Kemppi X5 FastMig Operating Manual page 76

Hide thumbs Also See for X5 FastMig:
Table of Contents

Advertisement

1.
Press the Settings menu button.
2.
Switch between the menu items by turning the control knob.
3.
Select a menu item for adjustment by pressing the control knob button.
4.
Adjust the parameter value (or other settings value) by turning the control knob.
5.
Exit the adjustment dialog by pressing the control knob button again.
Rarely used settings items are hidden by default. Those are available in the advanced settings menu. To enter the
advanced Settings menu, press the Settings button for approx. 5 seconds.
Welding parameters, settings and feature descriptions
MIG settings
The parameters listed here are available for adjustment with the MIG process.
Parameter
Pre gas
Post gas
Creep start level
Touch Sense Ignition
Crater fill
- Crater fill time
- Crater fill wire feed speed
- Crater fill voltage
© Kemppi
Parameter value
Min/Max = 0 ... 9.9 s, step 0.1 s
0 = OFF
Default = auto
Min/Max = 0 ... 9.9 s, step 0.1 s
0 = OFF
Default = auto
Min/Max = 10 ... 90 %, step 1 %
Default = auto
ON/OFF
Default = OFF
ON/OFF
Default = OFF
Min/Max = 0.1 ... 5 s, step 0.1 s
Default = 1.0 s
Min/Max = 0.5 ... 25 m/min
Step: 0.05 (if wire feed speed < 5 m/min),
0.1 (if wire feed speed >= 5 m/min)
Default: 5 m/min
Min/Max = 8 ... 60 V, step 0.1 V
Default = 18 V
76
Operating manual - EN
Description
Welding function that starts the shielding
gas flow before the arc ignites. This
ensures that the metal does not come
into contact with air at the start of the
weld. Time value is preset by the user.
Used for all metals, but especially for
stainless steel, aluminum and titanium.
Welding function that continues the
shielding gas flow after the arc has extin-
guished. This ensures that the hot weld
does not come into contact with air after
the arc is extinguished, protecting the
weld and also the electrode. Used for all
metals. Especially stainless steel and
titanium require longer post gas times.
The Creep start function defines the wire
feed speed before the welding arc
ignites, that is, before the filler wire
comes in contact with the workpiece.
When the arc ignites, the wire feed speed
is automatically switched to the normal
user-set speed. The Creep start function
is always on.
Touch Sense Ignition delivers minimum
spatter and stabilizes the arc immediately
after ignition.
When welding with high power, a crater
is usually formed at the end of the weld.
The Crater fill function decreases the
welding power / wire feed speed at the
end of the welding job so that the crater
can be filled using a lower power level.
The Crater fill level, voltage and time
(only in 2T trigger mode) are preset by
the user.
X5 FastMig
1920960 / 2144

Advertisement

Table of Contents
loading

Table of Contents