Chapter 9
General Checklist
Should you experience problems using the DT3034 board, follow these steps:
1. Read all the documentation provided for your product. Make sure that you have added
2. Check the OMNI CD for any README files and ensure that you have used the latest
3. Check that your system meets the requirements stated in
4. Check that you have installed your hardware properly using the instructions in
5. Check that you have installed and configured the device driver properly using the
6. Search the DT Knowledgebase in the Support section of the Data Translation web site (at
If you still experience problems, try using the information in
problem. If you cannot identify the problem, refer to
Symptom
Board does not
respond.
Intermittent
operation.
Data appears to be
invalid.
136
any "Read This First" information to your manual and that you have used this
information.
installation and configuration information available.
the README file on the OMNI CD.
2.
instructions in
Chapter
2.
www.mccdaq.com) for an answer to your problem.
Table 22: Troubleshooting Problems
Possible Cause
The board configuration is
incorrect.
The board is incorrectly aligned
in a PCI expansion slot.
The board is damaged.
Loose connections or
vibrations exist.
The board is overheating.
Electrical noise exists.
An open connection exists.
A transducer is not connected
to the channel being read.
The board is set up for
differential inputs while the
transducers are wired as
single-ended inputs or vice
versa.
Table 22
page
138.
Possible Solution
Check the configuration of your device driver to
ensure that the board name and type are correct.
Check that the slot in which your DT3034 board is
located is a PCI slot and that the board is correctly
seated in the slot.
Contact Data Translation for technical support; refer
to
page
138.
Check your wiring and tighten any loose connections
or cushion vibration sources.
Check environmental and ambient temperature;
consult the board's specifications on
manual and the documentation provided by your
computer manufacturer for more information.
Check your wiring and either provide better shielding
or reroute unshielded wiring.
Check your wiring and fix any open connections.
Check the transducer connections.
Check your wiring and ensure that what you specify
in software matches your hardware configuration.
Chapter