Nortel CallPilot 1002rp Installation And Configuration Manual page 170

Maintenance and diagnostics
Hide thumbs Also See for CallPilot 1002rp:
Table of Contents

Advertisement

Maintaining an AMI MegaRAID Elite 1600 RAID system
5 In the Configure menu, select New Configuration. Press Yes to proceed.
Result: The system should display both SCSI channels, each having
three drives. SCSI ID's should be listed in order from 0 to 2 for each
channel, starting from the top. All disk drives should be in the READY
state to proceed.
6 Use the space bar to create the first logical drive by selecting A01-01
(the first drive from channel 0), and A01-02 (the first drive from channel
1).
Result: After the selection is made, the drives blink.
7 Press Enter to create the first logical drive.
8 Repeat steps 5 to 7 of this procedure to create packs for the second and
third logical drives labeled respectively as
A02-01 and A02-02 as the second pack
A03-01 and A03-02 as the third pack
9 To configure the logical drives, press F10.
Result: The system prompts you for each of the three logical drives to
select consecutively RAID 1; Size.
10 Accept the size displayed. Accept SPAN, and change the last value to
NOSPAN.
11 Press Enter to accept these new values. Repeat for all three logical
drives.
Result: The system prompts you to save the configuration.
12 Press ESC to save and exit the submenu.
13 In the main menu, choose the Initialize submenu.
14 Press F2 to select all three logical drives.
15 Press F10, and then select YES, to initialize the drive packs.
16 When the initialization is complete, press any key to return to the main
menu.
17 Press ESC to exit the utility and save the configuration when prompted.
18 Press CTRL-ALT-DELETE to reboot the server.
170
Standard 1.0
CallPilot

Advertisement

Table of Contents
loading

Table of Contents