6. Lightware Device Controller (LDC)
6. Lightware Device Controller (LDC)
6.5.7. Scaler Panel - Output Side (RX/TRX Modes)
Clicking on the Scaler panel on the HDMI output 1 of the receiver/transceiver opens the Scaler properties.
This feature allows to rescale the incoming stream to other resolution and refresh rate and fit to the sink
device.
#scaler #csc #colorspace #colorrange
The most important signal and display information and settings are available on the panel.
Scaler panel for the HDMI out 1 (RX)
Available settings and tools:
Scaling mode
– Passthrough: the scaler is in pass-through mode.
– Forced resolution: the scaling is active, the selected value in the forced resolution option will be
applied on the video signal;
– EDID based: the scaler forces the resolution which is read out from the EDID of the connected sink
device.
Forced resolution: list of the available resolutions with refresh rate values. The selected one will be
applied on the video signal. See the available resolution in the
Image position (Stretch / Fit / Center)
Color space conversion (No conversion / RGB / YCbCr 4:4:4 / YCbCr 4:2:2);
Color range (No conversion / Full range / Limited range);
No Sync Screen (Test Pattern)
settings;
Signal freeze button: the signal freezes at the last video frame on the sink device (the sink may show a
broken frame either).
#freeze
Reloading factory default settings for the selected port.
series – Extender Application Mode – User's Manual
series – Extender Application Mode – User's Manual
Resolutions of the Scaler / FRC
section.
Applied F-series endpoint firmware package: v2.0.0 | Applied R-series endpoint firmware package: v2.0.0 | LDC software: v2.5.9b3
6.5.8. FRC - Output Side (RX Mode)
Clicking on the FRC (Frame Rate Converter) panel on the HDMI output 2 of the receiver opens the properties
of the Frame rate converter.
#frc #csc #colorspace #colorrange
FRC panel for the HDMI out 2 (RX)
Available settings and tools:
Output resolution mode
– Passthrough: the FRC is in pass-through mode.
– Forced resolution: the FRC is active, the selected value in the forced resolution option will be
applied on the video signal;
– EDID based: the FRC forces the resolution which is read out from the EDID of the connected sink
device.
Forced resolution: list of the available resolutions with refresh rate values. The selected one will be
applied on the display device. See the available resolution in the
section.
Color space conversion (No conversion / RGB / YCbCr 4:4:4 / YCbCr 4:2:2);
Color range (No conversion / Full range / Limited range);
No Sync Screen (Test Pattern)
settings;
Signal freeze button: the signal freezes at the last video frame on the sink device (the sink may show a
broken frame either).
#freeze
Reloading factory default settings for the selected port.