Activity TE2: Hardware Failure
The ROM diagnostics detected a CSMIM-T1 hardware problem requiring
service. Call Technical Support.
Activity TE7: Booted Wrong Image
The CSMIM-T1 loaded an inappropriate image. Press the SETUP button
for three seconds to reset the device. Following is a list of ways to prevent
this problem in the future:
Be sure that you configure the CSMIM-T1 with the appropriate image
(
oper.46.enet
Be sure that the image you are booting has the right name. Don't
rename the image file unless you are making a copy for safe keeping.
If you used an na, admin, or cli boot command, specify the correct
image and a valid filename.
5.3

BOOT FAILURES

The procedures for troubleshooting a power-up failure established that
The hardware is functional.
The Ethernet interface is functional.
The CSMIM-T1 can communicate with the Ethernet.
If the CSMIM-T1 still is not booted, you must pinpoint the problem. The
boot error report can help in this process.
The CSMIM-T1generates a boot error report only if it opens the
NOTE
boot file and an error occurs during the boot process.
Generally, two problems cause boot failures:
The CSMIM-T1 is not configured properly.
The load server host is not responding.
CSMIM-T1 Hardware Installation Guide
).
BOOT Failures
5-9