Post gas
Current
MMA welding parameters
The parameters listed here are available for adjustment with the MMA process.
Parameter
Dynamics
Hot start level (MMA)
Current
Gouging parameters
The parameters listed here are available for adjustment with the gouging process.
Parameter
Current

3.3.5 Auto control panel: Info view

The Info view shows information on the device usage. Through this view it is also possible to access the error logs, list of
installed welding programs, additional operating information and device info, such as the software version and equip-
ment serial numbers.
© Kemppi
0.0 ... 9.9 s, step 0.1
0.0 = OFF
10 ... machine size A, step 1
Default = 50 A
Parameter value
-10.0 ... +10.0, step 0.2
Default = 0
-30 ... +30
Default = 0
10 ... machine size A, step 1
Default = 50 A
Parameter value
10 ... machine size A, step 1
Default = 50 A
88
Operating manual - EN
Welding function that continues the
shielding gas flow after the arc has extin-
guished. This ensures that the hot weld
does not come into contact with air after
the arc is extinguished, protecting the
weld and also the electrode. Used for all
metals. Especially stainless steel and
titanium require longer post gas times.
Welding current adjustment.
Description
Controls the short circuit behavior of the
arc. The lower the value the softer the arc,
the higher the value the rougher the arc.
Welding function that uses higher or
lower wire feed speed and welding cur-
rent at the start of the weld. After the Hot
start period the current changes to nor-
mal welding current level. This facilitates
the start of the weld especially with alu-
minum materials. In MMA the Hot start
level is preset by the user.
Welding current adjustment.
Description
Current adjustment.