Preliminary Steps; Removing The Bbu With The Holder - Fujitsu PRIMERGY TX150 S8 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX150 S8:
Table of Contents

Advertisement

Expansion cards and backup units
9.5.4.1

Preliminary steps

"Disabling SVOM boot watchdog functionality" on page 80
Ê
"Shutting down the server" on page 50
Ê
"Disconnecting the server from the mains" on page 50
Ê
"Getting access to the component" on page 51
Ê
9.5.4.2

Removing the BBU with the holder

Figure 161: Removing the BBU holder from the chassis
Ê Carefully disconnect the BBU cable from the RAID controller (1).
Ê Lift up the green locking handle on the BBU holder (2, see close-up) while
sliding the BBU holder in the direction of the arrow as far as it will go (3).
I
After that, the hooks on the air duct will rest in the wide ends of the
keyhole slots on the holder.
Ê Lift the BBU holder out of the chassis.
234
Upgrade and Maintenance Manual
TX150 S8 / TX200 S7