Vax Vms Load Host On The Lan - Cabletron Systems CSMIM-T1 Installation Manual

Enterasys csmim-t1 communication server: install guide
Hide thumbs Also See for CSMIM-T1:
Table of Contents

Advertisement

Chapter 5: Troubleshooting Procedures
5.3.2.4

VAX VMS Load Host on the LAN

If the installation was successful and the NCP CIRCUIT SERVICE is
enabled, but the CSMIM-T1 still fails to boot, performing the following
steps may locate your problem:
1.
Make sure that the file CSMIM-T1 OPER_46_ENET.SYS is in the
directory MOM$LOAD and the file protection allows reading.
2.
Enter the system manager account and enable console logging to see
the MOP boot requests, as in the following example:
$reply/enable
$
%%%%%%%% OPCOM 23-DEC-1994 08:3.37 %%%%%%%%
Operator_NTA2: has been enabled, username TOPAZ
$
$
%%%%%%%% OPCOM 23-DEC-1994 08:0.49 %%%%%%%%
Operator status for operator _NTA2:
CENTRAL, PRINTER, TAPES, DISKS, DEVICES, CARDS, NETWORK,
CLUSTER, SECURITY, LICENSE, OPER1, OPER2, OPER3, OPER4,
OPER5, OPER6, OPER7, OPER8, OPER9, OPER10, OPER11, OPER12
W
$
ARNING
$
%%%%%%%% opcom 23-DEC-1994 08:03:43.55 %%%%%%%%
Message from user DECNET
DECnet event 0.3, automatic line service
From node 1.69 (BINGO), 23-DEC-1994 08.03.43.52
Circuit SVA-0, Load, requested, Node =2.69 (BART)
File = MOM$SYSTEM_SOFTID:OPER_46_ENET.SYS, Operating
System
Ethernet address = 00-80-2D-00-1A-DE
$
%%%%%%%% opcom 23-DEC-1994 08:03:50.55 %%%%%%%%
Message from user DECNET
DECnet event 0.3, automatic line service
From node 1.69 (BINGO), 23-DEC-1994 08.03.50.52
Circuit SVA-0, Load, Successful, Node =2.69 (BART)
File = MOM$SYSTEM_SOFTID:OPER_46_ENET.SYS, Operating
System
Ethernet address = 00-80-2D-00-1A-DE
5-16
CSMIM-T1 Hardware Installation Guide

Advertisement

Table of Contents
loading

Table of Contents