ELNEC s. r. o.
After an operation with a device is executed, one of the OK or ERROR (status) LEDs on the
programmer will lights in dependence on the result of an operation and the BUSY LED will
blinking.
If the program detects removal of a device, then status LED will switched off, but the BUSY
LED will still blinking to indicate readiness of the program to repeat last operation with new
device.
After the program indicates one or more pins of (new) device in the ZIF socket of the
programmer, the BUSY LED will goes to light continually. From this the program will wait a
requested time for insert the rest pins of new device. If a requested time (Device insertion
complete time) overflows and a device is not correctly inserted, the program will lights the
ERROR LED to indicate this state. After new device was inserted correctly, the program will
switch off all status LEDs, except BUSY, and will start an operation with new device.
This mode may be enabled or disabled by item Automatic YES! mode. If a new programmer
is selected Options / Find programmer, this mode will be disabled.
The Response time is interval between insertion of the chip into the ZIF socket and the start
of selected device operation. If longer positioning of the chip in the ZIF socket is necessary
select elongated response time.
Programming adapter used shows name of adapter used with currently selected device.
Pins of programmer's ZIF excluded from sensing contains list of pins that will be ignored
from testing by Automatic YES!. The reason to ignore the pins is mostly - capacitors
connected to these pins.
Button Setting Automatic YES! parameters will run wizard that can detect permanently
connected pins (pins with capacitors) and set these pins to list of pins excluded from sensing.
After selecting of device, list of excluded pins contains default excluded pins for selected
device adapter. If other bypass capacitors to universal programmer and/or device adapter are
added by customer, there is necessary to run Automatic YES! parameters wizard to
override default parameters and detect other pins with capacitors.
In Device removal hold off time is time period between you removed device from the ZIF
socket and the time when software starts to check the socket for new device inserted. This
interval is in seconds and must be from 1 to 120 (default value is 2 seconds).
In Device insertion complete time is possible to set a time within all pins of the device have
to be properly inserted after a first pin(s) detected so that the program will not detects
incorrectly inserted device. This interval is in seconds and must be from 1 to 120 (default
value is 5 seconds).
The Suspend on error defines if the Automatic YES! function will be temporary disabled on
error to see result of operation or will going on without suspension.
The options are set to defaults after new device is selected by Device / Select device
This setting is saved to disk by command Options / Save options.