Operation
Operating Instructions 868-M - 01.0 - 12/2020
Important
Align the new needles in such a way that the grooves (3) face the
hook. As viewed from the user side, the groove (3) of the left needle
must point to the left, while the groove (3) of the right needle must
point to the right.
6.
Tighten the screw (2).
Order
Always adjust the clearance between the hook and the needle after
changing to a different needle thickness ( Service Instructions).
Disturbance
An incorrect hook distance can cause the following disturbances:
• Changing to a thinner needle:
• Missing stitches
• Thread damage
• Changing to a thicker needle:
• Damage to the hook tip
• Damage to the needle