If you do not know why the CSMIM-T1 booted the wrong image, enter
the ROM Monitor mode and issue an image -d command. The command
display will list the image file the CSMIM-T1 is trying to load.
5.2.2

SET UP Mode

Enter SET UP Mode by pressing the SET UP
CSMIM-T1 front panel. Press this button within 30 seconds of resetting
or powering up the device.
5.2.2.1

SETUP Mode Error-Free Sequence

Table 5-4 summarizes the LED sequences that display in test mode during
an error-free start-up. A description of each sequence follows Table 5-4.
Activity
T1: Testing Indicators
T2: Testing Hardware
T3: At Monitor Prompt
Key:
On continuously.
Off.
Flashing irregularly.
Flashing regularly (about 1Hz).
Activity T1: Testing Indicators
All front panel indicators light for a few seconds, then all but the Ethernet
channel indicator turn off. This sequence confirms that all indicators are
operational. At this point, the CSMIM-T1 is in normal mode. Press the
SET UP button to put the CSMIM-T1 into ROM monitor mode.
CSMIM-T1 Hardware Installation Guide
Table 5-4 Normal Mode Error LED States
Power-Up and Boot Procedures
button
STAT
ATTN
Green
Amber
located on the
TRAF
Green
5-7