1-MIG welding parameters
The parameters listed here are available for adjustment only with the 1-MIG process.
Parameter
Upslope
Upslope start level
Upslope time
Hot start
Hot start level
Hot start time
Crater fill
- Crater fill start level
- Crater fill time
- Crater fill end level
Current
Fine tuning
Wise feature
Wire feed speed limit min
Wire feed speed limit max
TIG welding parameters
The parameters listed here are available for adjustment with the TIG process.
Parameter
Trigger logic
© Kemppi
Parameter value
ON/OFF
ON: 10 ... 100 %, step 1
Default = 50
ON: 0.1 ... 5 s, step 0.1
Default = 0.10
ON/OFF
ON: -50 ... +200 %, step 1
Default = 40
ON: 0.0 ... 9.9 s, step 0.1
Default = 1.2 s
ON/OFF
10 ... 150 %, step 1
Default = 100
0.0 ... 10.0 s, step 0.1
Default = 1.0 s
10 ... 150 %, step 1
Default = 30
10 ... machine size A, step 1
Default = 50 A
Example: -10.0 ... +10.0 V *
Step 0.1 V
None, WiseFusion, WisePenetration+,
WiseSteel
Min/Max = 0.5 ... 25 m/min, step 0.1
Default = 0.5 m/min
Min/Max = 0.5 ... 25 m/min, step 0.1
Default = 25 m/min
Parameter value
2T, 4T
87
Operating manual - EN
Description
Upslope is a welding function that
determines the time, during which the
welding current gradually increases to
the desired welding current level at the
start of the weld. The upslope start level
and time are preset by the user.
Welding function that uses higher or
lower wire feed speed and welding cur-
rent at the start of the weld. After the Hot
start period the current changes to nor-
mal welding current level. This facilitates
the start of the weld especially with alu-
minum materials. The Hot start level and
time (only in 2T trigger mode) are preset
by the user.
When welding with high power, a crater
is usually formed at the end of the weld.
The Crater fill function decreases the
welding power / wire feed speed at the
end of the welding job so that the crater
can be filled using a lower power level.
With 1-MIG process, Crater fill start level,
duration and end level are preset by the
user.
Welding current adjustment. With
WisePenetration+ only.
Fine tuning of the welding voltage.
* The voltage range for fine tuning is
defined by the active welding program.
When selected, a list of available Wise fea-
tures is opened for selection.
Minimum and maximum limits for the
wire feed speed adjustment.
Description
Welding guns can have several altern-
ative trigger operation modes (trigger
logics). Most common are 2T and 4T. In
2T mode you hold the trigger down
while welding. In 4T mode you press and
release the trigger to start or to stop weld-
ing.