Remote mode
(with 2-knob remote control)
Water cooler
Voltage display mode
Wire retract
- Retract delay
- Retract length
Subfeeder type
(in MIG mode and with X5 Wire Feeder
300 Auto+ only)
Weld data duration
Weld data averages
Date
Time
Language
© Kemppi
Welding / Channel
OFF/Auto/ON
Default = OFF
Terminal voltage / Arc voltage
Default = Arc voltage
OFF/ON
2...10 s, step 1
Default = 5 s
1...10 cm, step 1
Default = 2 cm
Subfeeder model / OFF
Default = OFF
0...30 s, step 1
0 = OFF
Default = 5 s
Without slopes / Entire weld
Default = Without slopes
Current date
Current time
Available languages
91
Operating manual - EN
This determines what is changed with
the remote, welding parameter(s) or
memory channel (available
channels: 1...5). In automatic 1-MIG mode,
the remote control parameters are
defined by the welding program.
If remote controller is not connected and
remote not selected, this selection is not
available.
Note: When the remote mode is set to
'Channel', only the left remote control
knob is in use.
When ON is selected, the coolant is cir-
culated continually, and when Auto is
selected, the coolant is circulated only
during welding. The Auto mode is avail-
able only with welding guns supporting
the automatic detection.
This defines which is shown on the con-
trol panel display, terminal or arc voltage
This is an automatic wire retract feature.
Once the arc is extinguished, the wire is
retracted for additional safety. The user
can change the wire retract delay and
length settings.
Note: Wire retract function is disabled if a
subfeeder is connected.
If a compatible subfeeder is connected,
select the subfeeder from the list.
Compatible subfeeders:
SuperSnake GTX (10m, 15m, 20m, 25m),
SuperSnake GT02S/GT02SW (10m, 15m,
20m, 25m), Binzel PP401D, Binzel PP36D.
Note: With SuperSnake GT02S/GT02SW
models, only motor synchronization is
supported.
This defines if and how long the weld
data summary is shown after each weld.
This feature allows the user to change
how the weld data averages are
calculated: with or without the slope
phases in the beginning and in the end
of the weld.
This setting affects the calculation of the
averages for the following: welding
voltage (terminal and arc voltage), weld-
ing current, welding power and wire feed
speed.
X5 FastMig