Wall Mounted Cabinets
Pattern Numbers Represented:
Wall Mounted Wood Cabinets,
YSWM____
Wall Mounted Metal Cabinets,
YSMWM___
Parts List:
Fasteners Appropriate for Wall, Not Supplied by
Knoll
Wall Rail Cleat for Wood Cabinet (A) or
Wall Rail Cleat for Metal Cabinet (B)
Wall Mount Wood or Metal Overhead Cabinet
Tools Needed:
Drill with Bit Appropriate for Fasteners
Level
Tape Measure
Please refer to the previous chart
for further recommendations.
STEPS
To Attach the Wall Rail Cleat:
1. To position the overhead at the appropriate
height, the wall rail cleat top edge needs
to be 63
/
" from the highest point off
7
32
the floor. Based on the horizontal position
required, the wall rail cleat should be inset
approximately 4" from the outside end of the
unit. Mark the wall to locate the wall rail cleat
location based on these requirements.
If the overhead is to align with
NOTE:
adjacent products, such as a floorstanding
cabinet, the recommended vertical
dimensions may need to be modified by any
floor leveling (high vs. low) conditions.
2. Begin attaching the wall rail cleat with
fastener starting at either end and a second
fastener at the other end while ensuring the
rail stays level horizontally. Once both ends
are leveled and secured, insert the remaining
fasteners to complete attachment.
To Mount Overhead Cabinet to Wall Cleat:
1. Gently lower the overhead unit into
place by aligning the factory installed rail
with the wall rail cleat just installed.
(A) Rail for 60" Cabinet- KR6TP40246
Rail for 72" Cabinet- KR6TP40247
Wall Rail
Vertical Location
Wall Rail Horizontal Location
(B) 35"- KR2MA1064H01
41"- KR2MA1064H02
47"- KR2MA1064H03
59"- KR2MA1064H04
71"- KR2MA1064H05