Cabletron Systems CBUPRI/E1 User Manual

Enterasys cbupri/e1 interface modules: user guide

Advertisement

Quick Links

CBUPRI/E1
SBUPRI-23/30

User Manual

Fivemere Ltd.
Unit 1, Heron Industrial Estate
Basingstoke Road
Spencers Wood
Reading, Berks
RG7 1PJ
Telephone: [44] (0) 118 988 0082
Fax:
[44] (0) 118 988 0081

Advertisement

Table of Contents
loading

Summary of Contents for Cabletron Systems CBUPRI/E1

  • Page 1: User Manual

    CBUPRI/E1 SBUPRI-23/30 User Manual Fivemere Ltd. Unit 1, Heron Industrial Estate Basingstoke Road Spencers Wood Reading, Berks RG7 1PJ Telephone: [44] (0) 118 988 0082 Fax: [44] (0) 118 988 0081...
  • Page 2 CBUPRI/E1 SBUPRI-23/30 User Manual Publication — 80-14005000-01 Publication Notice: This manual has been compiled and checked for accuracy. However the information contained in this manual does not constitute a warranty of performance. Fivemere Ltd. reserves the right to revise this publication from time to time without notice.
  • Page 3 History Sheet 80-14000000-01 V1.00 Software 80-14000000-02 Cabletron Systems Edition 80-14005000-01 Addition of SBUPRI-23 and SBUPRI-30 80-14005000-01 CBUPRI/E1 SBUPRI-23/30 User Manual 24 June 1996 01 July 1997 15 April 1999...
  • Page 4: Table Of Contents

    CBUPRI/E1 SBUPRI-23/30 User Manual TABLE OF CONTENTS THE PRIMARY RATE SYSTEM NTRODUCTION HIS IS THE RIMARY RIMARY NTERFACE (SBUGSM HELF ANAGER ODULE ODULES 1.5.1 PEED ODULE 1.5.2 PEED ODULE THE PRIMARY RATE INTERFACE MODULE NTRODUCTION RONT AND EAR CARDS HELF...
  • Page 5 NITED INGDOM AND UROPE USA C OMPLIANCE FOR 4.2.1 FCC R ULES 4.2.2 FCC R ULES 4.2.2.1 FCC P 68 R EGISTRATION 4.2.2.2 ERVICE 4.2.2.3 ACILITY NTERFACE NFORMATION 4.2.2.4 ISRUPTION OF THE ETWORK 4.2.2.5 ELEPHONE OMPANY 4.2.2.6 LECTRICAL AFETY GLOSSARY OF TERMS 80-14005000-01 TABLE OF CONTENTS NDUSTRY...
  • Page 6: The Primary Rate System

    The Primary Rate system 1.1 Introduction This manual has been written to provide users of the Primary Rate system with all the necessary information to configure and operate the system. This chapter provides a brief introduction to the system and it’s components.
  • Page 7 CBUPRI/E1 SBUPRI-23/30 User Manual CBUPRI/E1 - this is the first iteration, providing 2.048Mbit/s ‘E1’ type ISDN access SBUPRI-30 - the later version with the same features as CBUPRI/E1, but with capacity for future expansion SBUPRI-23 - as for SBUPRI-30 but is a 1.544Mbit/s ‘T1’ ISDN access version for the USA market.
  • Page 8: The Primary Rate Interface Module

    30 ‘B’ channels (23 for USA) for use by other application cards in the Primary Rate system. The CBUPRI/E1 and SBUPRI-30 works with ‘Euro’ Primary Rate (I.421) ISDN. The SBUPRI-23 works with US National standard (Bellcore NI-2). All 3 types have a physical interface provided by an RJ45 connector.
  • Page 9: Quad High Speed Module (Sbuqhs/Sbuqhb)

    CBUPRI/E1 SBUPRI-23/30 User Manual 1.5.2 Quad High Speed Module (SBUQHS/SBUQHB) The SBUQHS provides four User ports per card offering N x 64k data rates on each port, with X.21 and V.35 interfaces. The interfaces are chosen by selection of the desired type of interface card for all four ports.
  • Page 10: The Primary Rate Interface Module

    Module. The front card carries out the call processing functions, the rear card carries the line matching/isolating transformers. cards are not interchangeable between the CBUPRI/E1 and SBUPRI- 23/30 modules. 2.2 Front and Rear cards The panel layouts for the front and rear cards that make up the SBUPRI...
  • Page 11 CBUPRI/E1 SBUPRI-23/30 User Manual Ch. in Use ISDN Layer 2 RAI/Yellow AIS/Blue M aster Ale rt Front Figure 1 SBUPRI front and rear panels 2–2 & ISDN PRI R ear 80-14005000-01...
  • Page 12: Shelf Power Loading

    The SBUPRI provides up to 30 x 64kbit/s ‘B’ channels (23 for USA), each channel can be switched to any time-slot on any of the four 2.048 Mbit/s backplane buses. The SBUPRI will provide on demand individual 64 kbit/s channels for use by other application cards in the shelf.
  • Page 13: Switches And Jumpers

    CBUPRI/E1 SBUPRI-23/30 User Manual 2.4 Switches and Jumpers All switches and jumpers must only be changed by a competent engineer. 2.4.1 8 Way DIL Switch Setting CBUPRI/E1 & SBUPRI-30 Pole 1 Reserved (F) Multiframe ISDN Pole 2 Operation - CRC4...
  • Page 14: Sbupri-23 T1 Product Variant - Poles

    2.4.1.1 SBUPRI E1 Product Variant - Poles 5-7 Variant Country Variant 0 Euro ISDN. UK and most European countries: Variant 2 Euro ISDN*. France and Sweden: Variant 3 ‘Channel ID’ element not presented*. Sweden: *NOTE: Variants 2 and 3 do not have single octet information elements present in the call setup message.
  • Page 15: Cbupri/E1 Front Card Jumpers And Links

    CBUPRI/E1 SBUPRI-23/30 User Manual 2.4.2 CBUPRI/E1 Front Card Jumpers and Links These are all factory set and must not be changed, and are effective at Issue 03 hardware. (See section jumpers). Jumper Links R65, R66, R67 Link R72 Link R73...
  • Page 16: Sbupri-2330 Front Card Jumpers And Links

    2.4.3 SBUPRI-2330 Front Card Jumpers and Links These are all factory set and must not be changed. Jumper OUT (F) OUT (F) JP12 OUT (F) 2.4.4 SBUPRI-2330 Rear Card Jumpers and Links These are all factory set and must not be changed. Jumper JP1, JP7-JP13 JP2 - JP6...
  • Page 17: Physical Pri Error Conditions

    CBUPRI/E1 SBUPRI-23/30 User Manual 2.5.1 Physical PRI Error conditions AIS/Blue received (Alarm Indication Signal - from local NT) RAI/Yellow received (Remote Alarm Indication - from remote NT) RED Loss of Frame Alignment RED Loss of signal Detection of CRC Errors The last three are all locally sensed conditions from the NT.
  • Page 18: Major Equipment Failure

    Master clocking from the ISDN is supplied by the module to the shelf system (SBUPRI- 23 and SBUPRI-30 only) When there are outstanding ALERTs on the SBUPRI not yet received by the Shelf Manager Module (The CBUPRI/E1 can only support 2–9...
  • Page 19: Management And Control

    CBUPRI/E1 SBUPRI-23/30 User Manual The PRI is connected via a screened RJ-45 connector and provides a correctly terminated 100/120 up to 4m of category 4 STP cable. The pin connections for the 8-way RJ45 socket on all SBUPRI are shown...
  • Page 20: Sbupri Command Menu

    SBUPRI Command Menu The SBUPRI uses a command menu structure similar to other Fivemere products. Some menu options are marked with an asterisk (*) to indicate that they are unavailable - this is to maintain the overall menu structure across the product range. menus.
  • Page 21: Configuration Menu

    CBUPRI/E1 SBUPRI-23/30 User Manual 3.2 Configuration menu The first two menus are unavailable - they are included to maintain the menu structure across the product range. Refer to the SBU Systems manual for details of how to set these menus on the Shelf Manager Module.
  • Page 22: Routing Menu

    3.2.2 Routing menu It is essential for the operation of the SBUPRI that Routing is correctly set for every operational port of the application cards. This menu below defines how incoming calls are ‘mapped’ to user ports by defining the MSN and/or sub-addresses for the record entries. To each record number is assigned an application card and its associated port, also an MSN (otherwise known as DDI) or sub-address.
  • Page 23 CBUPRI/E1 SBUPRI-23/30 User Manual ENTER C) SET SUB RECORD ADDRESS (1-48): ENTER SUBADDRESS ENTER D) DEST PORT RECORD: TYPE A) ACCEPT SINGLE CALL ONLY B) ACCEPT MULTIPLE CALLS ENTER E) CLEAR RECORD: RECORD ENTER F) LIST RECORD: RECORD 3–4 The record number to be assigned with a sub-address.
  • Page 24 G) LIST RECORDS 1-16 H) LIST RECORDS 17-32 I) LIST RECORDS 33-48 80-14005000-01 SBUPRI Command Menu Slot and port routing for records 1-16 is displayed. Slot and port routing for records 17-32 is displayed. Slot and port routing for records 33-48 is displayed.
  • Page 25: Isdn Menu

    CBUPRI/E1 SBUPRI-23/30 User Manual 3.2.3 ISDN Menu The ISDN sub-menu has a total of six entries A-F, of which A-C are only applicable in T1 mode with the SBUPRI-23. Several sub-menus are applicable only for either E1 or T1. The L1 Pulsemask menu is exclusive to T1 and provides eight selections for line length.
  • Page 26 C) L1 SYNC GAIN PERSISTENCE TIMER The Sync Gain Persistence Timer is the time period beginning when synchronisation is first detected that the Synchronised condition must persist for before the Synchronisation Gained Condition is recognised by the module. D) L3 ISDN DISPLAY A) ENABLED B) DISABLED (F) E) L3 INTER-CALL GAP...
  • Page 27 CBUPRI/E1 SBUPRI-23/30 User Manual F) L3 OUTGOING B-CHANNEL A) PREFERENCE B) CHANNEL SEARCH This menu is only available in E1 mode. This is the Default setting for the T1 menu. This is the Default setting for the E1 menu. 3–8...
  • Page 28: Regulatory Requirements

    B.A.B.T. Approval numbers: CBUPRI/E1: AA605507 SBUPRI-30: AA608583 The CBUPRI/E1 and SBUPRI-30 are approved for connection to ISDN services provided telecommunications operator. 1. Only connect apparatus complying with the requirements of TNV in accordance with clause 6.2 of EN 60 950 to the port on the rear panel of your unit marked ISDN ‘S’.
  • Page 29: Usa Compliance For Fcc And Industry Canada

    The following paragraphs describe requirements and information based on FCC rules, and are applicable to the SBUPRI-23 only. CBUPRI/E1 is not approved for use in USA or Canada. 4.2.1 FCC Rules, Part 15 The SBUPRI-23 card has been tested and comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 30: Service

    4.2.2.2 Service In the event of equipment malfunction, all repairs should be performed by Cabletron Systems or an authorised agent. It is the responsibility of users requiring service to report the need for service to Cabletron Systems or to one of our authorised agents. Service can be facilitated through our office at: Cabletron Systems Inc., 35 Industrial Way, Rochester, NH 03866 USA.
  • Page 31: Telephone Company Facility Changes

    CBUPRI/E1 SBUPRI-23/30 User Manual 4.2.2.5 Telephone Company Facility Changes The telephone company can make changes in its facilities, equipment, operations, or procedures that can affect the operation of your equipment. If they do, you should be notified in advance so you have an opportunity to maintain uninterrupted telephone service.
  • Page 32: Glossary Of Terms

    Here are some descriptions of most used abbreviations in this manual: Alarm Indication Signal Basic Rate Interface CBUPRI/E1 Primary Rate Interface Module (E1 only) Cyclic Redundancy Check (an indication of errors received by monitoring the CRC bits in timeslot 0...
  • Page 33 CBUPRI/E1 SBUPRI-23/30 User Manual SBUQHB Quad High Speed Backup Module SBUQLS Quad Low Speed Access Module SBUQLB Quad Low Speed Backup Module SBU-NM Personal Computer Network Controller. (Fivemere proprietary network management system). Screened Twisted Pair (cable) Remote Alarm Indication Terminal Adaptor 5–2...

This manual is also suitable for:

Sbupri-23Sbupri-30

Table of Contents