Chapter 5: Troubleshooting Procedures
Error
Msgs with wrong size
ERPC layer errors
Aborts rx'd
Error
ARP errors
ERPC layer errors
Aborts rx'd
5-12
Table 5-7 Errors from Last Read Request
Description
The correct host responded to the Read Request, but
the data size is incorrect.
See
Table
The host's BFS transmitted an abort in response to the
CSMIM-T1's Read Request. Run erpcd –D on the host
to obtain more information.
Table 5-8 Errors from Last Open Request
Description
Address Resolution Protocol (ARP) errors indicate that the
CSMIM-T1 is configured to boot from a specified host, but
the host would not transmit its Ethernet address to the
CSMIM-T1. Possibly, the CSMIM-T1 configuration
includes the wrong IP encapsulation.
See
Table 5-6
The host's BFS transmitted an abort in response to the
CSMIM-T1's Open Request. This often means that the
requested file does not exist on that server. Run erpcd –D
on the host to obtain more information.
5-6.