Kemppi X5 FastMig Operating Manual page 77

Hide thumbs Also See for X5 FastMig:
Table of Contents

Advertisement

WF end step
Dynamics
Post current
Wire feed speed min
Wire feed speed max
Voltage min
Voltage max
Remote mode
Water cooler
Wire retract
- Retract delay
- Retract length
Weld data averages
Voltage display mode
Safe wire inch
Cable calibration
© Kemppi
ON/OFF
Default = OFF
Min/Max = -10.0 ... +10.0, step 0.2
Default = 0
-30 ... +30, step 1
Default = 0
Min/Max = 0.5 ... 25 m/min, step 0.1
Default = 0.5 m/min
Min/Max = 0.5 ... 25 m/min, step 0.1
Default = 25 m/min
Min/Max = According to welding equip-
ment specifications, step 0.1
Min/Max = According to welding equip-
ment specifications, step 0.1
OFF/Remote/Gun
Default = OFF
OFF/Auto/ON
Default = OFF
OFF/ON
2...10 s, step 1
Default = 5 s
1...10 cm, step 1
Default = 2 cm
Without slopes / Entire weld
Default = Without slopes
Terminal voltage / Arc voltage
Default = Arc voltage
ON/OFF
Default = OFF
Calibrate/Cancel
77
Operating manual - EN
Wire feed end step. This feature prevents
the filler wire from sticking to the work
piece when the welding ends. This is
accomplished by pulling the wire back
briefly.
Controls the short circuit behavior of the
arc. The lower the value the softer the arc,
the higher the value the rougher the arc.
Post current setting affects the wire
length at the weld end. This also enables
the optimum wire length for the start of
the next weld.
Minimum and maximum limits for the
wire feed speed adjustment.
Minimum and maximum limits for the
welding voltage adjustment.
If remote controller is not connected, this
selection is not available.
This is an automatic wire retract feature.
Once the arc is extinguished, the wire is
retracted for additional safety. The user
can change the wire retract delay and
length settings.
This feature allows the user to change
how the weld data averages are
calculated: with or without the slope
phases in the beginning and in the end
of the weld.
This setting affects the calculation of the
averages for the following: welding
voltage (terminal and arc voltage), weld-
ing current, welding power and wire feed
speed.
This defines which is shown on the con-
trol panel display, terminal or arc voltage
When ON, and the arc doesn't ignite, the
filler wire is fed 5 cm. When OFF, 5 m of
filler wire is fed.
The date and time and the calibration
information of the previous calibration is
also shown.
Refer to "Calibrating welding cable" on
page 73 for cable calibration.
X5 FastMig
1920960 / 2144

Advertisement

Table of Contents
loading

Table of Contents