Wall Hung
Overview
Overview
Components
Wall Mounted Cabinets
Wall Mounting of Knoll Products
NEW
CONSTRUCTION
Stud
Wood studs, grade
Specification
#2 or better, 3 1/2"
minimum width, OR
Metal studs, minimum
25 gage thickness, 3
5/8" minimum width
Stud
Metal and wood studs
Centers
must be spaced at
16" c/c maximum
Stud
Metal and wood studs
Height
must extend upwards,
and be securely
attached to the roof/
floor structure above
Mounting
Insert a 2" X 6" wood
the Knoll
block, #2 grade or
Supplied
better, [or a Danback
Cleat,
flexible wood backing
Bracket,
system] horizontally
Frame, etc*
between each of the
studs to accommodate
the full width of the
cabinet, and beyond
to the next stud.
Fasten the wood block
to each stud using
three screws at the
ends of each block.
(Fasten the Danback™
as directed by the
manufacturer)
Fasten the Knoll
supplied wall mounting
cleat, bracket, frame,
etc directly to each
wood block every 6"
For wall mounting
structures that have a
rectangular frame-like
configuration: fasten
the top horizontal
element of the frame
to the wood blocking
every 6", and fasten
the lower horizontal
element to each
wall stud, using one
fastener per stud.
Fasten
#10 x 2 1/2" Grabber
the Knoll
Woodys Screws
supplied wall
or equiv. @ 6" c/c,
cleat with...
screwed directly into
the wood blocking
Additional
No
Required
Bracing
END
Danback™ flexible
woodbacking system
CONDITION
or equivalent
(only if cleat
extends
more than 6"
past stud)
Additional
Danback™ flexible
wood backing system
Required
or equivalent
Construction
Credenzas &
Desktop Towers &
Extender Tops
Bridge Overheads
Cinder Block or
Wood Stud Wall, the
Poured Concrete
studs being
Masonry Wall
FULL HEIGHT to the
roof/floor above
The wall must be a
Wood studs must be
minimum of 6" thick,
Grade #2, or better,
and must be full
3 1/2" minimum width
height to the roof/
floor structure above
N/A
Wood studs must
be spaced at 16" c/c
maximum
Fasten the Knoll
In the desired location
supplied cabinet
of the cabinet mounting
wall mounting cleat,
rail, remove an 8" high
TM
bracket, frame,
section of drywall the
etc. directly to the
width of the cabinet,
masonry wall every 6"
and beyond to the next
stud.
For wall mounting
structures that have a
Insert a 2" X 6" wood
rectangular frame-like
block, #2 grade or
configuration: fasten
better, horizontally
the top horizontal
between each of the
element of the frame
exposed studs.
to the wall every 6",
Fasten the wood block
and fasten the lower
to each stud using three
horizontal element to
screws at the ends of
the wall every 16"
each block.
Replace the drywall and
repair as desired.
Fasten the Knoll supplied
wall mounting cleat, rail,
frame, etc directly to the
wood block every 6"
For wall mounting
structures that have a
rectangular frame-like
configuration: fasten the
top horizontal element
of the frame to the
wood blocking every
6", and fasten the lower
horizontal element to
each wall stud, using
one fastener per stud.
3/16" x 3 1/2" Tapcon
#10 x 2 1/2" Grabber
Masonry Screws or
Woodys Screws
equiv. @ 6" c/c with
or equiv. @ 6" c/c,
screwed directly into the
1-1/4" embedment,
wood blocking
screwed directly into
the masonry wall
No
No
N/A
Toggler Snapskru
drywall anchors
with #8 x 2" screw
@ 4-1/2" c/c with
2-1/2" end distance
No
No
Hinged Modesty
& Support
Corners
Desks
EXISTING CONSTRUCTION
Wood Stud Wall,
Steel Stud Wall,
the studs being only
the studs being
Ceiling Height
FULL HEIGHT to the
roof/floor above
Metal studs must be
Wood studs must be
Grade #2, or better,
minimum 25 gage
3 1/2" minimum width
thickness, 3 5/8"
minimum width
Wood studs must be
Metal studs must be
spaced at 16"" c/c
spaced at 16" c/c
maximum"
maximum
Wood studs must be
braced above the ceiling,
and be securely attached
to the roof/floor structure
above
Affix #2 grade 'cap'
across the top of the
studs, then place diagonal
studs from the top cap up
to underside of the roof/
floor structure above
In the desired location
In the desired location of
of the cabinet mounting
the cabinet mounting rail,
remove an 8" high section
rail, remove an 8" high
section of drywall the
of drywall the width of the
width of the cabinet,
cabinet, and beyond to
the next stud.
and beyond to the next
stud.
Insert a 2" X 6" wood
Insert a 2" X 6" wood
block, #2 grade or better,
block, #2 grade or better,
[or a Danback™ flexible
horizontally between
wood backing system]
each of the exposed
horizontally between each
studs.
of the exposed studs.
Fasten the wood block
Fasten the wood block
to each stud using three
to each stud using three
screws at the ends of
screws at the ends of
each block.
each block.
Replace the drywall and
Replace the drywall and
repair as desired.
repair as desired.
Fasten the Knoll supplied
Fasten the Knoll supplied
wall mounting cleat, rail,
wall mounting cleat, rail,
frame, etc directly to the
frame, etc directly to the
wood block every 6"
wood block every 6"
For wall mounting
For wall mounting
structures that have a
structures that have a
rectangular frame-like
rectangular frame-like
configuration: fasten the
configuration: fasten the
top horizontal element
top horizontal element of
of the frame to the
the frame to the wood
wood blocking every
blocking every 6", and
fasten the lower horizontal
6", and fasten the lower
horizontal element to
element to each wall
each wall stud, using one
stud, using one fastener
fastener per stud.
per stud.
#10 x 2 1/2" Grabber
#10 x 2 1/2" Grabber
Woodys Screws or
Woodys Screws or
equiv. @ 6" c/c, screwed
equiv. @ 6" c/c, screwed
directly into the wood
directly into the wood
blocking
blocking
2 x 4's across the
No
top of the studs, with
diagonals attached
to underside of roof /
floor structure above
Toggler Snapskru
Toggler Snapskru
drywall anchors
drywall anchors
with #8 x 2"screw
with #8 x 2" screw
@ 4-1/2" c/c with
@ 4-1/2" c/c with
2-1/2" end distance
2-1/2" end distance
No
No
Bridges &
Returns
Peninsulas
The Graham Collection
Steel Stud Wall,
the studs being only
Ceiling Height
Metal studs must be
minimum 25 gage
thickness, 3 5/8"
minimum width
Metal studs must be
spaced at 16" c/c
maximum
Metal studs must be
braced above the ceiling,
and be securely attached
to the roof/floor structure
above
Affix metal bracing 'cap'
across the top of the
studs, then place diagonal
studs from the top cap up
to underside of the roof /
floor structure above
In the desired location of
the cabinet mounting rail,
remove an 8" high section
of drywall the width of the
cabinet, and beyond to
the next stud.
Insert a 2" X 6" wood
block, #2 grade or better,
[or a Danback™ flexible
wood backing system]
horizontally between each
of the exposed studs.
Fasten the wood block
to each stud using three
screws at the ends of
each block.
Replace the drywall and
repair as desired.
Fasten the Knoll supplied
wall mounting cleat, rail,
frame, etc directly to the
wood block every 6"
For wall mounting
structures that have a
rectangular frame-like
configuration: fasten the
top horizontal element of
the frame to the wood
blocking every 6", and
fasten the lower horizontal
element to each wall
stud, using one fastener
per stud.
#10 x 2 1/2" Grabber
Woodys Screws or equiv.
@ 6" c/c, screwed directly
into the wood blocking
Track across the top of
the studs with diagonal
studs attached to
underside of roof /
floor structure above
Toggler Snapskru
drywall anchors
with #8 x 2" screw
@ 4-1/2" c/c with
2-1/2" end distance
No