5.3 X5 cooling unit

X5 Cooler
X5 Cooler
Feature
Supply voltage
Maximum supply current
Cooling power
Recommended coolant
Maximum coolant pressure
Tank volume
Operating temperature
range
Storage temperature range
EMC class
Degree of protection
Package external dimensions
Weight
Standards
© Kemppi
@ 380...460 V
@ 1 l/min
With recommended coolant
When mounted
L x W x H
120
U
1
I
1max
X5 FastMig
Operating manual - EN
Value
380...460 V +/- 10 %
0.5 ... 0.7 A
1.1 kW
MGP 4456 (Kemppi mixture)
0.4 MPa
4 l
-10...+40 °C
-40...+60 °C
A
IP23S
790 x 300 x 320 mm
14.3 kg
IEC 60974-2, -10
1920960 / 2144