A.3.5

Block-specific error messages

Table A- 5
Block
FB 45
Ident profile
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
A.3 Operation of optical handheld readers, access control readers or serial devices
Block-specific error messages
Error ID
Meaning
0x06
Negative acknowledgment or bad frame from the reader
0x05
Unknown command, incorrect command parameters or forbidden
command chaining (wrong length information)
0x0D
Address error in the command (≠ "0x0000", "0x0002", "0xFFFF)
0x12
Internal communication error
0x13
New data was received before existing data was fetched.
With the "Write" command the oldest acknowledgments are lost
without an error message being generated.
0x18
"Init_Run" necessary
0x1F
Active command was canceled by "Reset" (init_run) or bus con-
nector was unplugged
0xE2FE01
Negative acknowledgment or bad frame from the reader
0xE6FE01
Unknown command, incorrect command parameters or forbidden
command chaining (wrong length information)
0xE1FE03
Address error in the command (≠ "0x0000", "0x0002", "0xFFFF)
0xE4FE8D
Internal communication error
0xE4FE04
New data was received before existing data was fetched.
With the "Write" command the oldest acknowledgements are lost
without an error message being generated.
0xE6FE05
"Reset_Reader" necessary
0xE5FE04
Invalid data block number (DBN) on the reader/communication
module
Scan operation: The newest data is lost.
Scan operation: The newest data is lost.
Appendix