VRD error
42
High current in
wire feeder
motor
43
Overcurrent in
wire feeder
motor
44
Wire speed
measurement is
missing
50
Welding pro-
gram error
62
Power source
not found
81
Welding pro-
gram data miss-
ing
244
Internal memory
failure
250
Internal memory
failure
© Kemppi
Open circuit voltage exceeds the VRD limit.
There may be too much pressure in the
wire feed rolls or dirt in the wire line.
There may be too much pressure in the
wire feed rolls or dirt in the wire line.
Faulty sensor or wiring in wire feeder.
Required welding program is not installed.
No power source is connected to the wire
feeder, or connection is faulty.
Welding program data has been lost.
Initialization failed (%sub:%device).
Memory communication failed (%sub-
:%device).
Restart the power source. If problem persists, contact
Kemppi service.
Adjust the feed roll pressure. Clean the wire line.
Change worn parts in the welding gun.
Adjust the feed roll pressure. Clean the wire line.
Change worn parts in the welding gun.
Restart the welding system. If problem persists, con-
tact Kemppi service.
Contact Kemppi service for installing welding pro-
grams.
Check the control cable and its connectors.
Restart the power source. If problem persists, contact
Kemppi service.
Restart welding system. If problem persists, contact
Kemppi service.
Restart welding system. If problem persists, contact
Kemppi service.