Chapter 3: ROM Monitor Commands
The addr command display looks like this:
monitor:: addr
Enter Internet address [<uninitialized>]:: 192.9.200.214
Enter Subnet mask [255.255.0.0]::
Enter Broadcast address [0.0.0.0]:: 192.9.200.0
Enter Preferred Load Host address [<any host>]:: 192.9.200.88
Enter Preferred Dump Host address [0.0.0.0]:: 192.9.200.88
Enter Load/Dump Gateway address [<uninitialized>]:: 192.9.200.
Select type of IP packet encapsulation (ieee802/ethernet)
[<ethernet>]::
Load Broadcast Y/N [Y]::
The addr -d command display looks like this:
monitor:: addr -d
Ethernet address (hex): 00-80-2D-00-C6-1E
Internet address: 192.9.200.214
Subnet mask: 255.255.0.0
Broadcast address: 192.9.200.0
Preferred Load Host address: 192.9.200.88
Preferred Dump Host address: 192.9.200.88
Load/Dump Gateway address: 192.9.200.10
Type of IP packet encapsulation: <ethernet>
Load Broadcast: Y
The CSMIM-T1 must have an Internet (IP) address in its memory before
it can load its operational image across the Ethernet via the IP protocol.
Therefore, you must enter the IP address before booting the CSMIM-T1
from a UNIX load host. If you do not define an IP address for the Remote
Annex, it will attempt to learn the address using BOOTP or RARP. If you
3-4
Internet address: 192.9.200.214
Broadcast address: 192.9.200.0
Preferred Load Host address: 192.9.200.88
Preferred Dump Host address: 192.9.200.88
Load/Dump Gateway address: 192.9.200.88
CSMIM-T1 Hardware Installation Guide