Information Messages - Dürkopp Adler 868-M Operating Instructions Manual

Table of Contents

Advertisement

138

10.2.1 Information messages

Information
1203
Position not reached
(during thread cutting,
reversal, etc.)
2020
DACextension box not
responding
2021
Sewing motor encoder
plug (Sub-D, 9-pin)
not connected to
DACextension box
2120
DA stepper card 1 not
responding
2121
DA stepper card 1 encoder
plug (Sub-D, 9-pin) not
connected
2122
DA stepper card 1 flywheel
position not found
2220
DA stepper card 2 not
responding
Possible cause
Operating Instructions 868-M - 01.0 - 12/2020
Troubleshooting
Remedial action
• Check the controller
settings and change
them if required; make
mechanical changes to
the machine (e.g. thread
cutter, setting for belt
tension, etc.)
• Check position (thread
lever at top dead center)
• Check connection cables
• Check LEDs of
DACextension box
• Software update
• Connect encoder cable to
DACextension box using
the correct connection
• Check connection cables
• Check LEDs of
DACextension box
• Software update
• Connect encoder cable to
the control, use correct
connection
• Check connection cables
• Check stepper motor 1 for
stiff movement
• Check connection cables
• Check LEDs of
DACextension box
• Software update

Advertisement

Table of Contents
loading

Table of Contents