26. IN-SYSTEM PROGRAMMING (ISP)
26.1 Getting Started / Installation
The following section details the procedure for accomplishing the
installation procedure.
1. Connect the serial(RS-232C) cable between a target
board and the COM1 serial port of your PC.
2. Configure the COM1 serial port of your PC as follow-
ing.
Baudrate
115,200
Data bit
8
Parity
No
Stop bit
1
Flow control
No
26.2 Basic ISP S/W Information
November 4, 2011 Ver 2.12
3. Turn your target B/D power switch ON. Your target B/
D must be configured to enter the ISP mode.
4. Run the MagnaChip ISP software.
5. Press the Reset Button in the ISP S/W. If the status win-
dows shows a message as "Connected", all the condi-
tions for ISP are provided.
MC80F0304/08/16