T-1 Parameters - Cabletron Systems CSMIM-T1 Installation Manual

Enterasys csmim-t1 communication server: install guide
Hide thumbs Also See for CSMIM-T1:
Table of Contents

Advertisement

Chapter 4: CSMIM-T1 Parameters
4.3

T-1 PARAMETERS

The CSMIM-T1 software comes with the following new T-1 parameters:
Keyword
alarmsyslog
bypass
map
ring
sigproto
t1_info
tni_circuit_id
tni_clock
tni_esf_fdl
tni_framing
tni_line_buildout
4-8
Sets or displays parameter setting as yes or no. These
values enable or disable the alarm event syslogs.
Sets or displays parameter setting as yes or no. A setting
of yes removes the T-1 engine from the network.
Sets or displays mappings for the DS0 channels.
Sets or displays parameter setting as yes or no. A setting
of yes means that an audible ring is sent to the service
provider for incoming calls.
Sets or displays the inbound and outbound signaling
protocol settings for each DS0 channel.
Sets or displays a character string (128 bytes maximum)
of printable ASCII characters that describe installation
information from the service provider.
Sets or displays the T-1 circuit identifier string (128
characters maximum) required by the service provider for
customer service calls.
Sets or displays parameter setting as loop, local, or
external. These values represent the source for the T-1
clock.
Sets or displays parameter setting as ansi or att. These
values represent the Facilities Data Link standard.
Sets or displays parameter setting as d4 or esf. These
values represent the superframe format setting on the T1
Network Interface.
Sets or displays parameter setting as 0, 7.5, 15, or 22.5.
These values represent the cable loss measurement
between the last line generator and the customer location.