Normal Mode Error-Free Sequence - Cabletron Systems CSMIM-T1 Installation Manual

Enterasys csmim-t1 communication server: install guide
Hide thumbs Also See for CSMIM-T1:
Table of Contents

Advertisement

5.2.1.1

Normal Mode Error-Free Sequence

Table 5-2
summarizes the LED display states during error-free power-up
in normal mode. The following subsections describe these states.
Table 5-2 Normal Mode Error-Free LED States
Activity
N1: LEDs OK
N2: Hardware OK
Key:
On continuously.
Off.
Flashing irregularly.
Flashing regularly (about 1Hz).
Activity N1: Testing LEDs
All front panel LEDs light for a few seconds, then all but the Ethernet
LED (segment indicator) turn off, confirming that all LEDs are
operational.
Activity N2: Testing the Hardware
During the power-up sequence, the CSMIM-T1 runs a series of self-test
diagnostics. These diagnostics test internal hardware functions. If a test
fails, the ATTN and STAT LEDs flash and an error message is displayed
on the console port. The TRAF indicator flashes during the power-up
self-tests. After the self-tests complete, only the STAT and Ethernet
channel indicator remain on.
CSMIM-T1 Hardware Installation Guide
Power-Up and Boot Procedures
STAT
ATTN
Green
Amber
TRAF
Green
5-5