Replacing An Fbu; Preliminary Steps; Removing The Defective Fbu - Fujitsu PRIMERGY TX150 S8 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX150 S8:
Table of Contents

Advertisement

Ê If the BBU is shown as bad or defective, do not power off the server for at
least 8 hours to allow the charge and calibration cycles to finish.
Ê If the BBU status does not change after 8 hours, please try to initiate the
recalibration process manually using the ServerView RAID Manager.
I
If this procedure still does not fix the BBU status, please contact your
local Fujitsu customer service partner.
9.5.7

Replacing an FBU

Upgrade and Repair Unit
(URU)
Tools: tool-less
V
CAUTION!
Do not throw battery FBUs into the trash can. Batteries must be disposed
of in accordance with local regulations concerning special waste.
For further safety information, please refer to section
protection" on page
9.5.7.1

Preliminary steps

"Locating the defective server" on page 47
Ê
"Disabling SVOM boot watchdog functionality" on page 80
Ê
"Shutting down the server" on page 50
Ê
"Disconnecting the server from the mains" on page 50
Ê
"Getting access to the component" on page 51
Ê
9.5.7.2

Removing the defective FBU

Ê Remove the FBU with the holder as described in section
with the holder" on page
Ê Disconnect the FBU cable from the FBU as described in section
"Disconnecting the FBU cable from the FBU" on page
TX150 S8 / TX200 S7
44.
237.
Upgrade and Maintenance Manual
Expansion cards and backup units
Hardware: 10 minutes
"Removing the FBU
238.
"Environmental
241