Processors
11.3

Removing processors

Upgrade and Repair Unit
(URU)
Tools: Phillips PH2 / (+) No. 2 screw driver
V
CAUTION!
Processors are extremely sensitive to electrostatic discharge and must
be handled with care. After a processor has been removed from its
protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.

11.3.1 Preliminary steps

"Disabling or suspending BitLocker functionality" on page 79
Ê
"Disabling SVOM boot watchdog functionality" on page 80
Ê
"Shutting down the server" on page 50
Ê
"Disconnecting the server from the mains" on page 50
Ê
"Getting access to the component" on page 51
Ê
"Removing processor heat sinks" on page 270
Ê

11.3.2 Removing a processor

I
This description applies to the following procedures:
– Removing the second processor (CPU 2) from a dual-processor
configuration
– Removing processors from a defective system board (see section
"Replacing the system board" on page
Ê Remove the desired processor heat sink as described in section
processor heat sinks" on page
260
270.
Upgrade and Maintenance Manual
Hardware: 15 minutes
Software: 5 minutes
375)
TX150 S8 / TX200 S7
"Removing