Basic software procedures
Resetting the boot retry counter using the ServerView Operations
Manager
Ê In the ServerView Operations Manager Administration view, select Server
Configuration.
Ê If more than one server is managed in SVOM, select the target server and
click Next.
Ê From the Server Configuration menu pane, choose Restart Options.
Ê Under Reboot Retries, specify the maximum number of boot attempts (0 to 7)
in the Default for reboot tries field.
Resetting the boot retry counter using iRMC web frontend
Ê Enter the ServerView iRMC web frontend.
Ê Select the Server Management menu.
Ê The following boot retry counter settings are available under ASR&R Options:
Ê Under Retry counter max specify the maximum number of attempts to boot
the operating system (0 to 7).
Ê Under Retry counter the current number of remaining boot attempts is
displayed. Overwrite this value with the maximum number of boot
attempts specified above in order to reset the boot retry counter.
Ê Click Apply for the changes to take effect.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
5.2.7

Enabling SVOM boot watchdog functionality

If ServerView Operations Manager boot watchdog functionality has been
disabled for firmware upgrade purposes (see section
to be re-enabled to complete the maintenance task.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web frontend:
Configuring boot watchdog settings in the BIOS
Ê Enter the BIOS.