October 2002
Basic hardware check
Introduction
This section describes some basic checks that you can do when you start up
the server.
To run the confidence test
1 Power on the server and observe the front panel display.
Result: All LEDs on the panel illuminate for a few seconds. The green
power LED remains illuminated.
2 Observe the following server actions:
Cooling fans on the front panel start up, and the red fault LED next to
each fan extinguishes.
Drives spin up, and the amber hard drive activity LEDs over the front
panel display, extinguish, and then flash with activity.
LEDs illuminate temporarily as the system checks the floppy drive,
tape drive, and CD-ROM drive.
The LED on each power supply lights up red as supply fans spin up
and components charge. LEDs turn green when the attached power
supply is fully operational.
3 Check the monitor for any error messages as the server counts RAM and
completes a Power-On Self-Test (POST).
See "Power-On Self-Test diagnostics" on page 24 for more details on
POST.
Part 5: 1002rp Server Maintenance and Diagnostics
Troubleshooting your CallPilot system
23