Replacing a hard drive, tape drive, CD-ROM drive, or floppy drive
To replace hot-pluggable SCA SCSI hard drives
1 Ensure the new hard drive has the SCSI ID set to 0, termination
disabled, and parity checking enabled.
2 Open the front bezel doors.
3 Locate the SCA SCSI drive frame below a cooling fan and beside the
media drive.
4 Loosen the two thumbscrews on the faulty hard drive's carrier, and
remove the carrier from the chassis.
5 Remove the faulty drive by loosening the four Phillips-head screws that
secure it to the carrier.