tni_line_code
tni_ones_density
tdi_distance
tdi_framing
tdi_line_code
4.4

PARAMETER DESCRIPTIONS

The CSMIM-T1 software comes with the following new parameters:
alarmsyslog
This T-1 parameter enables or disables the T-1 alarm event syslogs. A Y
enables this parameter, an N disables it. The default is Y.
bypass
This T-1 parameter is used to remove the T-1 engine from the network.
When bypass is set to Y, the T1 engine is off-line and the T1 Network
Interface (T1NI) and the T1 Drop and Insert Interface (T1DII) are
physically isolated from the T-1 engine. When bypass is set to Y, the T-1
engine has no effect on the T-1 circuit. When bypass is set to N, the T-1
engine is attached to both the T1NI and the T1DII. The default is Y.
CSMIM-T1 Hardware Installation Guide
Sets or displays parameter setting as ami or b8zs. These
values represent the line code used on the T1 Network
Interface.
Sets or displays the T1 Network Interface ones density
setting as on or off.
Sets or displays an integer from 0 to 655 that represents
the length of the cable from the T1 Drop/Insert Interface to
the PBX or other equipment.
Sets or displays the superframe format used on the T1
Drop/Insert Interface as d4 (superframe) or esf (extended
superframe). The default is esf.
Sets or displays the T1 Drop/Insert Interface line code
setting as either ami or b8zs. The default is b8zs.