October 2002
d. Power up the server.
Result: The system prompts a key to run configuration utility or
ALT+F10 to continue.
e. Press any key to enter the configuration utility.
f. Select Objects
three drives.
g. Exit the utility, and then reboot.
Result: The system boots up to the previous configuration used
before the software upgrade, and an audible alarm indicates the
CRITICAL state of all three drives.
Note: At this time, you can silence the alarm, but do not disable it.
h. Once the system is fully booted, insert the drives that have the failed
software upgrade into their original locations. The system starts to
rebuild them, overwriting the data as soon as their presence is
detected.
8 The software upgrade or the revert from a failed software upgrade is now
complete.
Note: The audible alarm, if left on, should stop automatically at this point.
Part 5: 1002rp Server Maintenance and Diagnostics
Maintaining an AMI MegaRAID Elite 1600 RAID system
➝
Physical Drive
➝
Make ONLINE for each of the
177