Steps
1. Go to Configuration → VCA → Camera 01/Camera 02 → Basic Settings → Polling Plan .
2. Select a polling mode.
Auto
The device automatically activates the optical channel for perimeter protection in
daytime and the thermal channel at night.
Manual You can manually set the working shifts for the channels.
a. Select the Polling Mode as Manual.
b. Select Optical Channel or Thermal Channel for the drop-down list.
c. Drag to draw time bars on the schedule. Click on the drawn bar to adjust the
time and the channel.
The schedule for the channels cannot overlap.
3. Click Save.

6.4 Advanced Configuration

Go to Configuration → VCA → Advanced Configuration and configure the parameters.
Detection Parameters
Single Alarm
The system only sends alarm once for one target triggering. Otherwise, the alarm will be
triggered continuously until the target disappears.
Scene Modes
The scene mode is set to be General by default. Select Distant View when you are far from the
targets. Select Leaves Interfered View when there are shaking targets in the scene, such as
leaves.
Tracking Parameters
Post-tracking
Set the duration of automatic tracking of the target after it stops. E.g., set post-tracking duration
to 10s, the camera tracks the target until that it stop and has been still for over 10s.
Back to Scene Time
Set the duration of the camera moving back to original scene after perimeter protection is
started.
Restore Parameters
Restore Default
Click Restore to restore the parameters to the default.
Restart VCA
Note