 to 1.5 / 0.0 / 0.5mm/step] 004 A4Y [-2.0 to 1.5 / 0.0 / 0.5mm/step] 005 B5T [-2.0 to 1.5 / 0.0 / 0.5mm/step] 006 B5Y [-2.0 to 1.5 / 0.0 / 0.5mm/step] 007 DLT SEF...
  • Page 385 SP6-XXX (Peripherals) 001 A3 SEF [-3.0 to 3.0 / 0.0 / 0.1mm/step] 002 B4 SEF [-3.0 to 3.0 / 0.0 / 0.1mm/step] 003 A4 SEF [-3.0 to 3.0 / 0.0 / 0.1mm/step] 004 A4Y [-3.0 to 3.0 / 0.0 / 0.1mm/step] 005 B5T [-3.0 to 3.0 / 0.0 / 0.1mm/step] 006 B5Y...
  • Page 386 4. Main SP Tables-6 [LE StopPressAdj:3KFIN(100Bind)] 6145 Executes adjustment of Leading Edge Stopper Press. 001 A4Y [-5.0 to 10.0 / 0.0 / 0.1mm/step] 002 B5Y [-5.0 to 2.0 / 0.0 / 0.1mm/step] 003 LT-Y [-5.0 to 10.0 / 0.0 / 0.1mm/step] 004 Other [-5.0 to 10.0 / 0.0 / 0.1mm/step] [StapleJogTimes: 3KFIN(100Bind)]...
  • Page 387 SP6-XXX (Peripherals) 001 A3SEF/12"*18" [0 or 1 / 0 / 1/step] 002 EU/CHN/Taiwan:8.5"*13" [0 or 1 / 0 / 1/step] 003 NA:8.5"*14" [0 or 1 / 0 / 1/step] 004 NA:11"*8.5" [0 or 1 / 0 / 1/step] 005 NA:8.5"*11" [0 or 1 / 0 / 1/step] 006 EU/CHN/Taiwan:8K [0 or 1 / 0 / 1/step]...
  • Page 388 4. Main SP Tables-6 004 DLT SEF [-4.0 to 4.0 / 0.0 / 0.2mm/step] 005 LG SEF [-4.0 to 4.0 / 0.0 / 0.2mm/step] 006 LT SEF [-4.0 to 4.0 / 0.0 / 0.2mm/step] 007 12"*18" [-4.0 to 4.0 / 0.0 / 0.2mm/step] 008 Other [-4.0 to 4.0 / 0.0 / 0.2mm/step] [Fine Adjust Z-Fold 1]...
  • Page 389 SP6-XXX (Peripherals) Free Run 3 [0 or 1 / 0 / 1/step] No Paper Free Run (Straight Transport) operation Free Run 4 [0 or 1 / 0 / 1/step] Makes drive load do homing for packing. [FM1 Z-Fld: Fine Adj 1st Fld] Adjusts Z-Fold end (S) when Z-folding by using Folding Unit.
  • Page 390 4. Main SP Tables-6 [FM1 Z-Fld: Fine Adj 2nd Fld] Adjusts Z-Fold Outer Frame size (L) when Z-folding by using Folding Unit. [+] makes (L) large and [-] makes (L) small. The cercle is the leading edge of paper, and the dot is the trailing edge of paper. 6313 paper feeding direction * Only enabled when Custom Paper is not being used in Pro machine.
  • Page 391 SP6-XXX (Peripherals) [FM2 Equal 1/2:FineAdjFld] Adjusts End (S) when half-folding by using Folding Unit. [+] makes (S) large and [-] makes (S) small. Turns to be enabled when Single Sheet is specified. The cercle is the leading edge of paper, and the dot is the trailing edge of paper. 6314 paper feeding direction * Only enabled when Custom Paper is not being used in Pro machine.
  • Page 392 4. Main SP Tables-6 [FM2 Equal 1/2:FineAdjFld] Adjusts End (S) when half-folding by using Folding Unit. [+] makes (S) large and [-] makes (S) small. Turns to be enabled when Multi Sheet is specified. The cercle is the leading edge of paper, and the dot is the trailing edge of paper. 6314 paper feeding direction * This setting is synchronized with Adjustment Items for Special Operator [Half Fold Position...
  • Page 393 SP6-XXX (Peripherals) [FM3 Equal 3rds:Fine Adj 1st] Adjusts End (S2) when folding with Letter Fold-out by using Folding Unit. [+] makes (S2) large and [-] makes (S2) small. Turns to be enabled when Single Sheet is specified. The cercle is the leading edge of paper, and the dot is the trailing edge of paper. 6315 paper feeding direction * Only enabled when Custom Paper is not being used in Pro machine.
  • Page 394 4. Main SP Tables-6 [FM3 Equal 3rds:Fine Adj 1st] Adjusts End (S2) when folding with Letter Fold-out by using Folding Unit. [+] makes (S2) large and [-] makes (S2) small. Turns to be enabled when Multi Sheet is specified. The cercle is the leading edge of paper, and the dot is the trailing edge of paper. 6315 paper feeding direction * This setting is synchronized with Adjustment Items for Special Operator [Letter Fold-out...
  • Page 395 SP6-XXX (Peripherals) 001 A3 SEF (Single Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step] 002 B4 SEF (Single Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step] 003 A4 SEF (Single Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step] 004 DLT SEF (Single Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step] 005 LG SEF (Single Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 396 4. Main SP Tables-6 [FM4 3rds 1 Flap:Fine Adj 1st] Adjusts End (S) when folding with Letter Fold-in by using Folding Unit. [+] makes (S) large and [-] makes (S) small. Turns to be enabled when Single Sheet is specified. The cercle is the leading edge of paper, and the dot is the trailing edge of paper.
  • Page 397 SP6-XXX (Peripherals) 022 B4 SEF (Multi Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step] 023 A4 SEF (Multi Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step] 024 DLT SEF (Multi Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step] 025 LG SEF (Multi Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step] 026 LT SEF (Multi Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 398 4. Main SP Tables-6 008 8-kai (Single Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step] 009 B5 SEF (Single Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step] 019 Custom (Single Sheet) [-4.0 to 4.0 / 0.0 / 0.2mm/step] [FM4 3rds 1 Flap:Fine Adj 2nd] Adjusts Inner Frame size (L) when folding with Letter Fold-in by using Folding Unit.
  • Page 399 SP6-XXX (Peripherals) [FM5 4ths "V": Fine Adjust 1st] Adjusts End (S1) position when folding with Double Parallel Fold by using Folding Unit. [+] makes (S1) large and [-] makes (S1) small. The top right illustration shows the status that Double Parallel Fold is opened (Half Fold) and the bottom right one shows that Double Parallel Fold is not opened.
  • Page 400 4. Main SP Tables-6 [FM5 4ths "V": Fine Adjust 2nd] Adjusts End2 (S2) position when folding with Double Parallel Fold by using Folding Unit. [+] makes (S2) large and [-] makes (S2) small. The top right illustration shows the status that Double Parallel Fold is opened and the bottom right one shows that Double Parallel Fold is not opened.
  • Page 401 SP6-XXX (Peripherals) [FM6 4ths 2 Flap:Fine Adj 1st] Adjusts End (S1) position when folding with Gate Fold by using Folding Unit. [+] makes (S1) large and [-] makes (S1) small. The top right illustration shows the status that Gate Fold is opened and the bottom right one shows that Gate Fold is not opened.
  • Page 402 4. Main SP Tables-6 [FM6 4ths 2 Flap:Fine Adj 2nd] Adjusts End2 (S2) position when folding with Gate Fold by using Folding Unit. [+] makes (S2) large and [-] makes (S2) small. The top right illustration shows the status that Gate Fold is opened and the bottom right one shows that Gate Fold is not opened.
  • Page 403 SP6-XXX (Peripherals) [FM6 4ths 2 Flap:Fine Adj 3rd] Adjusts Center (S3) position when folding with Gate Fold by using Folding Unit. [+] makes (S3) large and [-] makes (S3) small. The top right illustration shows the status that Gate Fold is opened and the bottom right one shows that Gate Fold is not opened.
  • Page 404 4. Main SP Tables-6 001 A3 SEF [-2.0 to 2.0 / 0.0 / 0.5mm/step] 002 B4 SEF [-2.0 to 2.0 / 0.0 / 0.5mm/step] 003 A4 SEF [-2.0 to 2.0 / 0.0 / 0.5mm/step] 004 DLT SEF [-2.0 to 2.0 / 0.0 / 0.5mm/step] 005 LG SEF [-2.0 to 2.0 / 0.0 / 0.5mm/step] 006 LT SEF...
  • Page 405 SP6-XXX (Peripherals) 009 B5T [-4 to 2 / 0 / 1mm/step] 019 Other [-4 to 2 / 0 / 1mm/step] [Reg Buckle Adjust Select] 6326 Specifies ON/OFF for Registration Correction when folding with Single Sheet by using Folding Unit. 001 - [0 or 1 / 0 / 1/step] [Cvr Inserter INPUT Check] 6400...
  • Page 406 4. Main SP Tables-6 013 Custom Paper 013 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 407 SP6-XXX (Peripherals) 039 Custom Paper 039 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044...
  • Page 408 4. Main SP Tables-6 065 Custom Paper 065 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 409 SP6-XXX (Peripherals) 091 Custom Paper 091 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096...
  • Page 410 4. Main SP Tables-6 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 018 Custom Paper 018 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 411 SP6-XXX (Peripherals) 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 045 Custom Paper 045...
  • Page 412 4. Main SP Tables-6 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 070 Custom Paper 070 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 413 SP6-XXX (Peripherals) 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 097 Custom Paper 097...
  • Page 414 4. Main SP Tables-6 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 018 Custom Paper 018 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 415 SP6-XXX (Peripherals) 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 045 Custom Paper 045...
  • Page 416 4. Main SP Tables-6 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 070 Custom Paper 070 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 417 SP6-XXX (Peripherals) 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 097 Custom Paper 097...
  • Page 418 4. Main SP Tables-6 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 018 Custom Paper 018 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 419 SP6-XXX (Peripherals) 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 045 Custom Paper 045...
  • Page 420 4. Main SP Tables-6 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 070 Custom Paper 070 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 421 SP6-XXX (Peripherals) 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 097 Custom Paper 097...
  • Page 422 4. Main SP Tables-6 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 018 Custom Paper 018 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 423 SP6-XXX (Peripherals) 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 045 Custom Paper 045...
  • Page 424 4. Main SP Tables-6 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 070 Custom Paper 070 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 425 SP6-XXX (Peripherals) 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 097 Custom Paper 097...
  • Page 426 4. Main SP Tables-6 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 018 Custom Paper 018 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 427 SP6-XXX (Peripherals) 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 045 Custom Paper 045...
  • Page 428 4. Main SP Tables-6 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 070 Custom Paper 070 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 429 SP6-XXX (Peripherals) 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 097 Custom Paper 097...
  • Page 430 4. Main SP Tables-6 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 018 Custom Paper 018 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 431 SP6-XXX (Peripherals) 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 045 Custom Paper 045...
  • Page 432 4. Main SP Tables-6 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 070 Custom Paper 070 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 433 SP6-XXX (Peripherals) 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 097 Custom Paper 097...
  • Page 434 4. Main SP Tables-6 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 018 Custom Paper 018 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 435 SP6-XXX (Peripherals) 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 045 Custom Paper 045...
  • Page 436 4. Main SP Tables-6 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 070 Custom Paper 070 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 437 SP6-XXX (Peripherals) 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 097 Custom Paper 097...
  • Page 438 4. Main SP Tables-6 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 018 Custom Paper 018 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 439 SP6-XXX (Peripherals) 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 045 Custom Paper 045...
  • Page 440 4. Main SP Tables-6 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 070 Custom Paper 070 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 441 SP6-XXX (Peripherals) 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 097 Custom Paper 097...
  • Page 442 4. Main SP Tables-6 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 018 Custom Paper 018 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 443 SP6-XXX (Peripherals) 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 045 Custom Paper 045...
  • Page 444 4. Main SP Tables-6 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 070 Custom Paper 070 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 445 SP6-XXX (Peripherals) 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 097 Custom Paper 097...
  • Page 446 4. Main SP Tables-6 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 018 Custom Paper 018 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 447 SP6-XXX (Peripherals) 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 045 Custom Paper 045...
  • Page 448 4. Main SP Tables-6 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 070 Custom Paper 070 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 449 SP6-XXX (Peripherals) 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 097 Custom Paper 097...
  • Page 450 4. Main SP Tables-6 014 Custom Paper 014 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 015 Custom Paper 015 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 016 Custom Paper 016 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 017 Custom Paper 017 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 018 Custom Paper 018 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 451 SP6-XXX (Peripherals) 040 Custom Paper 040 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 041 Custom Paper 041 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 042 Custom Paper 042 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 043 Custom Paper 043 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 044 Custom Paper 044 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 045 Custom Paper 045...
  • Page 452 4. Main SP Tables-6 066 Custom Paper 066 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 067 Custom Paper 067 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 068 Custom Paper 068 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 069 Custom Paper 069 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 070 Custom Paper 070 [-4.0 to 4.0 / 0.0 / 0.2mm/step]...
  • Page 453 SP6-XXX (Peripherals) 092 Custom Paper 092 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 093 Custom Paper 093 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 094 Custom Paper 094 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 095 Custom Paper 095 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 096 Custom Paper 096 [-4.0 to 4.0 / 0.0 / 0.2mm/step] 097 Custom Paper 097...
  • Page 454 4. Main SP Tables-6 001 - [0 to 250 / 0 / 1/step] [1-pass Stamp Unit] 6801 Sets Attached/Not Attached for Stamp Unit. [0 or 1 / 0 / 1/step] 001 - *ENG 0: Attached 1: Not Attached [Extra Staples] More than the standard number of sheets can be stapled.
  • Page 455 SP6-XXX (Peripherals) [1 to 0 / 0 / 1/step] 001 0: No Punch 1: Punching OK 0: No Punch 1: Punching OK [ADF Bottom Plate Setting] 6900 Changes Bottom Plate Mode. [0 or 1 / 0 / 1/step] 0: Bottom Plate (Default) by Original set 001 - *ENG 1: Bottom Plate by Feed/Exit Paper...
  • Page 456 4. Main SP Tables-6 002 Custom Paper002 [1 to 5 / 1 / 1/step] 003 Custom Paper003 [1 to 5 / 1 / 1/step] 004 Custom Paper004 [1 to 5 / 1 / 1/step] 005 Custom Paper005 [1 to 5 / 1 / 1/step] 006 Custom Paper006 [1 to 5 / 1 / 1/step] 007 Custom Paper007...
  • Page 457 SP6-XXX (Peripherals) 028 Custom Paper028 [1 to 5 / 1 / 1/step] 029 Custom Paper029 [1 to 5 / 1 / 1/step] 030 Custom Paper030 [1 to 5 / 1 / 1/step] 031 Custom Paper031 [1 to 5 / 1 / 1/step] 032 Custom Paper032 [1 to 5 / 1 / 1/step] 033 Custom Paper033...
  • Page 458 4. Main SP Tables-6 054 Custom Paper054 [1 to 5 / 1 / 1/step] 055 Custom Paper055 [1 to 5 / 1 / 1/step] 056 Custom Paper056 [1 to 5 / 1 / 1/step] 057 Custom Paper057 [1 to 5 / 1 / 1/step] 058 Custom Paper058 [1 to 5 / 1 / 1/step] 059 Custom Paper059...
  • Page 459 SP6-XXX (Peripherals) 080 Custom Paper080 [1 to 5 / 1 / 1/step] 081 Custom Paper081 [1 to 5 / 1 / 1/step] 082 Custom Paper082 [1 to 5 / 1 / 1/step] 083 Custom Paper083 [1 to 5 / 1 / 1/step] 084 Custom Paper084 [1 to 5 / 1 / 1/step] 085 Custom Paper085...
  • Page 460 4. Main SP Tables-6 [SoftRollerPress QuantityTuning] *D137/D138 only Fine-tunes Decurler Roller Pressure ranging from +0.5 - -0.3mm with Custom Paper. • Increases or decreases the specified value to the pressure in Decurler Pressure level 6929 (Level 1-5). • Plus value: Curl UP Correction •...
  • Page 461 SP6-XXX (Peripherals) 022 Custom Paper022 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 023 Custom Paper023 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 024 Custom Paper024 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 025 Custom Paper025 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 026 Custom Paper026 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 027 Custom Paper027...
  • Page 462 4. Main SP Tables-6 048 Custom Paper048 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 049 Custom Paper049 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 050 Custom Paper050 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 051 Custom Paper051 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 052 Custom Paper052 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 053 Custom Paper053...
  • Page 463 SP6-XXX (Peripherals) 074 Custom Paper074 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 075 Custom Paper075 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 076 Custom Paper076 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 077 Custom Paper077 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 078 Custom Paper078 [-0.3 to 0.5 / 0.0 / 0.1mm/step] 079 Custom Paper079...
  • Page 464 4. Main SP Tables-6 100 Custom Paper100 [-0.3 to 0.5 / 0.0 / 0.1mm/step]...
  • Page 465: Main Sp Tables-7

    5. Main SP Tables-7 SP7-001 to 931 (Data Log) [Engine Drive Distance Counter] 7001 Displays Engine Drive Distance Counter. 001 #PCU:K [0 to 99999999 / 0 / 1m/step] [Total SC] Stores total SC occurring count. 7401 If the same SC codes are detected continuously and total counter is not increasing, it only logs once in case of deleting other SC code logs.
  • Page 466 5. Main SP Tables-7 001 Latest *CTL 002 Latest 1 *CTL 003 Latest 2 *CTL 004 Latest 3 *CTL 005 Latest 4 *CTL [- / - / -] 006 Latest 5 *CTL 007 Latest 6 *CTL 008 Latest 7 *CTL 009 Latest 8 *CTL 010 Latest 9...
  • Page 467 SP7-001 to 931 (Data Log) [Total Paper Jam] 7502 Displays the total number of jams detected. Jam Counter *CTL [00000 to 65535 / - / 1sheet/step] If the JAM occurred in multiple places, it logs as one SC. 002 Total Jam Counter *CTL [Total Original Jam Counter] 7503...
  • Page 468 5. Main SP Tables-7 016 LCT Exit: On *CTL [0000 to 9999 / - / 1/step] 017 LCT Relay: On *CTL [0000 to 9999 / - / 1/step] 018 Main Unit Relay: On *CTL [0000 to 9999 / - / 1/step] 019 Registration: On *CTL [0000 to 9999 / - / 1/step]...
  • Page 469 SP7-001 to 931 (Data Log) 067 LCT Relay: Off *CTL [0000 to 9999 / - / 1/step] 068 Main Unit Relay: Off *CTL [0000 to 9999 / - / 1/step] 069 Registration Sensor: Off *CTL [0000 to 9999 / - / 1/step] 072 TH Transport: Off *CTL [0000 to 9999 / - / 1/step]...
  • Page 470 5. Main SP Tables-7 104 Shift Tray Exit: On *CTL [0000 to 9999 / - / 1/step] 105 Shift Tray Exit: Off *CTL [0000 to 9999 / - / 1/step] 106 Stapler Exit: On *CTL [0000 to 9999 / - / 1/step] 107 Stapler Exit: Off *CTL [0000 to 9999 / - / 1/step]...
  • Page 471 SP7-001 to 931 (Data Log) 157 Shift Tray Exit *CTL [0000 to 9999 / - / 1/step] 158 Booklet Stapler Exit *CTL [0000 to 9999 / - / 1/step] 159 Entrance Motor *CTL [0000 to 9999 / - / 1/step] 160 Horizontal Transport Mortor *CTL [0000 to 9999 / - / 1/step]...
  • Page 472 5. Main SP Tables-7 182 Press-Fold Motor *CTL [0000 to 9999 / - / 1/step] 183 Tray Lift Motor *CTL [0000 to 9999 / - / 1/step] 184 Shift Motor *CTL [0000 to 9999 / - / 1/step] 185 Shift Jogger Front Motor *CTL [0000 to 9999 / - / 1/step] 186 Shift Jogger Rear Motor...
  • Page 473 SP7-001 to 931 (Data Log) 217 Stopper Motor 3 Error *CTL [0000 to 9999 / - / 1/step] 218 Dynamic Roller Lift Mt Error *CTL [0000 to 9999 / - / 1/step] 219 Regist Roller Release Mt Error *CTL [0000 to 9999 / - / 1/step] 220 Fold Plate Motor Error *CTL [0000 to 9999 / - / 1/step]...
  • Page 474 5. Main SP Tables-7 066 Registration Sensor: Off *CTL [0000 to 9999 / - / 1/step] 067 Original Exit Sensor: Off *CTL [0000 to 9999 / - / 1/step] 239 Original Pull *CTL [0000 to 9999 / - / 1/step] [Jam Count by Paper Size] 7506 Displays the number of jams according to the paper size.
  • Page 475 SP7-001 to 931 (Data Log) 001 Latest *CTL 002 Latest 1 *CTL 003 Latest 2 *CTL 004 Latest 3 *CTL 005 Latest 4 *CTL [- / - / -] 006 Latest 5 *CTL 007 Latest 6 *CTL 008 Latest 7 *CTL 009 Latest 8 *CTL...
  • Page 476 5. Main SP Tables-7 001 Up Stopper Sensor: Late *CTL 002 Up Stopper Sensor: Lag *CTL 003 Lower Ex Sensor1: Late *CTL 004 Lower Ex Sensor1: Lag *CTL 005 Exit Sensor 3: Late *CTL [- / - / -] 006 Exit Sensor 3: Lag *CTL 007 Brushless Motor *CTL...
  • Page 477 SP7-001 to 931 (Data Log) 050 1st Pullout Sensor: Lag *CTL 051 2nd Pullout Sensor: Late *CTL 052 2nd Pullout Sensor: Lag *CTL 053 1st Vertical Transport Sensor: Late *CTL 054 1st Vertical Transport Sensor: Lag *CTL [- / - / -] 055 2nd Vertical Transport Sensor: Late *CTL 056 2nd Vertical Transport Sensor: Lag...
  • Page 478 5. Main SP Tables-7 100 Transport Sensor 3: Lag *CTL 101 Transport Sensor 4: Late *CTL 102 Transport Sensor 4: Lag *CTL [- / - / -] 103 Transport Sensor 5: Late *CTL 104 Transport Sensor 5: Lag *CTL 105 Main Machine Settin Incorrect *CTL Cover Feeder: Paper Set Sensor : *CTL...
  • Page 479 SP7-001 to 931 (Data Log) 158 Relay Sensor 7: Lag *CTL [- / - / -] 159 Relay Sensor 8: Late *CTL [- / - / -] 160 Relay Sensor 8: Lag *CTL [- / - / -] 161 Main Machine Setting Incorrect *CTL [- / - / -] [Paper Jam Count by Location]...
  • Page 480 5. Main SP Tables-7 022 TH Transport: On *CTL [0000 to 9999 / - / 1/step] 024 Fusing Exit: On *CTL [0000 to 9999 / - / 1/step] 025 Inverter Entrance: On *CTL [0000 to 9999 / - / 1/step] 026 Paper Exit Inverter: On *CTL [0000 to 9999 / - / 1/step]...
  • Page 481 SP7-001 to 931 (Data Log) 074 Fusing Exit: Off *CTL [0000 to 9999 / - / 1/step] 075 Inverter Entrance: Off *CTL [0000 to 9999 / - / 1/step] 076 Paper Exit Inverter: Off *CTL [0000 to 9999 / - / 1/step] 078 Inverter Exit: Off *CTL [0000 to 9999 / - / 1/step]...
  • Page 482 5. Main SP Tables-7 108 Pre-Stack: On *CTL [0000 to 9999 / - / 1/step] 109 Pre-Stack: Off *CTL [0000 to 9999 / - / 1/step] 110 Feed Out *CTL [0000 to 9999 / - / 1/step] 111 Motors *CTL [0000 to 9999 / - / 1/step] 112 Tray Lift Motor *CTL...
  • Page 483 SP7-001 to 931 (Data Log) 161 Pre-Stack Transport Motor *CTL [0000 to 9999 / - / 1/step] 162 Relay Motor *CTL [0000 to 9999 / - / 1/step] 163 Paper Exit Motor *CTL [0000 to 9999 / - / 1/step] 164 Trailing Edge Stack Plate Motor *CTL [0000 to 9999 / - / 1/step]...
  • Page 484 5. Main SP Tables-7 186 Shift Jogger Rear Motor *CTL [0000 to 9999 / - / 1/step] 187 Shift Jogger Retraction Motor *CTL [0000 to 9999 / - / 1/step] 188 Drag Roller Oscillating Motor *CTL [0000 to 9999 / - / 1/step] 189 Leading Edge Guide Motor *CTL [0000 to 9999 / - / 1/step]...
  • Page 485 SP7-001 to 931 (Data Log) 221 Jogger Fence Motor Error *CTL [0000 to 9999 / - / 1/step] 222 Direct-Send JG Motor Error *CTL [0000 to 9999 / - / 1/step] 223 FM6 Pawl Motor Error *CTL [0000 to 9999 / - / 1/step] 249 Main Machine Setting Incorrect *CTL [0000 to 9999 / - / 1/step]...
  • Page 486 5. Main SP Tables-7 [Jam Paper Size Cnt] 7516 Displays occurring count of transfer paper jams by each paper size. 005 A4 LEF *CTL 006 A5 LEF *CTL 014 B5 LEF *CTL [0 to 9999 / 0 / 1 sheets/step] 038 LT LEF *CTL 044 HLT LEF...
  • Page 487 SP7-001 to 931 (Data Log) 001 Up Stopper Sensor: Late *CTL 002 Up Stopper Sensor: Lag *CTL 003 Lower Ex Sensor1: Late *CTL 004 Lower Ex Sensor1: Lag *CTL 005 Exit Sensor 3: Late *CTL [- / - / -] 006 Exit Sensor 3: Lag *CTL 007 Brushless Motor...
  • Page 488 5. Main SP Tables-7 050 1st Pullout Sensor: Lag *CTL 051 2nd Pullout Sensor: Late *CTL 052 2nd Pullout Sensor: Lag *CTL 053 1st Vertical Transport Sensor: Late *CTL 054 1st Vertical Transport Sensor: Lag *CTL [- / - / -] 055 2nd Vertical Transport Sensor: Late *CTL 056 2nd Vertical Transport Sensor: Lag...
  • Page 489 SP7-001 to 931 (Data Log) 100 Transport Sensor 3: Lag *CTL 101 Transport Sensor 4: Late *CTL 102 Transport Sensor 4: Lag *CTL [- / - / -] 103 Transport Sensor 5: Late *CTL 104 Transport Sensor 5: Lag *CTL 105 Main Machine Setting Incorrect *CTL Cover Feeder: Paper Set Sensor :...
  • Page 490 5. Main SP Tables-7 158 Relay Sensor 7: Lag *CTL [- / - / -] 159 Relay Sensor 8: Late *CTL [- / - / -] 160 Relay Sensor 8: Lag *CTL [- / - / -] 161 Main Machine Setting Incorrect *CTL [- / - / -] 7520...
  • Page 491 SP7-001 to 931 (Data Log) 001 #PCDU:K 003 #K_Development Unit 004 Development: Bk [0 to 99999999 / 0 / 1/step] 005 Development Filter:K 008 #Cleaning Unit: K 009 K_Cleaning Blade 010 K_Lubricant Brush 011 Lubricant Bar: K [0 to 99999999 / 0 / 1/step] 012 K_Lubricant Blade 013 Brash Drive Joint:K 014 Gears:K...
  • Page 492 5. Main SP Tables-7 037 Gears:C 040 #C_Charge Roller Unit 041 Charge Roller: C [0 to 99999999 / 0 / 1/step] 042 Cleaner:Charge Roller:C 043 Gear:Charge Roller:C 044 #PCU:C 047 #PCDU:M 049 #M_Development Unit 050 Development: M 051 Development Filter:M [0 to 99999999 / 0 / 1/step] 054 #Cleaning Unit: M 055 M_Cleaning Blade...
  • Page 493 SP7-001 to 931 (Data Log) 074 Development Filter:Y 077 #Cleaning Unit: Y 078 Y_Cleaning Blade [0 to 99999999 / 0 / 1/step] 079 Y_Lubricant Brush 080 Lubricant Bar: Y 081 Y_Lubricant Blade 082 Brash Drive Joint:Y 083 Gears:Y [0 to 99999999 / 0 / 1/step] 086 #Y_Charge Roller Unit 087 Charge Roller: Y 088 Cleaner:Charge Roller:Y...
  • Page 494 5. Main SP Tables-7 109 #Paper Transfer Unit 110 Quenching 111 PTR(Paper Transfer Roller) [0 to 99999999 / 0 / 1/step] 114 #Fusing 115 #Fusing Unit 116 Fusing Belt 117 Hot Roller 118 Pressure Roller [0 to 99999999 / 0 / 1/step] 119 Pressure Roller Bearings 126 Web Cleaning Roller 127 Web Roller Stopper...
  • Page 495 SP7-001 to 931 (Data Log) 154 Feed Roller:Tray 2:Separation Roller 157 #Tray3 Roller Assembly 158 Pick-up Roller-Tray3 [0 to 99999999 / 0 / 1/step] 159 Feed Roller:Tray 3:Feeding Roller 160 Feed Roller:Tray 3:Separation Roller 163 #Tray4 Roller Assembly 164 Pick-up Roller-Tray4 165 Feed Roller:Tray 4:Feeding Roller [0 to 99999999 / 0 / 1/step] 166 Feed Roller:Tray 4:Separation Roller...
  • Page 496 5. Main SP Tables-7 187 #Inserter Feed:Tray 1 188 Inserter:Tray1:Pick-up 189 Inserter:Tray1:Feed Belt [0 to 99999999 / 0 / 1/step] 190 Inserter:Tray1:Separate Roller 193 #Inserter Feed:Tray 2 194 Inserter:Tray2:Pick-up 195 Inserter:Tray2:Feed Belt 196 Inserter:Tray2:Separate Roller [0 to 99999999 / 0 / 1/step] 199 #Interposer 200 Feed Belt:Interposer 201 Separation Roller:Interposer...
  • Page 497 SP7-001 to 931 (Data Log) 009 K_Cleaning Blade 010 K_Lubricant Brush 011 Lubricant Bar: K [- / - / -] [Execute] 012 K_Lubricant Blade 013 Brash Drive Joint:K 014 Gears:K 017 #K_Charge Roller Unit 018 Charge Roller: K [- / - / -] 019 Cleaner:Charge Roller:K [Execute] 020 Gear:Charge Roller:K...
  • Page 498 5. Main SP Tables-7 044 #PCU:C 047 #PCDU:M 049 #M_Development Unit 050 Development: M 051 Development Filter:M [- / - / -] [Execute] 054 #Cleaning Unit: M 055 M_Cleaning Blade 056 M_Lubricant Brush 057 Lubricant Bar: M 058 M_Lubricant Blade 059 Brash Drive Joint:M 060 Gears:M [- / - / -]...
  • Page 499 SP7-001 to 931 (Data Log) 081 Y_Lubricant Blade 082 Brash Drive Joint:Y [- / - / -] 083 Gears:Y [Execute] 086 #Y_Charge Roller Unit 087 Charge Roller: Y 088 Cleaner:Charge Roller:Y 089 Gear:Charge Roller:Y [- / - / -] 090 #PCU:Y [Execute] 093 #Image Transfer Unit 094 ITB(Image Transfer Belt)
  • Page 500 5. Main SP Tables-7 116 Fusing Belt 117 Hot Roller [- / - / -] 118 Pressure Roller [Execute] 119 Pressure Roller Bearings 120 Fusing Belt Smoothing Roller 124 #Fusing Cleaning Unit 125 Cleaning Web [- / - / -] 126 Web Cleaning Roller [Execute] 127 Web Roller Stopper...
  • Page 501 SP7-001 to 931 (Data Log) 159 Feed Roller:Tray 3:Feeding Roller 160 Feed Roller:Tray 3:Separation Roller [- / - / -] 163 #Tray4 Roller Assembly [Execute] 164 Pick-up Roller-Tray4 165 Feed Roller:Tray 4:Feeding Roller 166 Feed Roller:Tray 4:Separation Roller 169 #Feed Roller:Bypass [- / - / -] 170 Feed Roller:Bypass:Pick-up [Execute]...
  • Page 502 5. Main SP Tables-7 190 Inserter:Tray1:Separate Roller 193 #Inserter Feed:Tray 2 [- / - / -] 194 Inserter:Tray2:Pick-up [Execute] 195 Inserter:Tray2:Feed Belt 196 Inserter:Tray2:Separate Roller 199 #Interposer 200 Feed Belt:Interposer 201 Separation Roller:Interposer [- / - / -] [Execute] 202 Pick-up Roller:Interposer 205 #ADF 206 ADF Feed Belt 207 ADF Separation Roller...
  • Page 503 SP7-001 to 931 (Data Log) 013 Brash Drive Joint:K 014 Gears:K [0 to 99999999 / 300000 / 1/ 017 #K_Charge Roller Unit step] 018 Charge Roller: K 019 Cleaner:Charge Roller:K 020 Gear:Charge Roller:K [0 to 99999999 / 300000 / 1/ 021 #PCU:K step] 024 #PCDU:C...
  • Page 504 5. Main SP Tables-7 [0 to 99999999 / 3000000 / 1/ 049 #M_Development Unit step] 050 Development: M [0 to 99999999 / 600000 / 1/ step] 051 Development Filter:M 054 #Cleaning Unit: M 055 M_Cleaning Blade [0 to 99999999 / 300000 / 1/ 056 M_Lubricant Brush step] 057 Lubricant Bar: M...
  • Page 505 SP7-001 to 931 (Data Log) 082 Brash Drive Joint:Y 083 Gears:Y [0 to 99999999 / 300000 / 1/ 086 #Y_Charge Roller Unit step] 087 Charge Roller: Y 088 Cleaner:Charge Roller:Y [0 to 99999999 / 300000 / 1/ 089 Gear:Charge Roller:Y step] [0 to 99999999 / 900000 / 1/ 090 #PCU:Y...
  • Page 506 5. Main SP Tables-7 109 #Paper Transfer Unit [0 to 99999999 / 600000 / 1/ 110 Quenching step] 111 PTR(Paper Transfer Roller) [0 to 99999999 / 450000 / 1/ 114 #Fusing step] 115 #Fusing Unit 116 Fusing Belt [0 to 99999999 / 600000 / 1/ 117 Hot Roller step] 118 Pressure Roller...
  • Page 507 SP7-001 to 931 (Data Log) 152 Pick-up Roller-Tray2 153 Feed Roller:Tray 2:Feeding Roller [0 to 99999999 / 1000000 / 1/ 154 Feed Roller:Tray 2:Separation Roller step] 157 #Tray3 Roller Assembly 158 Pick-up Roller-Tray3 159 Feed Roller:Tray 3:Feeding Roller 160 Feed Roller:Tray 3:Separation Roller [0 to 99999999 / 1000000 / 1/ 163 #Tray4 Roller Assembly step]...
  • Page 508 5. Main SP Tables-7 187 #Inserter Feed:Tray 1 188 Inserter:Tray1:Pick-up [0 to 99999999 / 600000 / 1/ 189 Inserter:Tray1:Feed Belt step] 190 Inserter:Tray1:Separate Roller 193 #Inserter Feed:Tray 2 194 Inserter:Tray2:Pick-up 195 Inserter:Tray2:Feed Belt [0 to 99999999 / 600000 / 1/ 196 Inserter:Tray2:Separate Roller step] 199 #Interposer...
  • Page 509 SP7-001 to 931 (Data Log) [0 or 1 / 0 / 1/step] 004 Developer:K *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 005 Developer Filter:K *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 008 #Cleaning Unit:K *CTL 0: No...
  • Page 510 5. Main SP Tables-7 [0 or 1 / 0 / 1/step] 018 Charge Roller:K *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 019 Charge Roller Cleaner:K *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 020 Gear:Charge Roller:K *CTL 0: No...
  • Page 511 SP7-001 to 931 (Data Log) [0 or 1 / 0 / 1/step] 033 Brush Roller:C *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 034 Coating Bar:C *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 035 Apply Blade:C *CTL 0: No...
  • Page 512 5. Main SP Tables-7 [0 or 1 / 0 / 1/step] 047 #PCDU:M *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 049 #Development Unit:M *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 050 Developer:M *CTL 0: No...
  • Page 513 SP7-001 to 931 (Data Log) [0 or 1 / 0 / 1/step] 060 Gear: Cleaning:M *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 063 #Charge Roller Unit:M *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 064 Charge Roller:M *CTL 0: No...
  • Page 514 5. Main SP Tables-7 [0 or 1 / 0 / 1/step] 077 #Cleaning Unit:Y *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 078 Cleaning Blade:Y *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 079 Brush Roller:Y *CTL 0: No...
  • Page 515 SP7-001 to 931 (Data Log) [0 or 1 / 0 / 1/step] 089 Gear: Charge Roller:Y *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 090 #Photo Conduntor:Y *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 093 #ITB Unit *CTL 0: No...
  • Page 516 5. Main SP Tables-7 [0 or 1 / 0 / 1/step] 103 ITB Cleaning Blade *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 104 ITB Lubricant BrushRoller *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 105 ITB Lubricant bar *CTL 0: No...
  • Page 517 SP7-001 to 931 (Data Log) [0 or 1 / 0 / 1/step] 117 Hot Roller *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 118 Pressure Roller *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 119 Shaft Bearing: Press Roller *CTL 0: No...
  • Page 518 5. Main SP Tables-7 [0 or 1 / 0 / 1/step] 132 Dust Filter: Small *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 133 Ozone Filter *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 134 Deodorant Filter: Large *CTL 0: No...
  • Page 519 SP7-001 to 931 (Data Log) [0 or 1 / 0 / 1/step] 152 Pick-up Roller: Tray2 *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 153 Feed Roller: Tray2 *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 154 Separation Roller: Tray2 *CTL 0: No...
  • Page 520 5. Main SP Tables-7 [0 or 1 / 0 / 1/step] 166 Separation Roller: Tray4 *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 169 #By-pass Rollers *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 170 Pick-up Roller: By-pass *CTL 0: No...
  • Page 521 SP7-001 to 931 (Data Log) [0 or 1 / 0 / 1/step] 182 Pick-up Roller: A4_LT LCT *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 183 Feed Roller: A4_LT LCT *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 184 Separation Roller: A4_LT LCT *CTL 0: No...
  • Page 522 5. Main SP Tables-7 [0 or 1 / 0 / 1/step] 196 Separation Roller: Inserter Tray2 *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 199 #Interposer *CTL 0: No 1: Yes [0 or 1 / 0 / 1/step] 200 Feed Belt: Interposer *CTL 0: No...
  • Page 523 SP7-001 to 931 (Data Log) 001 #PCDU:K 003 #K_Development Unit 004 Development: Bk [0 to 99999999 / 0 / 1/step] 005 Development Filter:K 008 #Cleaning Unit: K 009 K_Cleaning Blade 010 K_Lubricant Brush 011 Lubricant Bar: K [0 to 99999999 / 0 / 1/step] 012 K_Lubricant Blade 013 Brash Drive Joint:K 014 Gears:K...
  • Page 524 5. Main SP Tables-7 036 Brash Drive Joint:C 037 Gears:C 040 #C_Charge Roller Unit [0 to 99999999 / 0 / 1/step] 041 Charge Roller: C 042 Cleaner:Charge Roller:C 043 Gear:Charge Roller:C 044 #PCU:C 047 #PCDU:M [0 to 99999999 / 0 / 1/step] 049 #M_Development Unit 050 Development: M 051 Development Filter:M...
  • Page 525 SP7-001 to 931 (Data Log) 074 Development Filter:Y 077 #Cleaning Unit: Y 078 Y_Cleaning Blade [0 to 99999999 / 0 / 1/step] 079 Y_Lubricant Brush 080 Lubricant Bar: Y 081 Y_Lubricant Blade 082 Brash Drive Joint:Y 083 Gears:Y [0 to 99999999 / 0 / 1/step] 086 #Y_Charge Roller Unit 087 Charge Roller: Y 088 Cleaner:Charge Roller:Y...
  • Page 526 5. Main SP Tables-7 109 #Paper Transfer Unit 110 Quenching 111 PTR(Paper Transfer Roller) [0 to 99999999 / 0 / 1/step] 114 #Fusing 115 #Fusing Unit 116 Fusing Belt 117 Hot Roller 118 Pressure Roller [0 to 99999999 / 0 / 1/step] 119 Pressure Roller Bearings 126 Web Cleaning Roller 127 Web Roller Stopper...
  • Page 527 SP7-001 to 931 (Data Log) 157 #Tray3 Roller Assembly 158 Pick-up Roller-Tray3 159 Feed Roller:Tray 3:Feeding Roller [0 to 99999999 / 0 / 1/step] 160 Feed Roller:Tray 3:Separation Roller 163 #Tray4 Roller Assembly 164 Pick-up Roller-Tray4 165 Feed Roller:Tray 4:Feeding Roller 166 Feed Roller:Tray 4:Separation Roller [0 to 99999999 / 0 / 1/step] 169 #Feed Roller:Bypass...
  • Page 528 5. Main SP Tables-7 194 Inserter:Tray2:Pick-up 195 Inserter:Tray2:Feed Belt 196 Inserter:Tray2:Separate Roller [0 to 99999999 / 0 / 1/step] 199 #Interposer 200 Feed Belt:Interposer 201 Separation Roller:Interposer 202 Pick-up Roller:Interposer 205 #ADF [0 to 99999999 / 0 / 1/step] 206 ADF Feed Belt 207 ADF Separation Roller 208 ADF Pick-up Roller [0 to 99999999 / 0 / 1/step]...
  • Page 529 SP7-001 to 931 (Data Log) 014 Gears:K 017 #K_Charge Roller Unit 018 Charge Roller: K [0 to 99999999 / 0 / 1/step] 019 Cleaner:Charge Roller:K 020 Gear:Charge Roller:K 021 #PCU:K 024 #PCDU:C 026 #C_Development Unit [0 to 99999999 / 0 / 1/step] 027 Development: C 028 Development Filter:C 031 #Cleaning Unit: C...
  • Page 530 5. Main SP Tables-7 054 #Cleaning Unit: M 055 M_Cleaning Blade 056 M_Lubricant Brush [0 to 99999999 / 0 / 1/step] 057 Lubricant Bar: M 058 M_Lubricant Blade 059 Brash Drive Joint:M 060 Gears:M 063 #M_Charge Roller Unit [0 to 99999999 / 0 / 1/step] 064 Charge Roller: M 065 Cleaner:Charge Roller:M 066 Gear:Charge Roller:M...
  • Page 531 SP7-001 to 931 (Data Log) 088 Cleaner:Charge Roller:Y 089 Gear:Charge Roller:Y 090 #PCU:Y [0 to 99999999 / 0 / 1/step] 093 #Image Transfer Unit 094 ITB(Image Transfer Belt) 095 ITB Roller: K 096 ITB Roller: C 097 ITB Roller: M [0 to 99999999 / 0 / 1/step] 098 ITB Roller: Y 099 ITB Bias Roller...
  • Page 532 5. Main SP Tables-7 127 Web Roller Stopper 130 #Main Unit Filters 131 Dust Filter:Large [0 to 99999999 / 0 / 1/step] 132 Dust Filter:Small 133 Ozone Filter 134 Deodorant Filter:Large 135 Deodorant Filter:Small 145 #Tray1 Roller Assembly [0 to 99999999 / 0 / 1/step] 146 Pick-up Roller-Tray1 147 Feed Roller:Tray 1:Feeding Roller 148 Feed Roller:Tray 1:Separation Roller...
  • Page 533 SP7-001 to 931 (Data Log) 171 Feed Roller:Bypass:Feeding Roller Feed Roller:Bypass:Separation Roller [0 to 99999999 / 0 / 1/step] 175 #Feed Roller:A3LCT 176 Feed Roller:A3LCT:Pick-up 177 Feed Roller:A3LCT:Feeding Roller 178 Feed Roller:A3LCT:Separation Roller 181 #Feed Roller:A4LCT 182 Feed Roller:A4LCT:Pick-up [0 to 99999999 / 0 / 1/step] 183 Feed Roller:A4LCT:Feeding Roller 184 Feed Roller:A4LCT:Separation Roller 187 #Inserter Feed:Tray 1...
  • Page 534 5. Main SP Tables-7 208 ADF Pick-up Roller [0 to 99999999 / 0 / 1/step] [Reset] 7628 Resets all counts for PM Counter. [- / - / -] 002 Reset All Counts [Execute] [ROM No./ Firmware Version] 7801 Displays all version numbers, part numbers in machine. 255 - [PM Counter Display] 7803...
  • Page 535 SP7-001 to 931 (Data Log) [MF Error Counter] 7826 Displays the counter that couldn’t send count command to the MF charging device. 001 Error Total *CTL [- / - / -] 002 Error Staple *CTL [- / - / -] [MF Error Counter Clear] 7827 Clears MF Error Counter.
  • Page 536 5. Main SP Tables-7 002 Change Time : Last1 *CTL [- / - / -] 101 Initialize Time : Latest *CTL [- / - / -] 102 Initialize Time : Last1 *CTL [- / - / -] 7852 [DF Glass Dust Check] Dust Detection Counter *ENG [0 to 65535 / 0 / 1/step]...
  • Page 537 SP7-001 to 931 (Data Log) [ROM Number] 7910 005 ADF [- / - / -] 007 Finisher 1 [- / - / -] 008 Finisher 2 [- / - / -] 010 LCT [- / - / -] 011 Mailbox [- / - / -] 020 Inserter [- / - / -]...
  • Page 538 5. Main SP Tables-7 010 LCT [- / - / -] 011 Mailbox [- / - / -] 020 Inserter [- / - / -] 025 Z-Fold [- / - / -] 026 IH Fusing [- / - / -] 029 R-Binder (Basement 1) [- / - / -] 030 Ri-Binder (Basement 2)
  • Page 539 SP7-001 to 931 (Data Log) 008 New Product Information *ENG [0 to 255 / 0 / 1/step] 009 Recycle Counter *ENG [0 to 255 / 0 / 1/step] Date *ENG [0 or 1 / 0 / 1/step] Uses for Toner Individual Detection. SerialNo.
  • Page 540 5. Main SP Tables-7 End Date *ENG [0 or 1 / 0 / 1/step] Writes Date for Toner End. Writes also when Near End is detected.
  • Page 541: Sp7-932 To 988 (Data Log)

    SP7-932 to 988 (Data Log) SP7-932 to 988 (Data Log) 7932 [Toner Bottle C] Machine Serial ID *ENG [0 to 255 / 0 / 1/step] Machine Serial Code used in Machine Serial Code API. 002 Cartridge Ver *ENG [0 to 255 / 0 / 1/step] 003 Brand ID *ENG [0 to 255 / 0 / 1/step]...
  • Page 542 5. Main SP Tables-7 Attachment: Total Counter *ENG [0 to 99999999 / 0 / 1/step] Writes Main Unit Total Counter Value with binary data when Toner is attached. Attachment: Color Counter *ENG [0 to 99999999 / 0 / 1/step] Writes Main Unit Color Counter Value with binary data when Toner is attached. End: Total Counter *ENG [0 to 99999999 / 0 / 1/step]...
  • Page 543 SP7-932 to 988 (Data Log) Date *ENG [0 or 1 / 0 / 1/step] Uses for Toner Individual Detection. SerialNo. *ENG [0 or 1 / 0 / 1/step] Uses for Toner Individual Detection. Toner Remaining *ENG [0 to 100 / 100 / 1%/step] Keeps the data with 1% Step.
  • Page 544 5. Main SP Tables-7 7934 [Toner Bottle Y] Machine Serial ID *ENG [0 to 255 / 0 / 1/step] Machine Serial Code used in Machine Serial Code API. 002 Machine Serial ID *ENG [0 to 255 / 0 / 1/step] 003 Cartridge Ver *ENG [0 to 255 / 0 / 1/step]...
  • Page 545 SP7-932 to 988 (Data Log) Attachment: Color Counter *ENG [0 to 99999999 / 0 / 1/step] Writes Main Unit Color Counter Value with binary data when Toner is attached. End: Total Counter *ENG [0 to 99999999 / 0 / 1/step] Writes Main Unit Total Counter Value with binary data when End is detected.
  • Page 546 5. Main SP Tables-7 Attachment: Total Counter *ENG [0 to 999999 / 0 / 1/step] Writes Main Unit Total Counter Value with binary data when Toner is attached. Refill Information *ENG [0 or 1 / 0 / 1/step] Refill Detection, IS Detection Information 7935 [Toner Bottle Log 3: Bk] SerialNo.
  • Page 547 SP7-932 to 988 (Data Log) Attachment Date *ENG [0 or 1 / 0 / 1/step] Writes Date when Toner is attached. Attachment: Total Counter *ENG [0 to 999999 / 0 / 1/step] Writes Main Unit Total Counter Value with binary data when Toner is attached. Refill Information *ENG [0 or 1 / 0 / 1/step]...
  • Page 548 5. Main SP Tables-7 SerialNo. *ENG [0 or 1 / 0 / 1/step] Displays traditional ASCII 16 byte Display with BCD 8byte. Attachment Date *ENG [0 or 1 / 0 / 1/step] Writes Date when Toner is attached. Attachment: Total Counter *ENG [0 to 999999 / 0 / 1/step] Writes Main Unit Total Counter Value with binary data when Toner is attached.
  • Page 549 SP7-932 to 988 (Data Log) 7937 [Toner Bottle Log 1:C] SerialNo. *ENG [0 or 1 / 0 / 1/step] Displays traditional ASCII 16 byte Display with BCD 8byte. Attachment Date *ENG [0 or 1 / 0 / 1/step] Writes Date when Toner is attached. Attachment: Total Counter *ENG [0 to 999999 / 0 / 1/step]...
  • Page 550 5. Main SP Tables-7 Refill Information *ENG [0 or 1 / 0 / 1/step] Refill Detection, IS Detection Information 7937 [Toner Bottle Log 4:C] SerialNo. *ENG [0 or 1 / 0 / 1/step] Displays traditional ASCII 16 byte Display with BCD 8byte. Attachment Date *ENG [0 or 1 / 0 / 1/step]...
  • Page 551 SP7-932 to 988 (Data Log) Attachment: Total Counter *ENG [0 to 999999 / 0 / 1/step] Writes Main Unit Total Counter Value with binary data when Toner is attached. Refill Information *ENG [0 or 1 / 0 / 1/step] Refill Detection, IS Detection Information 7938 [Toner Bottle Log 2: Y] SerialNo.
  • Page 552 5. Main SP Tables-7 Attachment Date *ENG [0 or 1 / 0 / 1/step] Writes Date when Toner is attached. Attachment: Total Counter *ENG [0 to 999999 / 0 / 1/step] Writes Main Unit Total Counter Value with binary data when Toner is attached. Refill Information *ENG [0 or 1 / 0 / 1/step]...
  • Page 553 SP7-932 to 988 (Data Log) 011 Lubricant Bar: K [0 to 999999 / 167500 / 1m/step] 012 K_Lubricant Blade [0 to 999999 / 167500 / 1m/step] 013 Brash Drive Joint:K [0 to 999999 / 167500 / 1m/step] 014 Gears:K [0 to 999999 / 167500 / 1m/step] 017 #K_Charge Roller Unit [0 to 999999 / 167500 / 1m/step] 018 Charge Roller: K...
  • Page 554 5. Main SP Tables-7 047 #PCDU:M [0 to 999999 / 167500 / 1m/step] [0 to 999999 / 1289500 / 1m/ 049 #M_Development Unit step] 050 Development: M [0 to 999999 / 257900 / 1m/step] 051 Development Filter:M [0 to 999999 / 257900 / 1m/step] 054 #Cleaning Unit: M [0 to 999999 / 167500 / 1m/step] 055 M_Cleaning Blade...
  • Page 555 SP7-932 to 988 (Data Log) 081 Y_Lubricant Blade [0 to 999999 / 167500 / 1m/step] 082 Brash Drive Joint:Y [0 to 999999 / 167500 / 1m/step] 083 Gears:Y [0 to 999999 / 167500 / 1m/step] 086 #Y_Charge Roller Unit [0 to 999999 / 167500 / 1m/step] 087 Charge Roller: Y [0 to 999999 / 167500 / 1m/step] 088 Cleaner:Charge Roller:Y...
  • Page 556 5. Main SP Tables-7 [0 to 999999 / 99999999 / 1m/ 115 #Fusing Unit step] [0 to 999999 / 99999999 / 1m/ 116 Fusing Belt step] [0 to 999999 / 99999999 / 1m/ 117 Hot Roller step] [0 to 999999 / 99999999 / 1m/ 118 Pressure Roller step] [0 to 999999 / 99999999 / 1m/...
  • Page 557 SP7-932 to 988 (Data Log) 014 Gears:K 017 #K_Charge Roller Unit 018 Charge Roller: K [0 to 255 / 0 / 1%/step] 019 Cleaner:Charge Roller:K 020 Gear:Charge Roller:K 021 #PCU:K 024 #PCDU:C 026 #C_Development Unit [0 to 255 / 0 / 1%/step] 027 Development: C 028 Development Filter:C 031 #Cleaning Unit: C...
  • Page 558 5. Main SP Tables-7 051 Development Filter:M 054 #Cleaning Unit: M 055 M_Cleaning Blade [0 to 255 / 0 / 1%/step] 056 M_Lubricant Brush 057 Lubricant Bar: M 058 M_Lubricant Blade 059 Brash Drive Joint:M 060 Gears:M [0 to 255 / 0 / 1%/step] 063 #M_Charge Roller Unit 064 Charge Roller: M 065 Cleaner:Charge Roller:M...
  • Page 559 SP7-932 to 988 (Data Log) 087 Charge Roller: Y 088 Cleaner:Charge Roller:Y 089 Gear:Charge Roller:Y [0 to 255 / 0 / 1%/step] 090 #PCU:Y 093 #Image Transfer Unit 094 ITB(Image Transfer Belt) 095 ITB Roller: K 096 ITB Roller: C [0 to 255 / 0 / 1%/step] 097 ITB Roller: M 098 ITB Roller: Y...
  • Page 560 5. Main SP Tables-7 120 Fusing Belt Smoothing Roller 124 #Fusing Cleaning Unit 125 Cleaning Web [0 to 255 / 0 / 1%/step] 126 Web Cleaning Roller 127 Web Roller Stopper [Motor Drv Distance Counter] 7944 Displays Motor Drive Distance Counter. 001 #PCDU:K 003 #K_Development Unit 004 Development: Bk...
  • Page 561 SP7-932 to 988 (Data Log) 021 #PCU:K 024 #PCDU:C 026 #C_Development Unit [0 to 999999 / 0 / 1m/step] 027 Development: C 028 Development Filter:C 031 #Cleaning Unit: C 032 C_Cleaning Blade 033 C_Lubricant Brush [0 to 999999 / 0 / 1m/step] 034 Lubricant Bar: C 035 C_Lubricant Blade 036 Brash Drive Joint:C...
  • Page 562 5. Main SP Tables-7 058 M_Lubricant Blade 059 Brash Drive Joint:M 060 Gears:M [0 to 999999 / 0 / 1m/step] 063 #M_Charge Roller Unit 064 Charge Roller: M 065 Cleaner:Charge Roller:M 066 Gear:Charge Roller:M 067 #PCU:M [0 to 999999 / 0 / 1m/step] 070 #PCDU:Y 072 #Y_Development Unit 073 Development: Y...
  • Page 563 SP7-932 to 988 (Data Log) 094 ITB(Image Transfer Belt) 095 ITB Roller: K 096 ITB Roller: C [0 to 999999 / 0 / 1m/step] 097 ITB Roller: M 098 ITB Roller: Y 099 ITB Bias Roller 102 #ITB Cleaning Unit 103 ITB Cleaning Blade [0 to 999999 / 0 / 1m/step] 104 Lubricant Brush...
  • Page 564 5. Main SP Tables-7 001 #PCDU:K 003 #K_Development Unit 004 Development: Bk [0 or 1 / 0 / 1/step] 005 Development Filter:K 008 #Cleaning Unit: K 009 K_Cleaning Blade 010 K_Lubricant Brush 011 Lubricant Bar: K [0 or 1 / 0 / 1/step] 012 K_Lubricant Blade 013 Brash Drive Joint:K 014 Gears:K...
  • Page 565 SP7-932 to 988 (Data Log) 036 Brash Drive Joint:C 037 Gears:C 040 #C_Charge Roller Unit [0 or 1 / 0 / 1/step] 041 Charge Roller: C 042 Cleaner:Charge Roller:C 043 Gear:Charge Roller:C 044 #PCU:C 047 #PCDU:M [0 or 1 / 0 / 1/step] 049 #M_Development Unit 050 Development: M 051 Development Filter:M...
  • Page 566 5. Main SP Tables-7 073 Development: Y 074 Development Filter:Y 077 #Cleaning Unit: Y [0 or 1 / 0 / 1/step] 078 Y_Cleaning Blade 079 Y_Lubricant Brush 080 Lubricant Bar: Y 081 Y_Lubricant Blade 082 Brash Drive Joint:Y [0 or 1 / 0 / 1/step] 083 Gears:Y 086 #Y_Charge Roller Unit 087 Charge Roller: Y...
  • Page 567 SP7-932 to 988 (Data Log) 106 Lube Application Blade 109 #Paper Transfer Unit 110 Quenching [0 or 1 / 0 / 1/step] 111 PTR(Paper Transfer Roller) 114 #Fusing 115 #Fusing Unit 116 Fusing Belt 117 Hot Roller [0 or 1 / 0 / 1/step] 118 Pressure Roller 119 Pressure Roller Bearings 126 Web Cleaning Roller...
  • Page 568 5. Main SP Tables-7 153 Feed Roller:Tray 2:Feeding Roller 154 Feed Roller:Tray 2:Separation Roller 157 #Tray3 Roller Assembly [0 or 1 / 0 / 1/step] 158 Pick-up Roller-Tray3 159 Feed Roller:Tray 3:Feeding Roller 160 Feed Roller:Tray 3:Separation Roller 163 #Tray4 Roller Assembly 164 Pick-up Roller-Tray4 [0 or 1 / 0 / 1/step] 165 Feed Roller:Tray 4:Feeding Roller...
  • Page 569 SP7-932 to 988 (Data Log) 190 Inserter:Tray1:Separate Roller 193 #Inserter Feed:Tray 2 194 Inserter:Tray2:Pick-up [0 or 1 / 0 / 1/step] 195 Inserter:Tray2:Feed Belt 196 Inserter:Tray2:Separate Roller 199 #Interposer 200 Feed Belt:Interposer 201 Separation Roller:Interposer [0 or 1 / 0 / 1/step] 202 Pick-up Roller:Interposer 205 #ADF 206 ADF Feed Belt...
  • Page 570 5. Main SP Tables-7 014 Gears:K 017 #K_Charge Roller Unit 018 Charge Roller: K [0 to 255 / 255 / 1day/step] 019 Cleaner:Charge Roller:K 020 Gear:Charge Roller:K 021 #PCU:K 024 #PCDU:C 026 #C_Development Unit [0 to 255 / 255 / 1day/step] 027 Development: C 028 Development Filter:C 031 #Cleaning Unit: C...
  • Page 571 SP7-932 to 988 (Data Log) 051 Development Filter:M 054 #Cleaning Unit: M 055 M_Cleaning Blade [0 to 255 / 255 / 1day/step] 056 M_Lubricant Brush 057 Lubricant Bar: M 058 M_Lubricant Blade 059 Brash Drive Joint:M 060 Gears:M [0 to 255 / 255 / 1day/step] 063 #M_Charge Roller Unit 064 Charge Roller: M 065 Cleaner:Charge Roller:M...
  • Page 572 5. Main SP Tables-7 087 Charge Roller: Y 088 Cleaner:Charge Roller:Y 089 Gear:Charge Roller:Y [0 to 255 / 255 / 1day/step] 090 #PCU:Y 093 #Image Transfer Unit 094 ITB(Image Transfer Belt) 095 ITB Roller: K 096 ITB Roller: C [0 to 255 / 255 / 1day/step] 097 ITB Roller: M 098 ITB Roller: Y 099 ITB Bias Roller...
  • Page 573 SP7-932 to 988 (Data Log) 126 Web Cleaning Roller 127 Web Roller Stopper 130 #Main Unit Filters [0 to 255 / 255 / 1day/step] 131 Dust Filter:Large 132 Dust Filter:Small 133 Ozone Filter 134 Deodorant Filter:Large 135 Deodorant Filter:Small [0 to 255 / 255 / 1day/step] 142 Waste Toner Bottle 145 #Tray1 Roller Assembly 146 Pick-up Roller-Tray1...
  • Page 574 5. Main SP Tables-7 169 #Feed Roller:Bypass 170 Feed Roller:Bypass:Pick-up 171 Feed Roller:Bypass:Feeding Roller [0 to 255 / 255 / 1day/step] Feed Roller:Bypass:Separation Roller 175 #Feed Roller:A3LCT 176 Feed Roller:A3LCT:Pick-up 177 Feed Roller:A3LCT:Feeding Roller 178 Feed Roller:A3LCT:Separation Roller [0 to 255 / 255 / 1day/step] 181 #Feed Roller:A4LCT 182 Feed Roller:A4LCT:Pick-up 183 Feed Roller:A4LCT:Feeding Roller...
  • Page 575 SP7-932 to 988 (Data Log) 206 ADF Feed Belt 207 ADF Separation Roller [0 to 255 / 255 / 1day/step] 208 ADF Pick-up Roller [Remain Day Counter: Distance] 7952 Displays the remaining operable days calculated from Distance Remain Day Counter. 001 #PCDU:K 003 #K_Development Unit 004 Development: Bk...
  • Page 576 5. Main SP Tables-7 031 #Cleaning Unit: C 032 C_Cleaning Blade 033 C_Lubricant Brush [0 to 255 / 255 / 1day/step] 034 Lubricant Bar: C 035 C_Lubricant Blade 036 Brash Drive Joint:C 037 Gears:C 040 #C_Charge Roller Unit [0 to 255 / 255 / 1day/step] 041 Charge Roller: C 042 Cleaner:Charge Roller:C 043 Gear:Charge Roller:C...
  • Page 577 SP7-932 to 988 (Data Log) 065 Cleaner:Charge Roller:M 066 Gear:Charge Roller:M 067 #PCU:M [0 to 255 / 255 / 1day/step] 070 #PCDU:Y 072 #Y_Development Unit 073 Development: Y 074 Development Filter:Y 077 #Cleaning Unit: Y [0 to 255 / 255 / 1day/step] 078 Y_Cleaning Blade 079 Y_Lubricant Brush 080 Lubricant Bar: Y...
  • Page 578 5. Main SP Tables-7 099 ITB Bias Roller 102 #ITB Cleaning Unit 103 ITB Cleaning Blade [0 to 255 / 255 / 1day/step] 104 Lubricant Brush 105 Lubrication: Belt Cleanig 106 Lube Application Blade 109 #Paper Transfer Unit 110 Quenching [0 to 255 / 255 / 1day/step] 111 PTR(Paper Transfer Roller) 114 #Fusing...
  • Page 579 SP7-932 to 988 (Data Log) 009 K_Cleaning Blade 010 K_Lubricant Brush 011 Lubricant Bar: K [0 to 255 / 255 / 1/step] 012 K_Lubricant Blade 013 Brash Drive Joint:K 014 Gears:K 017 #K_Charge Roller Unit 018 Charge Roller: K [0 to 255 / 255 / 1/step] 019 Cleaner:Charge Roller:K 020 Gear:Charge Roller:K 021 #PCU:K...
  • Page 580 5. Main SP Tables-7 043 Gear:Charge Roller:C 044 #PCU:C 047 #PCDU:M [0 to 255 / 255 / 1/step] 049 #M_Development Unit 050 Development: M 051 Development Filter:M 054 #Cleaning Unit: M 055 M_Cleaning Blade [0 to 255 / 255 / 1/step] 056 M_Lubricant Brush 057 Lubricant Bar: M 058 M_Lubricant Blade...
  • Page 581 SP7-932 to 988 (Data Log) 080 Lubricant Bar: Y 081 Y_Lubricant Blade 082 Brash Drive Joint:Y [0 to 255 / 255 / 1/step] 083 Gears:Y 086 #Y_Charge Roller Unit 087 Charge Roller: Y 088 Cleaner:Charge Roller:Y 089 Gear:Charge Roller:Y [0 to 255 / 255 / 1/step] 090 #PCU:Y 093 #Image Transfer Unit 094 ITB(Image Transfer Belt)
  • Page 582 5. Main SP Tables-7 115 #Fusing Unit 116 Fusing Belt 117 Hot Roller [0 to 255 / 255 / 1/step] 118 Pressure Roller 119 Pressure Roller Bearings 126 Web Cleaning Roller 127 Web Roller Stopper 130 #Main Unit Filters [0 to 255 / 255 / 1/step] 131 Dust Filter:Large 132 Dust Filter:Small 133 Ozone Filter...
  • Page 583 SP7-932 to 988 (Data Log) 160 Feed Roller:Tray 3:Separation Roller 163 #Tray4 Roller Assembly 164 Pick-up Roller-Tray4 [0 to 255 / 255 / 1/step] 165 Feed Roller:Tray 4:Feeding Roller 166 Feed Roller:Tray 4:Separation Roller 169 #Feed Roller:Bypass 170 Feed Roller:Bypass:Pick-up 171 Feed Roller:Bypass:Feeding Roller [0 to 255 / 255 / 1/step] Feed Roller:Bypass:Separation...
  • Page 584 5. Main SP Tables-7 199 #Interposer 200 Feed Belt:Interposer 201 Separation Roller:Interposer [0 to 255 / 255 / 1/step] 202 Pick-up Roller:Interposer 205 #ADF 206 ADF Feed Belt 207 ADF Separation Roller [0 to 255 / 255 / 1/step] 208 ADF Pick-up Roller [Estimated Remain Pages] 7955 Displays the estimated remaining operable pages calculated from Pages Remain Day...
  • Page 585 SP7-932 to 988 (Data Log) 014 Gears:K 017 #K_Charge Roller Unit 018 Charge Roller: K [0 to 99999999 / 0 / 1sheet/step] 019 Cleaner:Charge Roller:K 020 Gear:Charge Roller:K 021 #PCU:K 024 #PCDU:C 026 #C_Development Unit [0 to 99999999 / 0 / 1sheet/step] 027 Development: C 028 Development Filter:C 031 #Cleaning Unit: C...
  • Page 586 5. Main SP Tables-7 051 Development Filter:M 054 #Cleaning Unit: M 055 M_Cleaning Blade [0 to 99999999 / 0 / 1sheet/step] 056 M_Lubricant Brush 057 Lubricant Bar: M 058 M_Lubricant Blade 059 Brash Drive Joint:M 060 Gears:M [0 to 99999999 / 0 / 1sheet/step] 063 #M_Charge Roller Unit 064 Charge Roller: M 065 Cleaner:Charge Roller:M...
  • Page 587 SP7-932 to 988 (Data Log) 087 Charge Roller: Y 088 Cleaner:Charge Roller:Y 089 Gear:Charge Roller:Y [0 to 99999999 / 0 / 1sheet/step] 090 #PCU:Y 093 #Image Transfer Unit 094 ITB(Image Transfer Belt) 095 ITB Roller: K 096 ITB Roller: C [0 to 99999999 / 0 / 1sheet/step] 097 ITB Roller: M 098 ITB Roller: Y...
  • Page 588 5. Main SP Tables-7 126 Web Cleaning Roller 127 Web Roller Stopper 130 #Main Unit Filters [0 to 99999999 / 0 / 1sheet/step] 131 Dust Filter:Large 132 Dust Filter:Small 133 Ozone Filter 134 Deodorant Filter:Large 135 Deodorant Filter:Small [0 to 99999999 / 0 / 1sheet/step] 145 #Tray1 Roller Assembly 146 Pick-up Roller-Tray1 147 Feed Roller:Tray 1:Feeding Roller...
  • Page 589 SP7-932 to 988 (Data Log) 170 Feed Roller:Bypass:Pick-up 171 Feed Roller:Bypass:Feeding Roller Feed Roller:Bypass:Separation [0 to 99999999 / 0 / 1sheet/step] Roller 175 #Feed Roller:A3LCT 176 Feed Roller:A3LCT:Pick-up 177 Feed Roller:A3LCT:Feeding Roller 178 Feed Roller:A3LCT:Separation Roller 181 #Feed Roller:A4LCT [0 to 99999999 / 0 / 1sheet/step] 182 Feed Roller:A4LCT:Pick-up 183 Feed Roller:A4LCT:Feeding Roller 184 Feed Roller:A4LCT:Separation Roller...
  • Page 590 5. Main SP Tables-7 207 ADF Separation Roller [0 to 99999999 / 0 / 1sheet/step] 208 ADF Pick-up Roller [Estimated Remain Days] 7956 Displays the estimated remaining operable days calculated from Pages Remain Day Counter and Distance Remain Day Counter. 001 #PCDU:K 003 #K_Development Unit 004 Development: Bk...
  • Page 591 SP7-932 to 988 (Data Log) 031 #Cleaning Unit: C 032 C_Cleaning Blade 033 C_Lubricant Brush [0 to 255 / 255 / 1day/step] 034 Lubricant Bar: C 035 C_Lubricant Blade 036 Brash Drive Joint:C 037 Gears:C 040 #C_Charge Roller Unit [0 to 255 / 255 / 1day/step] 041 Charge Roller: C 042 Cleaner:Charge Roller:C 043 Gear:Charge Roller:C...
  • Page 592 5. Main SP Tables-7 065 Cleaner:Charge Roller:M 066 Gear:Charge Roller:M 067 #PCU:M [0 to 255 / 255 / 1day/step] 070 #PCDU:Y 072 #Y_Development Unit 073 Development: Y 074 Development Filter:Y 077 #Cleaning Unit: Y [0 to 255 / 255 / 1day/step] 078 Y_Cleaning Blade 079 Y_Lubricant Brush 080 Lubricant Bar: Y...
  • Page 593 SP7-932 to 988 (Data Log) 099 ITB Bias Roller 102 #ITB Cleaning Unit 103 ITB Cleaning Blade [0 to 255 / 255 / 1day/step] 104 Lubricant Brush 105 Lubrication: Belt Cleanig 106 Lube Application Blade 109 #Paper Transfer Unit 110 Quenching [0 to 255 / 255 / 1day/step] 111 PTR(Paper Transfer Roller) 114 #Fusing...
  • Page 594 5. Main SP Tables-7 146 Pick-up Roller-Tray1 147 Feed Roller:Tray 1:Feeding Roller 148 Feed Roller:Tray 1:Separation Roller [0 to 255 / 255 / 1day/step] 151 #Tray2 Roller Assembly 152 Pick-up Roller-Tray2 153 Feed Roller:Tray 2:Feeding Roller 154 Feed Roller:Tray 2:Separation Roller 157 #Tray3 Roller Assembly [0 to 255 / 255 / 1day/step] 158 Pick-up Roller-Tray3...
  • Page 595 SP7-932 to 988 (Data Log) 183 Feed Roller:A4LCT:Feeding Roller 184 Feed Roller:A4LCT:Separation Roller 187 #Inserter Feed:Tray 1 [0 to 255 / 255 / 1day/step] 188 Inserter:Tray1:Pick-up 189 Inserter:Tray1:Feed Belt 190 Inserter:Tray1:Separate Roller 193 #Inserter Feed:Tray 2 194 Inserter:Tray2:Pick-up [0 to 255 / 255 / 1day/step] 195 Inserter:Tray2:Feed Belt 196 Inserter:Tray2:Separate Roller 199 #Interposer...
  • Page 596 5. Main SP Tables-7 009 K_Cleaning Blade 010 K_Lubricant Brush 011 Lubricant Bar: K [0 to 99999999 / 0 / 1sheet/step] 012 K_Lubricant Blade 013 Brash Drive Joint:K 014 Gears:K 017 #K_Charge Roller Unit 018 Charge Roller: K [0 to 99999999 / 0 / 1sheet/step] 019 Cleaner:Charge Roller:K 020 Gear:Charge Roller:K 021 #PCU:K...
  • Page 597 SP7-932 to 988 (Data Log) 043 Gear:Charge Roller:C 044 #PCU:C 047 #PCDU:M [0 to 99999999 / 0 / 1sheet/step] 049 #M_Development Unit 050 Development: M 051 Development Filter:M 054 #Cleaning Unit: M 055 M_Cleaning Blade [0 to 99999999 / 0 / 1sheet/step] 056 M_Lubricant Brush 057 Lubricant Bar: M 058 M_Lubricant Blade...
  • Page 598 5. Main SP Tables-7 080 Lubricant Bar: Y 081 Y_Lubricant Blade 082 Brash Drive Joint:Y [0 to 99999999 / 0 / 1sheet/step] 083 Gears:Y 086 #Y_Charge Roller Unit 087 Charge Roller: Y 088 Cleaner:Charge Roller:Y 089 Gear:Charge Roller:Y [0 to 99999999 / 0 / 1sheet/step] 090 #PCU:Y 093 #Image Transfer Unit 094 ITB(Image Transfer Belt)
  • Page 599 SP7-932 to 988 (Data Log) 115 #Fusing Unit 116 Fusing Belt 117 Hot Roller [0 to 99999999 / 0 / 1sheet/step] 118 Pressure Roller 119 Pressure Roller Bearings 126 Web Cleaning Roller 127 Web Roller Stopper 130 #Main Unit Filters [0 to 99999999 / 0 / 1sheet/step] 131 Dust Filter:Large 132 Dust Filter:Small...
  • Page 600 5. Main SP Tables-7 163 #Tray4 Roller Assembly 164 Pick-up Roller-Tray4 165 Feed Roller:Tray 4:Feeding Roller [0 to 99999999 / 0 / 1sheet/step] 166 Feed Roller:Tray 4:Separation Roller 169 #Feed Roller:Bypass 170 Feed Roller:Bypass:Pick-up 171 Feed Roller:Bypass:Feeding Roller Feed Roller:Bypass:Separation [0 to 99999999 / 0 / 1sheet/step] Roller 175 #Feed Roller:A3LCT...
  • Page 601 SP7-932 to 988 (Data Log) 200 Feed Belt:Interposer 201 Separation Roller:Interposer 202 Pick-up Roller:Interposer [0 to 99999999 / 0 / 1sheet/step] 205 #ADF 206 ADF Feed Belt 207 ADF Separation Roller [0 to 99999999 / 0 / 1sheet/step] 208 ADF Pick-up Roller [PM Value Setting:DaysThreshold] 7958 Sets Days Threshold for Waste Toner Bottle @Remote Automatic Ordering.
  • Page 602 5. Main SP Tables-7 014 Gears:K 017 #K_Charge Roller Unit 018 Charge Roller: K [0 to 255 / 0 / 1/step] 019 Cleaner:Charge Roller:K 020 Gear:Charge Roller:K 021 #PCU:K 024 #PCDU:C 026 #C_Development Unit [0 to 255 / 0 / 1/step] 027 Development: C 028 Development Filter:C 031 #Cleaning Unit: C...
  • Page 603 SP7-932 to 988 (Data Log) 051 Development Filter:M 054 #Cleaning Unit: M 055 M_Cleaning Blade [0 to 255 / 0 / 1/step] 056 M_Lubricant Brush 057 Lubricant Bar: M 058 M_Lubricant Blade 059 Brash Drive Joint:M 060 Gears:M [0 to 255 / 0 / 1/step] 063 #M_Charge Roller Unit 064 Charge Roller: M 065 Cleaner:Charge Roller:M...
  • Page 604 5. Main SP Tables-7 087 Charge Roller: Y 088 Cleaner:Charge Roller:Y 089 Gear:Charge Roller:Y [0 to 255 / 0 / 1/step] 090 #PCU:Y 093 #Image Transfer Unit 094 ITB(Image Transfer Belt) 095 ITB Roller: K 096 ITB Roller: C [0 to 255 / 0 / 1/step] 097 ITB Roller: M 098 ITB Roller: Y 099 ITB Bias Roller...
  • Page 605 SP7-932 to 988 (Data Log) 120 Fusing Belt Smoothing Roller 124 #Fusing Cleaning Unit 125 Cleaning Web [0 to 255 / 0 / 1/step] 126 Web Cleaning Roller 127 Web Roller Stopper 130 #Main Unit Filters 131 Dust Filter:Large 132 Dust Filter:Small [0 to 255 / 0 / 1/step] 133 Ozone Filter 134 Deodorant Filter:Large...
  • Page 606 5. Main SP Tables-7 164 Pick-up Roller-Tray4 165 Feed Roller:Tray 4:Feeding Roller 166 Feed Roller:Tray 4:Separation Roller [0 to 255 / 0 / 1/step] 169 #Feed Roller:Bypass 170 Feed Roller:Bypass:Pick-up 171 Feed Roller:Bypass:Feeding Roller Feed Roller:Bypass:Separation Roller [0 to 255 / 0 / 1/step] 175 #Feed Roller:A3LCT 176 Feed Roller:A3LCT:Pick-up 177 Feed Roller:A3LCT:Feeding Roller...
  • Page 607 SP7-932 to 988 (Data Log) 201 Separation Roller:Interposer 202 Pick-up Roller:Interposer 205 #ADF [0 to 255 / 0 / 1/step] 206 ADF Feed Belt 207 ADF Separation Roller 208 ADF Pick-up Roller [0 to 255 / 0 / 1/step] [Operation Env. Log:PCU:Bk] 7963 Displays the distance of PCU: K in each Temperature/Humidity division in order to recognize Engine Operation Environment.
  • Page 608 5. Main SP Tables-7 016 25<=T<30:80<=H<=100 017 30<=T<35:0<=H<30 018 30<=T<35:30<=H<55 [0 to 999999 / 0 / 1m/step] 019 30<=T<35:55<=H<80 020 30<=T<35:80<=H<=100 021 35<=T [Operation Env. Log Clear] 7964 Clears all Operation Environment Logs. [- / - / -] 001 - [Execute] 7970 [Accumu Counter]...
  • Page 609 SP7-932 to 988 (Data Log) Transfer On-Off Drive Unit *ENG [0 to 99999999 / 0 / 1/step] Displays Operation Times Counter from when used initially. Feed Drive Unit *ENG [0 to 99999999 / 0 / 1page/step] Displays Pages Counter from when used initially. Registration Drive Unit *ENG [0 to 99999999 / 0 / 1page/step]...
  • Page 610 5. Main SP Tables-7 Transfer On-Off Drive Unit *ENG [0 to 200 / 0 / 1%/step] Displays the achievement degree to Yield Pages Threshold. Feed Drive Unit *ENG [0 to 200 / 0 / 1%/step] Displays the achievement degree to Yield Pages Threshold. Registration Drive Unit *ENG [0 to 200 / 0 / 1%/step]...
  • Page 611 SP7-932 to 988 (Data Log) [0 to 999999999 / 5080320 / 2nd Transfer Drive Unit *ENG 1m/step] Displays Yield Drive Distance Threshold for Drive Unit. [0 to 999999999 / 5080320 / Fusing Drive Unit *ENG 1m/step] Displays Yield Drive Distance Threshold for Drive Unit. Transfer On-Off Drive Unit *ENG [0 to 9999999 / 400000 / 1/step]...
  • Page 612 5. Main SP Tables-7 [0 to 999999999 / 5025000 / 005 Y Opc Drive Unit *ENG 1m/step] [0 to 999999999 / 5025000 / 006 Transfer Drive Unit *ENG 1m/step] [0 to 999999999 / 5025000 / 007 2nd Transfer Drive Unit *ENG 1m/step] [0 to 999999999 / 5025000 /...
  • Page 613 SP7-932 to 988 (Data Log) 003 Drum Motor:M *ENG [0 or 1 / 0 / 1/step] 004 Drum Motor:Y *ENG [0 or 1 / 0 / 1/step]...
  • Page 614 5. Main SP Tables-7...
  • Page 615: Main Sp Tables-8

    6. Main SP Tables-8 Keys and abbreviations in Data Log 2 Abbreviation What it means "By", e.g. "T:Jobs/Apl" = Total Jobs "by" Application > More (2> "2 or more", 4> "4 or more" AddBook Address Book Application Black & White Black Cyan ColCr...
  • Page 616 6. Main SP Tables-8 Abbreviation What it means Get Print Counter. For jobs 10 pages or less, this counter does not count up. For jobs larger than 10 pages, this counter counts up by the number that is in excess of 10 (e.g., for an 11-page job, the counter counts up 11-10 =1) IFax Internet Fax...
  • Page 617 Keys and abbreviations in Data Log 2 Abbreviation What it means Red (Toner Remaining). Applies to the wide format model A2 only. This machine is under development and currently not available. Resolution Service Code (Error SC code displayed) Scan Sim, Simplex Simplex, printing on 1 side.
  • Page 618: Sp8-Xxx (Data Log 2)

    6. Main SP Tables-8 SP8-XXX (Data Log 2) Many of these counters are provided for features that are currently not available, such as sending color faxes, and so on. However, here are some Group 8 codes that when used in combination with others, can provide useful information.
  • Page 619 SP8-XXX (Data Log 2) Other applications Refers to network applications such as Web Image (external network Monitor. Utilities developed with the SDK (Software applications, for Development Kit) will also be counted with this group in the example) future. The Group 8 SP codes are limited to 17 characters, forced by the necessity of displaying them on the small LCDs of printers and faxes that also use these SPs.
  • Page 620 6. Main SP Tables-8 • The F: counter does not distinguish between fax sending or receiving. • When a copy job on the document server is printed, SP8022 also increments, and when a print job stored on the document server is printed, SP8024 also increments. •...
  • Page 621 SP8-XXX (Data Log 2) 8021 [T:Pjob/LS] *CTL 8022 [C:Pjob/LS] *CTL These SPs reveal how files printed from the document server were stored on the 8023 [F:Pjob/LS] *CTL document server originally. 8024 [P:Pjob/LS] *CTL [0 to 9999999 / 0 / 1] The L: counter counts the number of jobs 8025 [S:Pjob/LS]...
  • Page 622 6. Main SP Tables-8 • When documents already stored on the document server are printed, the count for the application that started the print job is incremented. • When the print job is started from a network application (Desk Top Binder, Web Image Monitor, etc.) the L: counter increments.
  • Page 623 SP8-XXX (Data Log 2) [P:FIN Jobs] 8062 These SPs total finishing methods for print jobs only. The finishing method is specified by the application. [F:FIN Jobs] These SPs total finishing methods for fax jobs only. The finishing method is specified by 8063 the application.
  • Page 624 6. Main SP Tables-8 Booklet *CTL [0 to 9999999 / 0 / 1 / step] Number of jobs started in Booklet mode. If the machine is in staple mode, the Staple counter also increments. Z-Fold *CTL [0 to 9999999 / 0 / 1 / step] Number of jobs started In any mode other than the Booklet mode and set for folding (Z- fold).
  • Page 625 SP8-XXX (Data Log 2) [P:Jobs/PGS] 8074 These SPs count and calculate the number of print jobs by size based on the number of pages in the job. [S:Jobs/PGS] 8075 These SPs count and calculate the number of scan jobs by size based on the number of pages in the job.
  • Page 626 6. Main SP Tables-8 • For example: When a copy job stored on the document server is printed in document server mode, the appropriate L: counter (SP8076 0xx) increments. • Printing a fax report counts as a job and increments the F: counter (SP 8073). •...
  • Page 627 SP8-XXX (Data Log 2) [T:IFAX TX Jobs] These SPs count the total number of jobs (color or black-and-white) sent, either directly or 8121 using a file stored on the document server, as fax images using I-Fax. Note: Color fax sending is not available at this time. [F: IFAX TX Jobs] These SPs count the number of jobs (color or black-and-white) sent (not stored on the 8123...
  • Page 628 6. Main SP Tables-8 • If several jobs are combined for sending to the Scan Router, Scan-to-Email, or Scan-to-PC, or if one job is sent to more than one destination. Each send is counted separately. For example, if the same document is sent by Scan-to-Email as well as Scan-to-PC, then it is counted twice (once for Scan-to-Email and once for Scan-to-PC).
  • Page 629 SP8-XXX (Data Log 2) 002 Color *CTL [0 to 9999999 / 0 / 1 / step] 003 ACS *CTL [0 to 9999999 / 0 / 1 / step] • These counters count jobs, not pages. • If the job is cancelled during scanning, it is not counted. •...
  • Page 630 6. Main SP Tables-8 001 B/W *CTL [0 to 9999999 / 0 / 1 / step] 002 Color *CTL [0 to 9999999 / 0 / 1 / step] 003 ACS *CTL [0 to 9999999 / 0 / 1 / step] 8191 [T:Total Scan PGS] *CTL...
  • Page 631 SP8-XXX (Data Log 2) [S:LSize Scan PGS] *CTL [0 to 9999999 / 0 / 1 / step] These SPs count the total number of large pages input with the scanner for scan jobs only. 8205 Large size paper (A3/DLT) scanned for fax transmission are not counted. Note: These counters are displayed in the SMC Report, and in the User Tools display.
  • Page 632 6. Main SP Tables-8 Back *CTL [0 to 9999999 / 0 / 1 / step] Number of rear sides fed for scanning: With an ADF that can scan both sides simultaneously, the Back count is the same as the number of pages fed for duplex scanning. With an ADF that cannot scan both sides simultaneously, the Back count is the same as the number of pages fed for duplex rear-side scanning.
  • Page 633 SP8-XXX (Data Log 2) • If the user selects "Mixed Sizes" for copying in the platen mode, the Mixed Size count is enabled. • In the SADF mode if the user copies 1 page in platen mode and then copies 2 pages with SADF, the Platen count is 1 and the SADF count is 3.
  • Page 634 6. Main SP Tables-8 011 Other • If the scan mode is changed during the job, for example, if the user switches from ADF to Platen mode, the count is done for the last selected mode. 8251 [T:Scan PGS/ImgEdt] *CTL These SPs show how many times Image Edit features have been selected at the operation 8252...
  • Page 635 SP8-XXX (Data Log 2) 8281 [T:Scan PGS/TWAIN] *CTL These SPs count the number of pages scanned using a TWAIN driver. These counters reveal how the TWAIN driver is used for delivery functions. 8285 [S:Scan PGS/TWAIN] *CTL [0 to 9999999 / 0 / 1 / step] Note: At the present time, these counters perform identical counts.
  • Page 636 6. Main SP Tables-8 [L:Scan PGS/Size] These SPs count by size the total number of pages scanned and stored from within the 8306 document server mode screen at the operation panel, and with the Store File button from within the Copy mode screen. Use these totals to compare original page size (scanning) and output page size [SP 8-446].
  • Page 637 SP8-XXX (Data Log 2) 004 200dpi to 399dpi *CTL [0 to 9999999 / 0 / 1 / step] 005 < 199dpi *CTL [0 to 9999999 / 0 / 1 / step] • Copy resolution settings are fixed so they are not counted. •...
  • Page 638 6. Main SP Tables-8 8401 [T:PrtPGS/LS] *CTL These SPs count the number of pages printed from the document server. The counter for the 8402 [C:PrtPGS/LS] *CTL application used to print the pages is 8403 [F:PrtPGS/LS] *CTL incremented. The L: counter counts the number of jobs 8404 [P:PrtPGS/LS] *CTL...
  • Page 639 SP8-XXX (Data Log 2) [L:PrtPGS/Dup Comb] These SPs count by binding and combine, and n-Up settings the number of pages 8426 processed for printing from within the document server mode window at the operation panel. [O:PrtPGS/Dup Comb] 8427 These SPs count by binding and combine, and n-Up settings the number of pages processed for printing by Other applications 001 Simplex>...
  • Page 640 6. Main SP Tables-8 015 4-in-1 + Booklet *CTL [0 to 99999999 / 0 / 1 / step] 016 6-in-1 + Booklet *CTL [0 to 99999999 / 0 / 1 / step] 017 8-in-1 + Booklet *CTL [0 to 99999999 / 0 / 1 / step] 018 9-in-1 + Booklet *CTL [0 to 99999999 / 0 / 1 / step]...
  • Page 641 SP8-XXX (Data Log 2) [T:PrtPGS/ImgEdt] 8431 These SPs count the total number of pages output with the three features below, regardless of which application was used. [C:PrtPGS/ImgEdt] 8432 These SPs count the total number of pages output with the three features below with the copy application.
  • Page 642 6. Main SP Tables-8 [F:PrtPGS/Ppr Size] 8443 These SPs count by print paper size the number of pages printed by the fax application. [P:PrtPGS/Ppr Size] 8444 These SPs count by print paper size the number of pages printed by the printer application.
  • Page 643 SP8-XXX (Data Log 2) [PrtPGS/Ppr Tray] 8451 These SPs count the number of sheets fed from each paper feed station. Bypass Tray 001 Bypass Tray *CTL [0 to 99999999 / 0 / 1 / step] 002 Tray 1 *CTL Copier [0 to 99999999 / 0 / 1 / step] 003 Tray 2 *CTL...
  • Page 644 6. Main SP Tables-8 [T:PrtPGS/Ppr Type] These SPs count by paper type the number pages printed by all applications. • These counters are not the same as the PM counter. The PM counter is based on feed timing to accurately measure the service life of the feed rollers. However, these 8461 counts are based on output timing.
  • Page 645 SP8-XXX (Data Log 2) 001 < 49% *CTL 002 50% to 99% *CTL 003 100% *CTL [0 to 99999999 / 0 / 1 / step] 004 101% to 200% *CTL 005 201% < *CTL Counts are done for magnification adjusted for pages, not only on the operation panel but performed remotely with an external network application capable of performing magnification adjustment as well.
  • Page 646 6. Main SP Tables-8 8501 [T:PrtPGS/Col Mode] 8504 [P:PrtPGS/Col Mode] 8507 [O:PrtPGS/Col Mode] 001 B/W *CTL 002 Mono Color *CTL These SPs count the number of pages printed 003 Full Color *CTL in the Color Mode by the print application. 004 Single Color *CTL 005 Two Color...
  • Page 647 SP8-XXX (Data Log 2) 014 Other *CTL [0 to 99999999 / 0 / 1 / step] 015 IPDS *CTL [0 to 99999999 / 0 / 1 / step] • SP8 511 and SP8 514 return the same results as they are both limited to the Print application. •...
  • Page 648 6. Main SP Tables-8 007 Other *CTL [0 to 99999999 / 0 / 1 / step] Inside Fold *CTL [0 to 99999999 / 0 / 1 / step] Half-Fold (FM2) (Multi Fold Unit) Three-IN-Fold *CTL [0 to 99999999 / 0 / 1 / step] Letter Fold-in (FM4) (Multi Fold Unit) Three-OUT-Fold *CTL...
  • Page 649 SP8-XXX (Data Log 2) 8552 [C:FIN Books] 001 Perfect-Bind *CTL Booklet finishing Not used 002 Ring-Bind *CTL 8554 [P:FIN Books] 001 Perfect-Bind *CTL Booklet finishing Not used 002 Ring-Bind *CTL 8556 [L:FIN Books] 001 Perfect-Bind *CTL Booklet finishing Not used 002 Ring-Bind *CTL 8561...
  • Page 650 6. Main SP Tables-8 001 Total: Over A3/DLT *CTL 002 Total: Under A3/DLT *CTL [0 to 99999999 / 0 / 1] 003 Duplex: Over A3/DLT *CTL 004 Duplex: Under A3/DLT *CTL 8564 [P:A Sheet Of Paper] 001 Total: Over A3/DLT *CTL 002 Total: Under A3/DLT *CTL...
  • Page 651 SP8-XXX (Data Log 2) 001 Total *CTL 002 Total: Full Color *CTL 003 B&W/Single Color *CTL 004 Development: CMY *CTL [0 to 99999999 / 0 / 1] 005 Development: K *CTL 008 Print: Color *CTL 009 Print: B/W *CTL 010 Total: Color *CTL 011 Total: B/W *CTL...
  • Page 652 6. Main SP Tables-8 027 Total: Color (Eco FC) *CTL 028 Development: CMY (A3) *CTL 029 Development: K (A3) *CTL [0 to 99999999 / 0 / 1] 030 Total: Color (A3) *CTL 031 Total: B/W (A3) *CTL [C:Counter] 8582 These SPs count the total output of the copy application broken down by color output. 001 B/W *CTL 002 Mono Color...
  • Page 653 SP8-XXX (Data Log 2) 001 B/W *CTL 002 Mono Color *CTL 003 Full Color *CTL [0 to 99999999 / 0 / 1] 004 Single Color *CTL 005 Two Color *CTL [L:Counter] 8586 These SPs count the total output of the local storage broken down by color output. 001 B/W *CTL 002 Mono Color...
  • Page 654 6. Main SP Tables-8 021 CvgCounter 1 *CTL 022 CvgCounter 2 *CTL [0 to 9999999 / 0 / 1 / step] 023 CvgCounter 3 *CTL 031 CvgCounter 1(YMC) *CTL 032 CvgCounter 2(YMC) *CTL [0 to 9999999 / 0 / 1 / step] 033 CvgCounter 3(YMC) *CTL [C:CvgCounter]...
  • Page 655 SP8-XXX (Data Log 2) [L:CvgCounter] 8606 001 Cvg: B/W % *CTL 002 Cvg: Single Color % *CTL [0 to 2147483647 / 0 / 1% / step] 003 Cvg: Two Color % *CTL 004 Cvg: Full Color % *CTL [SDK Apli Counter] 8617 These SPs count the total printout pages for each SDK application.
  • Page 656 6. Main SP Tables-8 006 Function-006 *CTL 007 Function-007 *CTL 008 Function-008 *CTL [0 to 99999999 / 0 / 1 / step] 009 Function-009 *CTL 010 Function-010 *CTL 011 Function-011 *CTL 012 Function-012 *CTL 013 Function-013 *CTL [0 to 99999999 / 0 / 1 / step] 014 Function-014 *CTL 015 Function-015...
  • Page 657 SP8-XXX (Data Log 2) 031 Function-031 *CTL 032 Function-032 *CTL 033 Function-033 *CTL 034 Function-034 *CTL 035 Function-035 *CTL [0 to 99999999 / 0 / 1 / step] 036 Function-036 *CTL 037 Function-037 *CTL 038 Function-038 *CTL 039 Function-039 *CTL 040 Function-040 *CTL 041 Function-041...
  • Page 658 6. Main SP Tables-8 051 Function-051 *CTL 052 Function-052 *CTL 053 Function-053 *CTL 054 Function-054 *CTL 055 Function-055 *CTL [0 to 99999999 / 0 / 1 / step] 056 Function-056 *CTL 057 Function-057 *CTL 058 Function-058 *CTL 059 Function-059 *CTL 060 Function-060 *CTL 061 Function-061...
  • Page 659 SP8-XXX (Data Log 2) • At the present time, this feature is provided for the Fax application only so SP8631 and SP8633 are the same. • The counts include error pages. • If a document is sent to more than one destination with a Group transmission, the count is done for each destination.
  • Page 660 6. Main SP Tables-8 002 Color *CTL [0 to 9999999 / 0 / 1 step] [S:S-to-Email PGS] 8655 These SPs count by color mode the total number of pages attached to an e-mail for both the Scan and document server applications. 001 B/W *CTL [0 to 9999999 / 0 / 1 step]...
  • Page 661 SP8-XXX (Data Log 2) • The B/W and Color counts are done after the document is stored on the HDD of the Scan Router server. • If the job is canceled before storage on the Scan Router server finishes, the counts are not done. •...
  • Page 662 6. Main SP Tables-8 • Print jobs done with Web Image Monitor and Desk Top Binder are added to the count. • If several documents are merged for sending, the number of pages stored are counted for the application that stored them. •...
  • Page 663 SP8-XXX (Data Log 2) [S: Dvliv PGS/WSD] 8725 These SPs count the number of pages scanned by each scanner mode. 001 B/W *CTL [0 to 9999999/ 0 / 1 / step] 002 Color *CTL [0 to 9999999/ 0 / 1 / step] 8731 [T:Scan PGS/Media] [S:Scan PGS/Media]...
  • Page 664 6. Main SP Tables-8 [Toner_Bottle_Info.] These SPs display the number of already replaced toner bottles. 8781 NOTE: Currently, the data in SP7-833-011 through 014 and the data in SP8-781-001 through 004 are the same. Toner: BK *ENG [0 to 9999999 / 0 / 1 / step] The number of black-toner bottles Toner: Y *ENG...
  • Page 665 SP8-XXX (Data Log 2) 001 Eco Total *CTL 002 Color *CTL 003 Full Color *CTL [0 to 99999999 / 0 / 1 / step] 004 Duplex *CTL 005 Combine *CTL 006 Color (%) *CTL 007 Full Color (%) *CTL 008 Duplex (%) *CTL [0 to 100 / 0 / 1% / step] 009 Combine (%)
  • Page 666 6. Main SP Tables-8 011 0 to 2%: BK *ENG 012 0 to 2%: Y *ENG [0 to 99999999 / 0 / 1 / step] 013 0 to 2%: M *ENG 014 0 to 2%: C *ENG 021 3 to 4%: BK *ENG 022 3 to 4%: Y *ENG...
  • Page 667 SP8-XXX (Data Log 2) [Cvr Cnt: 21-30%] 8871 These SPs display the number of scanned sheets on which the coverage of each color is from 21% to 30%. 001 BK *ENG 002 Y *ENG [0 to 99999999 / 0 / 1 / step] 003 M *ENG 004 C...
  • Page 668 6. Main SP Tables-8 001 BK *ENG 002 Y *ENG [0 to 99999999 / 0 / 1 / step] 003 M *ENG 004 C *ENG [Page/Ink_prev2] 8911 These SPs display the amount of the remaining 2nd previous toner for each color. 001 BK *ENG 002 Y...
  • Page 669 SP8-XXX (Data Log 2) Operation Time *CTL [0 to 99999999 / 0 / 1 / step] Engine operation time. Does not include time while controller is saving data to HDD (while engine is not operating). Standby Time *CTL [0 to 99999999 / 0 / 1 / step] Engine not operating.
  • Page 670 6. Main SP Tables-8 Mail Address *CTL [0 to 9999999/ 0 / 1 / step] Mail address registrations. Fax Destination *CTL [0 to 9999999/ 0 / 1 / step] Fax destination registrations. Group *CTL [0 to 9999999/ 0 / 1 / step] Group destination registrations.
  • Page 671 SP8-XXX (Data Log 2) 005 Printing Time *CTL 006 Reading Time *CTL 007 Eng Waiting Time *CTL 008 Low Power State Time *CTL [0 to 99999999 / 0 / 1 / step] 009 Silent State Time *CTL 010 Heater Off State Time *CTL 011 LCD on Time *CTL...
  • Page 672 6. Main SP Tables-8 012 A3/DLT *CTL [0 to 99999999 / 0 / 1 / step] 013 Duplex *CTL [0 to 99999999 / 0 / 1 / step] 014 Cvg:FC % *CTL [0 to 2147483647 / 0 / 1% / step] 015 Cvg:BW % *CTL [0 to 2147483647 / 0 / 1% / step]...
  • Page 673: Input And Output Check

    7. Input and Output Check Input Check Table 5803 [INPUT Check] [0 to 255 / 0 / 1/step] • Bit 0: ITB PP error detection K (0: Normal, 1: SC detected) • Bit 1: ITB PP error detection C (0: Normal, 1: SC detected) •...
  • Page 674 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0 to 2: Not used • Bit 3: PCU set detection: K (0: Set, 1: Not set) • Bit 4: PCU set detection: C (0: PIBPort08 Set, 1: Not set) •...
  • Page 675 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Heat Pipe Intake Fan (0: Not normal, 1: Normal) • Bit 1: Heat Pipe Exhaust Fan (0: Normal, 1: Not normal) • Bit 2: Development Exhaust Fan/right (0: Not normal, 1: Normal) •...
  • Page 676 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: Lubricant Near End Switch/K (0: Near End, 1: Normal) • Bit 1: Lubricant Near End Switch/C (0: Near End, 1: Normal) • Bit 2: Lubricant Near End Switch/M (0: Near End, 1: Normal) PIBPort23...
  • Page 677 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Development Bias Error Detection K (0: Normal, 1: SC detected) • Bit 1: Development Bias Error Detection C (0: Normal, 1: SC detected) • Bit 2: Development Bias Error Detection M (0: Normal, 1: SC detected) •...
  • Page 678 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: OPC Home Position Sensor C (0: Not detected, 1: Home Position detected) • Bit 1: Development Sleeve Home Position Sensor C (0: Not detected, 1: Home Position detected) •...
  • Page 679 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Not used • Bit 1: Fusing Unit Specification 0 (Voltage 100V/200V) (0: 200V, 1: 100V) • Bit 2: Not used • Bit 3: Fusing Unit Specification 2 (Type) (0: Pro, 1: Office) •...
  • Page 680 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: Not used • Bit 1: PSU Fan/right (0: Normal, 1: Stopped/Lock detected) • Bit 2: PSU Fan/left (0: Normal, 1: Stopped/Lock detected) • Bit 3: IH Power Cooling Fan (0: Stopped/Lock detected, 1: Normal) FSBPort13...
  • Page 681 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0 to 2: Not used • Bit 3: Heat Pipe Set Detection (0: Set, 1: Unset) • Bit 4: Waste Toner Bottle Lock Sensor (0: Blocked, 1: FSBPort22 Unblocked) •...
  • Page 682 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: Refresh Roller Drive Motor (0: Normal, 1: Error) • Bit 1: Refresh Roller Contact Sensor (0: Out of Home, 1: Home) FSBPort28 • Bit 2: FDB_M Set Detection (0: Set, 1: Unset) •...
  • Page 683 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Zero Cross 2 (0: Zero Cross detected, 1: Not detected) FSBEXINT • Bit 1 to 4: Not used • Bit 5: Interlock Door Open/ Close (0: Door Closed, 1: Door Open) •...
  • Page 684 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: 1st Transport Sensor (0: Paper, 1: No paper) • Bit 1: 2ndTransport Sensor (0: Paper, 1: No paper) • Bit 2: 3rd Transport Sensor (0: Paper, 1: No paper) •...
  • Page 685 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Tandem Tray Left Set Detection (0: Set, 1: Unset) • Bit 1: Not used • Bit 2: Bypass Door Open/ Close Sensor (0: Door closed, 1: Door open) •...
  • Page 686 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0 to 5: Not used PFB_V1Port27 • Bit 6: Duplex Inverter Sensor (0: Paper, 1: No Paper) • Bit 7: Not used Displays data register value for PFB_VODKA1 Port27 [0 to 255 / 0 / 1/step] •...
  • Page 687 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Bypass Paper End Sensor (0: Paper, 1: No paper) • Bit 1: Mainframe LED-SW Left PFB_V2Port11 (SW) (0: ON, 1: OFF) • Bit 2: Mainframe LED-SW Right (SW (SW) (0: ON, 1: OFF) •...
  • Page 688 7. Input and Output Check Combination 1 Sensor output signal Bypass Sub Scan Bypass Main Scan Length Sensor Length Sensor Detected size ON: 0 (Unblocked) OFF: 1 (Blocked) Postcard SEF B6 SEF A5 SEF B5 SEF A4 SEF A5 LEF B4 SEF B5 LEF A3 SEF...
  • Page 689 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0 to 1: Not used • Bit 2: Fusing Web Contact PFB_V2Port14 Sensor (0: No contact, 1: Contact) • Bit 3 to 7: Not used Displays data register value for PFB_VODKA2 Port14 [0 to 255 / 0 / 1/step] •...
  • Page 690 7. Input and Output Check Combination 2 Paper Height Paper Feed Tray Operation Ratio (100 Sensor Remaining Paper End panel display when full)* Sensor 4 horizontal 100% 0 (Blocked) 100 to 71 bars 3 horizontal 0 (Blocked) 70 to 31 bars 2 horizontal 9 (Blocked)
  • Page 691 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Tray 1 Upper Limit Sensor (0: Paper Height Not Reached, 1: Paper Height Reached) • Bit 1: Tray 2 Upper Limit Sensor (0: Paper Height Not Reached, 1: Paper Height Reached) •...
  • Page 692 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: Sensor Shift Home Position Sensor (Rise) (0: Not detected, 1: Home Position detected) • Bit 1 to 2: Not used • Bit 3: Edge Sensor 1 (0: Paper Edge detected, 1: Paper Edge not detected) •...
  • Page 693 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Not used • Bit 1: Rear End Fence Closed Sensor (0: End Fence Open, 1: End Fence Closed) • Bit 2: Lower Limit Sensor (Tandem) (0: Not lower limit, 1: Lower limit) PFB_V3Port07 •...
  • Page 694 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: Paper Exit Full Sensor (0: Not full, 1: Full) • Bit 1: Paper Exit Relay Sensor PFB_V3Port15 (0: Paper, 1: No paper) • Bit 2: Inverter Exit Sensor (0: Paper, 1: No paper) •...
  • Page 695 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Tray 4 Paper Size SW Knob 4 • Bit 1: Tray 4 Paper Size SW Knob 3 • Bit 2: Tray 4 Paper Size SW Knob 2 •...
  • Page 696 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: Tray 2 Paper Size SW Knob 4 • Bit 1: Tray 2 Paper Size SW Knob 3 • Bit 2: Tray 2 Paper Size SW Knob 2 •...
  • Page 697 Input Check Table Combination 3 Board Information Paper Size Knob 4 Knob 3 Knob 2 Knob 1 13” x 19” SRA3 (12” x 18”) A3 (DLT) (LG) A4_SEF LT_SEF B5_SEF A4_LEF (LT_LEF) B5_LEF (Exe_LEF) A5_LEF (HLT_LEF) [0 to 255 / 0 / 1/step] PFB_V3Port22 •...
  • Page 698 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0 to 1: Not used • Bit 2: Roller Home Position Sensor 1 (0:Not detected, 1: Home Position detected) • Bit 3: Roller Home Position Sensor 2 (0: Not detected, 1: Home Position detected) PFB_V3Port25 •...
  • Page 699 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Not used • Bit 1: Registration Sensor (Paper Feed-out) (0: Paper, 1: No paper) • Bit 2: Duplex Entrance Sensor (0: Paper, 1: No paper) • Bit 3: Registration Sensor (Paper Feed-in) (0: Paper, 1: PFB_V3Port EXINT No paper)
  • Page 700 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: IH Coil Cooling Fan Error Detection (0: Error, 1: Normal) • Bit 1: Fusing Pressure Roller Intake Fan Error Detection (0: Normal, 1: Error) • Bit 2: Paper Cooler HP Cooling Fan Error Detection (0: Not normal, 1: Normal) •...
  • Page 701 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Inverter Exit Sensor (0: Paper, 1: No paper) • Bit 1: Duplex Exit Sensor (0: Paper, 1: No paper) • Bit 2: Duplex Transport Sensor1 (0: Paper, 1: No paper) •...
  • Page 702 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0 to 5: Not used • Bit 6: Edge Sensor1 (0: Paper, DUB_Port07 1: No paper) • Bit 7: Purge Relay Sensor (0: Paper, 1: No paper) Displays data register value for DUB_VODKA Port07 [0 to 255 / 0 / 1/step] •...
  • Page 703 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Fusing Exit Guide Plate Open/Close Sensor (0: Closed, 1: Open) • Bit 1: Not used • Bit 2: Paper Exit Left Guide Plate Open/Close Sensor (0: Closed, 1: Open) •...
  • Page 704 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: Development Intake Fan K Error Detection (0: Not normal, 1: Normal) • Bit 1: Development Intake Fan C Error Detection (0: Not normal, 1: Normal) •...
  • Page 705 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0 to 1: Not used PIBPort15 • Bit 2: Lubricant Unit Detection K (0: Set, 1: Unset) • Bit 3 to 7: Not used Displays data register value for PIB_VODKA Port08 [0 to 255 / 0 / 1/step] •...
  • Page 706 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: Remaining Detection Sensor 1 (0: Not Detected, 1: Detected) • Bit 1: Remaining Detection Sensor 2 (0: Not Detected, 1: Detected) • Bit 2: Remaining Detection Sensor 3 (0: Not Detected, 1: Detected) A3LCT-CPU-Port2...
  • Page 707 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: DIPSW1 (0: ON, 1: OFF) • Bit 1: DIPSW2 (0: ON, 1: OFF) • Bit 2: DIPSW3 (0: ON, 1: OFF) • Bit 3: DIPSW4 (0: ON, 1: A3LCT-CPU-Port4 OFF) •...
  • Page 708 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: - • Bit 1: - • Bit 2: - A3LCT-CPU-PortB • Bit 3: - • Bit 4: - • Bit 5: Tray Set (0: Set, 1: Unset) •...
  • Page 709 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: - • Bit 1: - • Bit 2: - • Bit 3: - A3LCT-CPU-PortE • Bit 4: - • Bit 1: - • Bit 6: - • Bit 7: Feed Motor STS0 (0: Ready, 1: E2PROM Download) Checks Not Normal/Normal condition for Exit Motor.
  • Page 710 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: - • Bit 1: - • Bit 2: Feed Motor STS0 (0: Ready, 3: E2PROM Download) A3LCT-CPU-PortG • Bit 3: Transport Motor FAULT (0: Normal, 1: Not Normal) •...
  • Page 711 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Remaining Detection Sensor 1 (0: Not Detected, 1: Detected) • Bit 1: Remaining Detection Sensor 2 (0: Not Detected, 1: Detected) • Bit 2: Remaining Detection Sensor 3 (0: Not Detected, 1: A3LCT-CPU-Port2 Detected) •...
  • Page 712 7. Input and Output Check [0 to 255 / 0 / 1/step] • Bit 0: - • Bit 1: Paper Supply Cover opening-closing SW (0: Close, 1: Open) • Bit 2: - A3LCT-CPU-PortC • Bit 3: - • Bit 4: - •...
  • Page 713 Input Check Table [0 to 255 / 0 / 1/step] • Bit 0: Feed Motor STS0 (0: Ready, 1: E2PROM Download) • Bit 1: Transport Motor FAULT (0: Not Normal, 1: Normal) A3LCT-CPU-PortF • Bit 2: - • Bit 3: - •...
  • Page 714 7. Input and Output Check Tray 2 Set Sensor [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. Tray 3 Set Sensor [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. Tray 4 Set Sensor [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc.
  • Page 715 Input Check Table Left Tray Paper Detect Sensor [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. Tray 1: Upper Limit Sensor [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. Tray 2: Upper Limit Sensor [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc.
  • Page 716 7. Input and Output Check Tray 4 Paper Height Detection 1 [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. Tray 4 Paper Height Detection 2 [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. Tray 1 Transport HP Detection Sn [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc.
  • Page 717 Input Check Table Transport Sensor 4 [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. Main Unit Relay Sensor [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. Registration Sensor [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc.
  • Page 718 7. Input and Output Check Duplex Transport Sensor 1 [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. Duplex Transport Sensor 2 [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. Duplex Transport Sensor 3 [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc.
  • Page 719 Input Check Table [0 to 31 / 0 / 1/step] Paper Feed 1 Motor Error 1: Detected 0: Not Detected Displays the presence of Motor Error. [0 to 31 / 0 / 1/step] Paper Feed 2 Motor Error 1: Detected 0: Not Detected Displays the presence of Motor Error.
  • Page 720 7. Input and Output Check [0 to 31 / 0 / 1/step] Transport Motor 3 Error 1: Detected 0: Not Detected Displays the presence of Motor Error. [0 to 31 / 0 / 1/step] Transport Motor 4 Error 1: Detected 0: Not Detected Displays the presence of Motor Error.
  • Page 721 Input Check Table [0 to 31 / 0 / 1/step] Duplex Inverter Motor Error 1: Detected 0: Not Detected Displays the presence of Motor Error. [0 to 31 / 0 / 1/step] Duplex Transport Motor Error 1: Detected 0: Not Detected Displays the presence of Motor Error.
  • Page 722 7. Input and Output Check Main Unit LED-SW Left (LED) [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. Main Unit LED-SW Right (LED) [0 or 1 / 0 / 1/step] Displays detection condition for the sensors, SW etc. HP Senser [0 or 1 / 0 / 1/step] Executes operation check for Scanner HP Sensor.
  • Page 723 Input Check Table Buffer Pass Unit:CTB_H8S-PortD [0 to 255 / 0 / 1/step] Buffer Pass Unit CTB_H8S-PortD Buffer Pass Unit:CTB_H8S-PortE [0 to 255 / 0 / 1/step] Buffer Pass Unit CTB_H8S-PortE 6011 [1-Pass ADF INPUT Check] Original Length 1 (B5 Sensor) [0 or 1 / 0 / 1/step] Acquires Sensor information for ADF.
  • Page 724 7. Input and Output Check Skew Correction [0 or 1 / 0 / 1/step] Acquires Sensor information for ADF. Turns to "1" when the original is in Sensor part. Scan Entrance Sensor [0 or 1 / 0 / 1/step] Acquires Sensor information for ADF. Turns to "1" when the original is in Sensor part. Registration Sensor [0 or 1 / 0 / 1/step] Acquires Sensor information for ADF.
  • Page 725 Input Check Table Horizontal Transport Sensor [0 or 1 / 0 / 1/step] Acquires Sensor information for the specified sensors. Displays signal level for Sensors as it Switchback Transport Sensor [0 or 1 / 0 / 1/step] Acquires Sensor information for the specified sensors. Displays signal level for Sensors as it Proof Exit Sensor [0 or 1 / 0 / 1/step] Acquires Sensor information for the specified sensors.
  • Page 726 7. Input and Output Check Lower Junction Solenoid HP [0 or 1 / 0 / 1/step] Sensor Acquires Sensor information for the specified sensors. Displays signal level for Sensors as it Jogger Fence HP Sensor [0 or 1 / 0 / 1/step] Acquires Sensor information for the specified sensors.
  • Page 727 Input Check Table Bklet Stapler HP Sensor [0 or 1 / 0 / 1/step] Acquires Sensor information for the specified sensors. Displays signal level for Sensors as it Folder Blade Cam HP Sensor [0 or 1 / 0 / 1/step] Acquires Sensor information for the specified sensors.
  • Page 728 7. Input and Output Check Staple Tray Paper Sensor [0 or 1 / 0 / 1/step] Acquires Sensor information for the specified sensors. Displays signal level for Sensors as it ITB Paper Sensor [0 or 1 / 0 / 1/step] Acquires Sensor information for the specified sensors.
  • Page 729 Input Check Table Booklet Stapler Full Sensor 2 [0 or 1 / 0 / 1/step] Acquires Sensor information for the specified sensors. Displays signal level for Sensors as it Punch Registratioin Detection [0 or 1 / 0 / 1/step] Sensor Acquires Sensor information for the specified sensors.
  • Page 730 7. Input and Output Check Shift Tray Lower Limit Sensor 3 [0 or 1 / 0 / 1/step] Acquires Sensor information for the specified sensors. Displays signal level for Sensors as it Shift Tray Lower Limit Sensor 4 [0 or 1 / 0 / 1/step] Acquires Sensor information for the specified sensors.
  • Page 731 Input Check Table Dynamic Roller Open/Close [0 or 1 / 0 / 1/step] Guide Plate Sensor Acquires Sensor information for the specified sensors. Displays signal level for Sensors as it Tray Upper Limit SW [0 or 1 / 0 / 1/step] Acquires information for the specified switches.
  • Page 732 7. Input and Output Check [0 or 1 / 0 / 1/step] 005 Tray Lower Limit Sensor Other = 0 Lower Limit = 1 [0 or 1 / 0 / 1/step] 006 Shift Tray Near Full Sensor Other = 0 Lower Limit = 1 [0 or 1 / 0 / 1/step] 007 Feed-Out Belt HP Sensor...
  • Page 733 Input Check Table [0 or 1 / 0 / 1/step] 015 Punch Detection Sensor Not Changed = 0 Changed = 1 [0 or 1 / 0 / 1/step] 016 Punch HP Sensor 1 Home = 0 Other = 1 [0 or 1 / 0 / 1/step] 017 Punch-out Hopper Full Sensor Not Full = 0 Full = 1...
  • Page 734 7. Input and Output Check [0 or 1 / 0 / 1/step] 025 Stack Plate HP Sensor (Center) Home = 0 Other = 1 [0 or 1 / 0 / 1/step] 026 Exit Guide Open Sensor Home = 0 Other = 1 [0 or 1 / 0 / 1/step] 027 Stapler Rotation Sensor 2 Home = 0...
  • Page 735 Input Check Table [0 or 1 / 0 / 1/step] 035 Punch HP Sensor 2 Home = 0 Other = 1 [0 or 1 / 0 / 1/step] 036 Shift Jogger Sensor Not Changed = 0 Changed = 1 [0 or 1 / 0 / 1/step] 037 Shift Jogger HP Sensor Home = 0 Other = 1...
  • Page 736 7. Input and Output Check [0 or 1 / 0 / 1/step] 045 Staple Junction Gate HP Sensor Home = 0 Other = 1 [0 or 1 / 0 / 1/step] 046 Pre-Stack Junction Gate HP Sensor Home = 0 Other = 1 [0 or 1 / 0 / 1/step] 047 Pre-Stack Sensor (Right)
  • Page 737 Input Check Table 008 Paper Overflow Sn 3 [0 or 1 / 0 / 1/step] 009 Paper Detect Sn 4 [0 or 1 / 0 / 1/step] 010 Vert Transport Sn3:Bin5 [0 or 1 / 0 / 1/step] 011 Paper Overflow Sn 4 [0 or 1 / 0 / 1/step] 012 Paper Detect Sn 5 [0 or 1 / 0 / 1/step]...
  • Page 738 7. Input and Output Check [0 or 1 / 0 / 1/step] Paper Near End Sensor 1: Near End [0 or 1 / 0 / 1/step] Paper Set Sensor 0: Paper Detected [0 or 1 / 0 / 1/step] Bottom Plate HP Sensor 1:HP [0 or 1 / 0 / 1/step] Grip Sensor...
  • Page 739 Input Check Table Length Sensor 1 [0 or 1 / 0 / 1/step] Sensor for detecting the length of the paper set Length Sensor 2 [0 or 1 / 0 / 1/step] Sensor for detecting the length of the paper set Length Sensor 3 [0 or 1 / 0 / 1/step] Sensor for detecting the length of the paper set...
  • Page 740 7. Input and Output Check [0 or 1 / 0 / 1/step] 005 Dynamic Roller HP Sensor 1:HP [0 or 1 / 0 / 1/step] 006 Registration Roller HP Sensor 1:HP [0 or 1 / 0 / 1/step] 007 Fold Plate HP Sensor 1:HP [0 or 1 / 0 / 1/step] 008 Jogger Fence HP Sensor...
  • Page 741 Input Check Table [0 or 1 / 0 / 1/step] 020 Horizontal Path Exit Sensor 0: Detected [0 or 1 / 0 / 1/step] 021 Top Tray Full Sensor (E) 1: Detected [0 or 1 / 0 / 1/step] 023 Front Door Switch (SW1) 0: Close [0 or 1 / 0 / 1/step] 024 Horizontal Path Paper Sensor...
  • Page 742 7. Input and Output Check 012 1st Upper Limit Sensor [0 or 1 / 0 / 1/step] 013 2nd Upper Limit Sensor [0 or 1 / 0 / 1/step] 014 1st Lower Limit Sensor [0 or 1 / 0 / 1/step] 015 2nd Lower Limit Sensor [0 or 1 / 0 / 1/step] 016 1st Paper Near End Sensor...
  • Page 743: Output Check Table

    Output Check Table Output Check Table [Output Check] 5804 Polygon Motor: KC [0 or 1 / 0 / 1/step] KC: Polygon OUTPUT Check KC: Polygon ON for "1" Polygon Motor: MY [0 or 1 / 0 / 1/step] MY: Polygon OUTPUT Check MY: Polygon ON for "1"...
  • Page 744 7. Input and Output Check LCT:Exit Mtr:Feed [0 or 1 / 0 / 1/step] Speed2:550mm/sec Drives LCT Exit Motor at Feed Speed. LCT:Exit Mtr:Feed [0 or 1 / 0 / 1/step] Speed1:352.8mm/sec Drives LCT Exit Motor at Process Speed. A3LCT: Front Fan [0 or 1 / 0 / 1/step] Turns A3LCT Front Fan ON.
  • Page 745 Output Check Table Buffer Pass Unit:Cool Fan 1-2 [0 or 1 / 0 / 1/step] Operation Check Mode for Buffer Pass Unit:Cool Fan 1-2 (ON/OFF) Buffer Pass Unit:Exhaust Fan 1-2 [0 or 1 / 0 / 1/step] Operation Check Mode for Buffer Pass Unit:Exhaust Fan 1-2 (ON/OFF) Buffer Pass Unit:Cool Fan 3-4 [0 or 1 / 0 / 1/step] Operation Check Mode for Buffer Pass Unit:Cool Fan 3-4 (ON/OFF)
  • Page 746 7. Input and Output Check [0 or 1 / 0 / 1/step] Controller Exhaust Fan:Half Spd 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Controller Suction Fan:Full Spd 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown.
  • Page 747 Output Check Table [0 or 1 / 0 / 1/step] ImagingCooling Fan:Right 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] ImagingCooling Fan:Left 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] ITB Cooling Fan:Full Spd 1:ON(Active)
  • Page 748 7. Input and Output Check [0 or 1 / 0 / 1/step] Ozone Fan 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Duplex Exhaust Fan Front:Full 1:ON(Active) Speed 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Duplex Exhaust Fan Front:Half 1:ON(Active)
  • Page 749 Output Check Table [0 or 1 / 0 / 1/step] Transfer Fusing Exharst Fan:Half 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] IH Power Cooling Fan:Full Spd 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] IH Power Cooling Fan:Half Spd 1:ON(Active)
  • Page 750 7. Input and Output Check [0 or 1 / 0 / 1/step] Fus Press Roller Exhaust Fan:Half 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] PT Fan Front/Rear 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown.
  • Page 751 Output Check Table [0 or 1 / 0 / 1/step] Dev Fan Y: Full 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Dev Fan Y: Half 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Dev Fan M: Full 1:ON(Active)
  • Page 752 7. Input and Output Check [0 or 1 / 0 / 1/step] Dev Fan K: Half 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Toner Bottle Motor Y 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown.
  • Page 753 Output Check Table [0 or 1 / 0 / 1/step] Toner Feed Bottle Motor C 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Toner Feed Bottle Motor K 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown.
  • Page 754 7. Input and Output Check [0 or 1 / 0 / 1/step] K Drum Motor: Normal Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Y Drum Motor: Middle Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown.
  • Page 755 Output Check Table [0 or 1 / 0 / 1/step] M Drum Motor: Middle-Low 1:ON(Active) Speed *D136 only 0:OFF(Stop) This SP is only for D136 machine. Executing this SP on D135/D137/D138 machines may cause SC error. Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] C Drum Motor: Middle-Low Speed 1:ON(Active)
  • Page 756 7. Input and Output Check [0 or 1 / 0 / 1/step] K Drum Motor: Low Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Y DrumCln Motor: Normal Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown.
  • Page 757 Output Check Table [0 or 1 / 0 / 1/step] C DrumCln Motor: Middle Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] K DrumCln Motor: Middle Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown.
  • Page 758 7. Input and Output Check [0 or 1 / 0 / 1/step] K DrumCln Motor: Middle-Low 1:ON(Active) Speed *D136 only 0:OFF(Stop) This SP is only for D136 machine. Executing this SP on D135/D137/D138 machines may cause SC error. Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Y DrumCln Motor: Low Speed 1:ON(Active)
  • Page 759 Output Check Table [0 or 1 / 0 / 1/step] M Dev Motor: Normal Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] C Dev Motor: Normal Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown.
  • Page 760 7. Input and Output Check [0 or 1 / 0 / 1/step] Y Dev Motor: Middle-Low Speed 1:ON(Active) *D136 only 0:OFF(Stop) This SP is only for D136 machine. Executing this SP on D135/D137/D138 machines may cause SC error. Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] M Dev Motor: Middle-Low Speed 1:ON(Active)
  • Page 761 Output Check Table [0 or 1 / 0 / 1/step] M Dev Motor: Low Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] C Dev Motor: Low Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown.
  • Page 762 7. Input and Output Check [0 or 1 / 0 / 1/step] ITB Motor: Low Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] PTR Motor: Normal Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown.
  • Page 763 Output Check Table PTR Lift Motor:Detach [0 or 1 / 0 / 1/step] Attachment Operation when executing [0 or 1 / 0 / 1/step] Fuzing Motor: Normal Speed 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Fuzing Motor: Middle Speed 1:ON(Active) 0:OFF(Stop)
  • Page 764 7. Input and Output Check [0 or 1 / 0 / 1/step] PCL_Y 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] PCL_M 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] PCL_C 1:ON(Active)
  • Page 765 Output Check Table Exit/Inverter JG SOL [0 or 1 / 0 / 1/step] Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. 1st Left Tray Lock SOL [0 or 1 / 0 / 1/step] Operates load for Motors and SOL etc.
  • Page 766 7. Input and Output Check [0 or 1 / 0 / 1/step] Paper Exit Left Guide Board LED ON: Lighting OFF: Extinction Executes OUTPUT Check. [0 or 1 / 0 / 1/step] PurgeSecLowerGuideBoardLED ON: Lighting OFF: Extinction Executes OUTPUT Check. [0 or 1 / 0 / 1/step] PurgeSecUpperGuideBoardLED ON: Lighting...
  • Page 767 Output Check Table [0 or 1 / 0 / 1/step] RegistUpperGuideBoardLED 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Fusing Guide Board LED 1:ON(Active) 0:OFF(Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Main Unit Drawer LED 1:ON(Active)
  • Page 768 7. Input and Output Check Feed Mtr 1:Feed Speed1:Mid [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Feed Mtr 1:Feed Speed1:Mid- [0 or 1 / 0 / 1/step] Low Speed *D136 only This SP is only for D136 machine.
  • Page 769 Output Check Table Feed Mtr 2:Feed Speed2:Mid [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Feed Mtr 2:Feed Speed2:Mid- [0 or 1 / 0 / 1/step] Low Speed *D136 only This SP is only for D136 machine.
  • Page 770 7. Input and Output Check Feed Mtr 3:Feed Speed3:Mid [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Feed Mtr 3:Feed Speed3:Mid- [0 or 1 / 0 / 1/step] Low Speed *D136 only This SP is only for D136 machine.
  • Page 771 Output Check Table Feed Mtr 4:Feed Speed4:Mid [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Feed Mtr 4:Feed Speed4:Mid- [0 or 1 / 0 / 1/step] Low Speed *D136 only This SP is only for D136 machine.
  • Page 772 7. Input and Output Check Transport Mtr1:Feed Speed1:Mid [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Transport Mtr1:Feed Speed1:Mid- [0 or 1 / 0 / 1/step] Low Speed *D136 only This SP is only for D136 machine.
  • Page 773 Output Check Table Transport Mtr2:Feed Speed2:Mid [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Transport Mtr2:Feed Speed2:Mid- [0 or 1 / 0 / 1/step] Low Speed *D136 only This SP is only for D136 machine.
  • Page 774 7. Input and Output Check Transport Mtr3:Feed Speed3:Mid [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Transport Mtr3:Feed Speed3:Mid- [0 or 1 / 0 / 1/step] Low Speed *D136 only This SP is only for D136 machine.
  • Page 775 Output Check Table Transport Mtr4:Feed Speed4:Mid [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Transport Mtr4:Feed Speed4:Mid- [0 or 1 / 0 / 1/step] Low Speed *D136 only This SP is only for D136 machine.
  • Page 776 7. Input and Output Check Relay Mtr:CW:Feed Speed1:Mid [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Relay Mtr:CW:Feed Speed1:Mid- [0 or 1 / 0 / 1/step] Low Speed *D136 only This SP is only for D136 machine.
  • Page 777 Output Check Table Relay Mtr:CCW:Feed [0 or 1 / 0 / 1/step] Speed1:Mid Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Relay Mtr:CCW:Feed Speed1:Mid-Low Speed *D136 [0 or 1 / 0 / 1/step] only This SP is only for D136 machine.
  • Page 778 7. Input and Output Check Registration Mtr:Feed Speed1:Std [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Registration Mtr:Feed Speed1:Mid [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc.
  • Page 779 Output Check Table Registration Mtr:Position Hold [0 or 1 / 0 / 1/step] Stop Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Bypass Feed Mtr:Feed [0 or 1 / 0 / 1/step] Speed1:Std Speed Operates load for Motors and SOL etc.
  • Page 780 7. Input and Output Check Bypass Feed Mtr:Feed [0 or 1 / 0 / 1/step] Speed2:Low Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Inverter Ent Mtr:Exit Speed1:Std [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc.
  • Page 781 Output Check Table Inverter Ent Mtr:Exit Speed2:Low [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Exit/Inverter Mtr:CW:Exit [0 or 1 / 0 / 1/step] Speed1:Std Speed Operates load for Motors and SOL etc.
  • Page 782 7. Input and Output Check Exit/Inverter Mtr:CWW:Exit [0 or 1 / 0 / 1/step] Speed1:Low Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Exit/Inverter Mtr:CW:Exit [0 or 1 / 0 / 1/step] Speed2:Std Speed Operates load for Motors and SOL etc.
  • Page 783 Output Check Table Exit/Inverter Mtr:CWW:Exit [0 or 1 / 0 / 1/step] Speed2:Low Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Exit/Inverter Mtr: Position Hold [0 or 1 / 0 / 1/step] Operates load for Motors and SOL etc.
  • Page 784 7. Input and Output Check Duplex/Inverter Mtr:CW:Exit [0 or 1 / 0 / 1/step] Speed1:Std Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Duplex/Inverter Mtr:CW:Exit [0 or 1 / 0 / 1/step] Spd1:Mid Spd Operates load for Motors and SOL etc.
  • Page 785 Output Check Table Duplex/Inverter Mtr:Exit [0 or 1 / 0 / 1/step] Speed1:Std Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Duplex/Inverter Mtr:Exit [0 or 1 / 0 / 1/step] Speed1:Mid Speed Operates load for Motors and SOL etc.
  • Page 786 7. Input and Output Check Duplex/Inverter Mtr:Hold [0 or 1 / 0 / 1/step] Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Duplex Feed Mtr:Feed [0 or 1 / 0 / 1/step] Speed1:Std Speed Operates load for Motors and SOL etc.
  • Page 787 Output Check Table Duplex Feed Mtr:Feed [0 or 1 / 0 / 1/step] Speed2:Low Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Duplex Feed Mtr:Std Speed [0 or 1 / 0 / 1/step] Operates load for Motors and SOL etc.
  • Page 788 7. Input and Output Check Duplex Exit Mtr:Feed [0 or 1 / 0 / 1/step] Speed1::Low Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Duplex Exit Mtr:Feed Speed2::Std [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc.
  • Page 789 Output Check Table Duplex Exit Mtr:Feed Speed:Low [0 or 1 / 0 / 1/step] Speed Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Tray 1 Lift Motor: (Up: 1s) [0 or 1 / 0 / 1/step] Operates load for Motors and SOL etc.
  • Page 790 7. Input and Output Check Exit/Inverter JG SOL [0 or 1 / 0 / 1/step] Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Exit/Inverter JG SOL [0 or 1 / 0 / 1/step] Operates load for Motors and SOL etc.
  • Page 791 Output Check Table Shift Roller Motor2:Homing [0 or 1 / 0 / 1/step] Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON. Sensor Shift Motor:Std Speed [0 or 1 / 0 / 1/step] Operates load for Motors and SOL etc.
  • Page 792 7. Input and Output Check [0 or 1 / 0 / 1/step] Charge DC Voltage: C 1: ON (Active) 0: OFF (Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Charge DC Voltage: M 1: ON (Active) 0: OFF (Stop) Beware that long hours of operation may occur breakdown.
  • Page 793 Output Check Table [0 or 1 / 0 / 1/step] Development Bias: Bk 1: ON (Active) 0: OFF (Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Development Bias: C 1: ON (Active) 0: OFF (Stop) Beware that long hours of operation may occur breakdown.
  • Page 794 7. Input and Output Check [0 or 1 / 0 / 1/step] Primary Transfer :Y 1: ON (Active) 0: OFF (Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Secondary Transfer :+ 1: ON (Active) 0: OFF (Stop) Beware that long hours of operation may occur breakdown.
  • Page 795 Output Check Table [0 or 1 / 0 / 1/step] Refresh Roller Drive Motor:CW 1: ON (Active) 0: OFF (Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Refresh Roller Drive Motor:CCW 1: ON (Active) 0: OFF (Stop) Beware that long hours of operation may occur breakdown.
  • Page 796 7. Input and Output Check [0 or 1 / 0 / 1/step] Web Cleaning Drive Motor:CCW 1: ON (Active) 0: OFF (Stop) Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Decurl Cooling Fan 1: ON (Active) 0: OFF (Stop) Beware that long hours of operation may occur breakdown.
  • Page 797 Output Check Table [0 or 1 / 0 / 1/step] Decurl Transfer STM:MidLow Spd 1: ON (Active) *D136 only 0: OFF (Stop) This SP is only for D136 machine. Executing this SP on D135/D137/D138 machines may cause SC error. Beware that long hours of operation may occur breakdown. [0 or 1 / 0 / 1/step] Decurl Transfer STM:Low Spd 1: ON (Active)
  • Page 798 7. Input and Output Check [0 or 1 / 0 / 1/step] Bottom Plate Motor For/Rev 0:Off 1:On Executes driving ADF Bottom Plate Motor forward/in reverse and moves Bottom Plate up and down. [0 or 1 / 0 / 1/step] Stamp 0:Off 1:On...
  • Page 799 Output Check Table Exit Motor [0 or 1 / 0 / 1/step] Operates the specified motor for a certain period of time for operation check. Upper Junction Solenoid [0 or 1 / 0 / 1/step] Turns the specified Solenoid ON/OFF for operation check. TE Stack Plate Motor [0 or 1 / 0 / 1/step] Operates the specified motor for a certain period of time for operation check.
  • Page 800 7. Input and Output Check Corner Stapler Motor [0 or 1 / 0 / 1/step] Operates the specified motor for a certain period of time for operation check. Booklet Stapler Side Fence Motor [0 or 1 / 0 / 1/step] Operates the specified motor for a certain period of time for operation check.
  • Page 801 Output Check Table Shift Jogger Retraction Motor [0 or 1 / 0 / 1/step] Operates the specified motor for a certain period of time for operation check. Drag Roller Vibrating Motor [0 or 1 / 0 / 1/step] Operates the specified motor for a certain period of time for operation check. LE Guide Motor [0 or 1 / 0 / 1/step] Operates the specified motor for a certain period of time for operation check.
  • Page 802 7. Input and Output Check Stapler JG Mtr:Cont [0 or 1 / 0 / 1/step] OUTPUT Check for Stapler JG Motor (Continuous operation) Stp Hammer Moter:1 Op [0 or 1 / 0 / 1/step] OUTPUT Check for Stapler Hammer Motor (One operation) Feed Out M:1 Op [0 or 1 / 0 / 1/step] OUTPUT Check for Feed Out Motor (One operation)
  • Page 803 Output Check Table Return TransM:Cont [0 or 1 / 0 / 1/step] OUTPUT Check for Return Transport Motor (Continuous operation) Shift Jog Moter:1 Op [0 or 1 / 0 / 1/step] OUTPUT Check for Shift Jogger Motor (One operation) Shift Jog Shunt Moter:1 Op [0 or 1 / 0 / 1/step] OUTPUT Check for Shift Jogger Shunt Motor (One operation) Top Fence Motor:1 Op...
  • Page 804 7. Input and Output Check Turn Gate SOL1 [0 or 1 / 0 / 1/step] Turns the specified Solenoid ON/OFF for operation check. Turn Gate SOL2 [0 or 1 / 0 / 1/step] Turns the specified Solenoid ON/OFF for operation check. Turn Gate SOL3 [0 or 1 / 0 / 1/step] Turns the specified Solenoid ON/OFF for operation check.
  • Page 805 Output Check Table Tray Lift Motor:Down [0 or 1 / 0 / 1/step] OUTPUT Check operation for Tray Lift Motor (Down) Tray Lift Moter:1 Op [0 or 1 / 0 / 1/step] OUTPUT Check operation for Tray Lift Motor (One operation) [Output Check] 6310 OUTPUT Check operation.
  • Page 806 7. Input and Output Check 021 Bypass JG Solenoid [0 or 1 / 0 / 1/step] 022 Exit JG Solenoid [0 or 1 / 0 / 1/step] 023 Top Tray JG Solenoid [0 or 1 / 0 / 1/step] 024 LE Stop Pawl Solenoid [0 or 1 / 0 / 1/step] 025 Reverse JG Solenoid [0 or 1 / 0 / 1/step]...
  • Page 807: Printer Sp Mode

    8. Printer SP Mode SP1-XXX 1001 [Bit Switch] 001 Bit Switch 1 Settings bit 0 bit 1 bit 2 bit 3 No I/O Timeout Disabled Enabled Enables/Disables MFP I/O Timeouts. If enabled, the MFP I/O Timeout setting will have no affect. I/O Timeouts will never occur. bit 4 SD Card Save Mode Disabled...
  • Page 808 8. Printer SP Mode 002 Bit Switch 2 Settings bit 0 bit 1 bit 2 Applying a Collate Type Shift Collate Normal Collate A collate type (shift or normal) will be applied to all jobs that do not explicitly define a collate type.
  • Page 809 SP1-XXX 003 Bit Switch 3 Settings bit 0 bit 1 bit 2 [PCL5e/c]: Legacy HP compatibility Disabled Enabled Uses the same left margin as older HP models such as HP4000/HP8000. In other words, the left margin defined in the job (usually "<ESC>*r0A") will be changed to "<ESC>*r1A".
  • Page 810 8. Printer SP Mode Show "Collate Type", "Staple Type" and "Punch Disabled Enabled Type" buttons on the operation panel. If enabled, users will be able to configure a Collate Type, Staple Type, and Punch bit 0 Type from the operation panel. The available types will depend on the device and configured options.
  • Page 811 SP1-XXX bit 6 Method for determining the image rotation for the Disabled Enabled edge to bind on. If enabled, the image rotation will be performed as they were in the specifications of older models for the binding of pages of mixed orientation jobs. The old models are below: - PCL: Pre-04A models - PS/PDF/RPCS:Pre-05S models...
  • Page 812 8. Printer SP Mode bit 4 bit 5 bit 6 bit 7 1001 [Bit Switch] 008 Bit Switch 8 Settings bit 0 bit 1 bit 2 bit 3 Enabled (allow BW [PCL,PS]: Allow BW jobs to print without requiring Disabled jobs to print User Code without a user...
  • Page 813 SP1-XXX 009 Bit Switch 9 Settings bit 0 Disabled Enabled PDL Auto Detection timeout of jobs submitted via (Immediatel USB or Parallel Port (IEEE 1284). (10 seconds) To be used if PDL auto-detection fails. A failure of PDL auto-detection doesn't necessarily mean that the job can't be printed.
  • Page 814 8. Printer SP Mode bit 5 Display UTF-8 text in the operation panel Enabled Disabled Enabled (=0): Text composed of UTF-8 characters can be displayed in the operation panel. Disabled (=1): UTF-8 characters cannot be displayed in the operation panel. For example, job names are sometimes stored in the MIB using UTF-8 encoded characters.
  • Page 815 SP1-XXX bit 6 Allow use of Store and Skip Errored Job if Does not Allows SSEJ connected to an external charge device. allow SSEJ with ECD with ECD If this is 0, Store and Skip Errored Job (SSEJ) will be automatically disabled if an external charge device is connected.
  • Page 816 8. Printer SP Mode 1001 [Bit Switch] 012 Bit Switch C Settings bit 0 bit 1 bit 2 bit 3 bit 4 bit 5 bit 6 bit 7 1003 [Clear Setting] [- / - / -] Initialize Printer System *CTL [Execute] Initializes settings in the "System"...
  • Page 817 SP1-XXX [0 or 1 / 0 / 1 /step] 0:Link with Doc. Srv *CTL 1:Enable 0: Linked, 1: On Enables and disables the document server. When you select "0," the document server is enabled or disabled in accordance with Copy Service Mode SP5-967. When you select "1,"...
  • Page 818 8. Printer SP Mode 001 Color Gray Scale [ - / - / - ] [Execute] 002 Color Pattern [Gamma Adjustment] 1104 Adjusts the printer gamma for the mode selected in the "Mode Selection" menu. 001 Black: Highlight 002 Black: Shadow [0 to 30 / 0 / 1/step ] 003 Black: Middle 004 Black: IDmax...
  • Page 819 SP1-XXX [Toner Limit] 1106 Adjusts the maximum toner amount for image development. 001 Toner Limit Value *CTL [0 to 400 / 0 / 1 %/step ] [Media Print Device Setting] 1110 Selects the setting for the media print device. 002 0: Disable 1: Enable *CTL [0 or 1 / 1 / 1 / step] 1111...
  • Page 820 8. Printer SP Mode...
  • Page 821: Scanner Sp Mode

    9. Scanner SP Mode SP1-XXX [Scan Nv Version] 1001 Displays the scanner firmware version stored in NVRAM in a 9-digit format: Func. Name_Model Name_History No. 005 - *CTL [- / - / -] [Erase Margin(Remote scan)] Creates an erase margin for all edges of the scanned image. 1005 If the machine has scanned the edge of the original, create a margin.
  • Page 822 9. Scanner SP Mode [0 or 1 / 0 / 1 / step] *CTL 0: OFF (no display) 1: ON (count displays) This SP codes switches the original count display on/off. 1012 [User Info Release] [0 or 1 / 1 / 1 / step] *CTL 1: Release 0: Do not release...
  • Page 823 SP1-XXX *CTL * see BitSwitch below: Sets Scanner FlairAPI Function enable / disable. This SP is set by BitSwitch and needs to reboot the machine after making changes. meanings Setting Description Sets whether to start exclusive FlairAPI http server. If it is 0, scanning FlairAPI function and bit 0 Start of FlairAPI Server...
  • Page 824: Sp2-Xxx (Scanning-Image Quality)

    9. Scanner SP Mode SP2-XXX (Scanning-image quality) [Compression Level (Gray-scale)] 2021 Selects the compression ratio for grayscale processing mode (JPEG) for the five settings that can be selected at the operation panel. 001 Comp1:5-95 *CTL [5 to 95 / 20 / 1 / step] 002 Comp2:5-95 *CTL [5 to 95 / 40 / 1 / step]...
  • Page 825 SP2-XXX (Scanning-image quality) [BitSwitch] 9001 Sets module debug output mode. 001 cmm *CTL [0 to 255 / 0 / by a factor of two] 002 jcm *CTL [0 to 255 / 0 / by a factor of two] 003 ucm *CTL [0 to 255 / 0 / by a factor of two] 004 rsp...
  • Page 826 9. Scanner SP Mode...
  • Page 827: Software Version Up

    10. Software Version up Software Update Software Update Procedure SD cards are used to update the software and to back up important data. Here is a list of the firmware modules that can be updated or restored from an SD card: •...
  • Page 828 10. Software Version up 3. Hold the SD card (the surface with printing must be away from the front of the machine), and install the SD card in slot 2 [A]. 4. Turn the main power switch on. 5. Stop until the version update screen is displayed. If the SD card contains more than one software application, the screen will be almost the same as the one below.
  • Page 829 Software Update • If you push [Exit] (or the [0] key), you go back to the usual operation screen. • Push the [Start] key on the operation panel to select and download all the options shown on the screen. • Push the [Clear] key on the operation panel if you want to cancel your selections and make new ones.
  • Page 830 10. Software Version up After the firmware update, you will see "Update Done" in the first bar. The name of the module in the bottom bar is the name of the last module that was updated (only the name of the last module is shown, if several modules were been updated).
  • Page 831: Errors During Firmware Update

    Software Update Errors During Firmware Update If an error occurs during a download, an error message will appear. The error code consists of the letter "E" and a number ("E20", for example). Error Message Table meaning Solution Make sure the SD card is installed correctly, or use a Cannot map logical address different SD card.
  • Page 832: Updating The Lcdc For The Operation Panel

    10. Software Version up Module mismatch - Correct The data on the SD is not correct. Get the correct data module is not on the SD card (Japan, Overseas, OEM, etc.) then install again. SD update data is not correct. The data on the SD card is Module mismatch –...
  • Page 833: Downloading Stamp Data

    Software Update Downloading Stamp Data After you replace or format the HDD, download the stamp data from the controller firmware to the hard disk. 1. Go into the SP mode. 2. Select SP5853 then press "Execute". 3. Obey the instructions on the screen to complete the procedure.
  • Page 834: Updating Java Vm

    10. Software Version up Updating Java VM Creating an SD Card for Updating 1. Download the update modules from Firmware Download Center. As one of the model modules, "Java VM v11 UpdateTool" is available for download. (The version differs depending on the model.) 2.
  • Page 835: List Of Error Messages

    Updating Java VM 4. When the update is complete, "Update SDK / J done SUCCESS" will appear in the banner message of the touch panel display. After turning off the power, remove the SD card from the slot. When you fail to update, "Update SDK/J done FAIL" is displayed. You can confirm the cause of the error message below.
  • Page 836 10. Software Version up Error Message Cause Remedy PIECEMARK Applied the wrong updating Use the correct updating tool for tool (Using the updating tool of this model. Error,machine=XXXXX a different model) pasePut() - error : The file of the Inadequacy with the SD card Re-create the SD card for for updating updating.
  • Page 837 Updating Java VM Error Message Cause Remedy Put Error! *1 Error, not normally expected to If you cannot uninstall it, occur implement escalation stating the Copy Error! *1 "model name, application configuration, SMC sheet Delete Error! (SP5-990-006/024/025), [XXXXX] is an unsupported and error file."...
  • Page 838: Updating The Exjs

    10. Software Version up Updating the EXJS To Update EXJS 1. Turn the main switch ON. 2. D135/D136: Press the “User Tools/Counter” key. D137/D138: Press the “User Tools” key. 3. On the touch panel, touch “Extended Feature settings”. 4. Touch “Extended Feature settings” in the Extended Feature Settings Menu. 5.
  • Page 839 Updating the EXJS 9. Turn the main switch ON. 10. After the Update screen is displayed, select the “Browser”. 11. Touch “Update (#)”. 12. After the "Update Done" message appears on the screen, turn the main power switch OFF. 13. Remove the SD card from the lower slot. Do the following steps if you are updating the Extended JavaScript (EXJS).
  • Page 840: When Checking The Version Of Exjs

    10. Software Version up 18. Touch “Extended Feature settings” in the Extended Feature Settings Menu. 19. Change the status of “Extended JS” to “Ending” in the Startup Settings tab. 20. Turn the main switch OFF. 21. Insert the SD card containing the Extended JS firmware into the lower slot. 22.
  • Page 841 Updating the EXJS 5. Check the version of “Extended JS” on the “Startup Settings” tab is the latest version. • If checked apart from the above procedure (firmware version displayed in system default settings), a different version from the actual version may be displayed.
  • Page 842: Package Firmware Update (D135/D136 Only)

    10. Software Version up Package Firmware Update (D135/D136 only) Also see D135 RTB 65 Overview Each firmware module (such as System/Copy, Engine, etc) used to be updated individually. However, an all-inclusive firmware package (package_ALL) is now available. There are two ways to update using the firmware package. •...
  • Page 843: Immediate Update

    Package Firmware Update (D135/D136 only) Types of firmware update files, supported update methods: Individual firmware Available Available Package firmware Available Available Immediate Update Enter the [Firmware Update] menu from the SP mode and update the package firmware. • The [Firmware Update] button will appear even when a machine is connected to @Remote with a device which does not have an embedded @Remote communicating function.
  • Page 844 10. Software Version up Touch [Firmware Update]. Touch [Update]. Touch [Execute Update].
  • Page 845 Package Firmware Update (D135/D136 only) Touch [YES]. The following display will be displayed. • If the error code E66, which indicates that the download of the firmware has failed, is displayed, implement this procedure from the step1. • Update will be started automatically after the download is finished. •...
  • Page 846: Update At The Next Visit (Reserve)

    10. Software Version up After the message [Update done] is displayed, the machine will automatically reboot itself. • The figures at the lower right of the display indicate “Number of items updated/All items to be updated”. Update at the Next Visit (Reserve) It is possible to set the machine to download the package firmware which is necessary for SFU in advance, and then perform the actual installation at the next service visit.
  • Page 847: How To Set The Machine To Download Firmware Later (Reserve)

    Package Firmware Update (D135/D136 only) How to Set the Machine to Download Firmware Later (RESERVE) Enter the [Firmware Update] menu from the SP mode and update the package firmware. • The [Firmware Update] button will appear even when a machine is connected to @Remote with a device which does not have an embedded @Remote communicating function.
  • Page 848 10. Software Version up Touch [Reserve]. Touch [Reservation setting]. Enter the dates and times of next visit and start of receiving data. • ”Next time to visit this customer”: The package firmware will be automatically downloaded by this time/date. • ”When to receive? (1-7)”: The download of the package firmware will begin this number of days before the next visit.
  • Page 849 Package Firmware Update (D135/D136 only) Successful Download In the two diagrams below, the firmware was set to be downloaded by the day before the next scheduled visit. In the first diagram, the download was successful on the first try. In the second diagram, the download failed three times and was successful on the fourth try.
  • Page 850: How To Check If The Firmware Downloaded With Reserve

    10. Software Version up • If the download cannot be completed successfully by the time of the next scheduled visit, the machine will stop trying to download the firmware. How to Check if the Firmware Downloaded with RESERVE Enter the SP mode. Touch [Firmware Update].
  • Page 851: How To Install Firmware Downloaded With Reserve

    Package Firmware Update (D135/D136 only) Touch [Reserve and received package information]. Check the information displayed. When the package firmware is downloaded successfully, the details of the download result are displayed as the following picture shows. • This information will only be displayed if the reserved firmware has already been downloaded.
  • Page 852 10. Software Version up Touch [Firmware Update]. Touch [Update]. Touch [Execute Update].
  • Page 853 Package Firmware Update (D135/D136 only) Check the version of the received package firmware and touch [YES]. Then update is started. • If the version of the reserved package in the HDD is older than the latest version, the massages shown in the following picture are displayed. •...
  • Page 854: Update Via Sd Card

    10. Software Version up After the [Update done] message is displayed, the machine will automatically reboot itself. • The figures at the lower right of the display indicate “Number of items updated/All items to be updated”. Update via SD card Update with an SD card, which is the conventional method, is performable if you write the package firmware to the SD card.
  • Page 855 Package Firmware Update (D135/D136 only) Create a new folder inside the SD card and name it “package”. Then copy the package firmware (xxxxxxxx.pkg) to this folder. • If you copy the package firmware into the conventional “romdata” folder, the update will not work.
  • Page 856 10. Software Version up After the package firmware download to the HDD is completed, update is stared automatically. When update is completed, “Update done” is displayed. • The figures at the lower right of the display indicate “Number of items updated/All items to be updated”.
  • Page 857: Nvram Data Upload/Download

    11. NVRAM Data Upload/Download Uploading Content of NVRAM to an SD card Do the following procedure to upload SP code settings from NVRAM to an SD card. • This data should always be uploaded to an SD card before the NVRAM is replaced. •...
  • Page 858 11. NVRAM Data Upload/Download NVRAM\<serial number>.NV Here is an example with Serial Number “K5000017114”: NVRAM\K5000017114.NV 7. In order to prevent an error during the download, be sure to mark the SD card that holds the uploaded data with the number of the machine from which the data was uploaded. •...
  • Page 859: Downloading An Sd Card To Nvram

    Downloading an SD Card to NVRAM Downloading an SD Card to NVRAM Do the following procedure to download SP data from an SD card to the NVRAM in the machine. • The NVRAM data down load may fail if the SD card with the NVRAM data is damaged, or if the connection between the controller and BCU is defective.
  • Page 860 11. NVRAM Data Upload/Download • The serial number of the file on the SD card must match the serial number of the machine for the NVRAM data to download successfully. The download fails if the serial numbers do not match. This procedure does not download the following data to the NVRAM: •...
  • Page 861: Address Book Upload/Download

    12. Address Book Upload/Download Information List The following information is possible to be uploaded and downloaded. • Registration No. • User Code • E-mail • Protection Code • Fax Destination • Fax Option • Group Name • Key Display • Select Title •...
  • Page 862: Download

    12. Address Book Upload/Download Download 1. Prepare a formatted SD card. 2. Make sure that the write-protection on the SD card is off. 3. Turn off the main power switch of the main machine. 4. Remove the SD slot cover [A] ( x 1). 5.
  • Page 863 Download • Carefully handle the SD card, which contains user information. Do not take it back to your location.
  • Page 864: Upload

    12. Address Book Upload/Download Upload 1. Turn off the main power switch of the main machine. 2. Remove the SD slot cover [A] ( x 1). 3. Install the SD card, which has already been uploaded, into the SD card slot 2 [A]. 4.
  • Page 865: Capturing Log To Sd Card

    13. Capturing Log to SD card Overview Also see RTB 29 With this feature, you can save debug logs that are stored in the machine (HDD or operation panel) on an SD card. It allows the Customer Engineer to save and retrieve error information for analysis. The Capturing Log feature saves debug logs for the following three.
  • Page 866: Security Of The Operation Log

    13. Capturing Log to SD card Type Storage Timing Destination (maximum storage capacity) Operation • When a controller SC occurs Operation panel (400 MB /Up to panel debug 30 times) • When saving by manual operation with the Number keys and the Reset When updating the firmware for the key (Press “Reset”, “0”, "1”...
  • Page 867: Retrieving The Debug Logs

    Retrieving the Debug Logs Retrieving the Debug Logs • Retrieve debug logs to identify the date of occurrence of the problems and to find details of the problems • e.g.: At around 8:00 am on March 10, an engine stall occurred. The operation panel does not respond.
  • Page 868 13. Capturing Log to SD card • The approximate time it takes to transfer the debug log is as follows. Transfer time may be affected by the type or format of the SD card. (It is recommended that you format the SD card using the Panasonic SD Formatter (freeware)).
  • Page 869 MEMO...
  • Page 870 MEMO paper...

Table of Contents