Chapter 8 I/O Output; Select Output Signal; Set Output Signal; Enable Line Inverter - HikRobot CoaXPress User Manual

Area scan camera
Hide thumbs Also See for CoaXPress:
Table of Contents

Advertisement

CoaXPress Area Scan Camera
User Manual
·

Chapter 8 I/O Output

8.1 Select Output Signal

The camera has 1 opto-isolated output (Line 1), and 1 bi-directional I/O (Line 2) that can be
configured as output signal.
Here we take Line 2 as an example to introduce how to select output signal. You select Line 1 or
Line 2 as line selector according to actual demands.
Click Digital IO Control, select Line 2 as Line Selector, and select Strobe as Line Mode to set line 2
as output signal.
Figure 8-1 Set Line 2 as Output Signal

8.2 Set Output Signal

The output signal of the camera is switch signal that can be used to control external devices such
as light source, PLC, etc.

8.2.1 Enable Line Inverter

The line inverter function allows the camera to invert the electrical signal level of an I/O line, and
meets requirements of different devices for high or low electrical signal level.
Click Digital IO Control > Line Selector, select line for Line Selector, and check Line Inverter to
enable.
Figure 8-2 Enable Line Inverter
The Line Inverter parameter is disabled by default.