Step 3. Establish connection between the additional Neutrik opticalCON DUO connector and the R100
endpoint device by a singlemode/multimode Neutrik opticalCON DUO BiDi cable. The following figure
shows the correct cabling layout of optical connectors on the R100 endpoint device:
Layout of the 2xSM-BiDi-DUO model (rear view)
SFP+ modules behind th Neutrik opticalCON DUO connector
Channel
Type of the SFP+ module
A
Finisar FTLX2072D327
B
Finisar FTLX2072D333

ATTENTION!
The 2xSM-BiDi-DUO model does not support the Neutrik opticalCON DUO crossed fiber
wiring (A-A; B-B) cables. Please use standard (A-B) cables only.
ATTENTION!

Always be sure that the fiber optical mode of the entire fiber optical equipment (SFP+
modules, LC patch cables, Neutrik connectors, and cables) and R100 endpoint device are the same.
Connecting to the 2xSM-BiDi-DUO model requires singlemode equipment.
Required fiber optical equipment for connecting an F110 and an R100 2xSM-BiDi-DUO endpoint device

INFO:
This method does not work in case of using DAC cables in the F-series endpoint device.
series – Extender Application Mode – User's Manual
series – Extender Application Mode – User's Manual
Layout of the extra connector
(rear view)
Wavelength
1271 nm
1331 nm
Applied F-series endpoint firmware package: v2.0.0 | Applied R-series endpoint firmware package: v2.0.0 | LDC software: v2.5.9b3
4.8. Startup of the System
The following section describes the startup of the UBEX extender system step-by-step from the beginning to
the displayed video on the sink devices.
ATTENTION!

Before powering on the system please check the
installation steps are met with the connection requirements.
4.8.1. Switch on the Devices
Power on the UBEX endpoints, the source, and the sink devices connected to the extenders.

INFO:
After the booting procedure of the UBEX extenders, the last configuration is loaded automatically.
4.8.2. Configure the Operation Mode
All endpoint devices are manufactured as transmitter (TX) by default. Set up the operation mode for the
endpoints using as receivers or transceivers with the Front panel LCD menu. See the details in the
Mode
section.
4.8.3. Establish the Connection with the UBEX Extenders
Establish the connection between one of the UBEX extenders and the controller device via LAN network. It
is highly recommended to connect one of the extenders due to the following reasons:
The two UBEX endpoints are visible for each others in the case of correct SFP+ link connection.
User Ethernet is also transmitted over the SFP+ interface so be sure not to create network loop!
Network Settings
Check the network settings of the UBEX extenders. You can find the factory default settings of the endpoint
in the
Factory Default Settings
section. The network settings can be changed using two different methods:
via LCD menu - see the details in the
via LDC software, in the Device discovery window - see the details in the
section.
Lightware Device Controller Software
All required settings can be done by control software, the Lightware Device Controller (LDC). See all the
details about it in the
Lightware Device Controller (LDC)
Discovering the Device
Step 1. Open the LDC software. The Device discovery
window
will
launch
automatically
discover all available Lightware devices on
the network where the controller device is
connected to.
Step 2. Select the endpoint device which you want
to connect to and click on the green Connect
button.
Connections
section to be sure all
Network
section.
Establishing the Connection
chapter.