Operation
Operating Instructions 868-M - 01.0 - 12/2020
4.4.1
In 1-needle machines
Fig. 6: In 1-needle machines
①
②
③
(1) - Needle bar
(2) - Screw
To change the needle in a 1-needle machine:
1.
Turn the handwheel until the needle bar (1) has reached the
upper end position.
2.
Loosen the screw (2).
3.
Pull the needle out towards the bottom.
4.
Insert the new needle into the hole in the needle bar (1) until
it reaches the end stop.
Important
Align the new needle in such a way that the groove (3) faces the
hook.
5.
Tighten the screw (2).
Order
Always adjust the clearance between the hook and the needle after
changing to a different needle thickness ( Service Instructions).
(3) - Groove
②