Programming via OPC UA
10.3 OPC UA events
Table 10- 30 Command
Data type
Description
Possible values
The property "LastAccessResult" is a field of "RfidLastAccessResult" structures. A field entry
or a structure carries the information for a transponder that was accessed by the
"Command". If multiple transponders were accessed by the command, the field has multiple
entries.
138
String
Command that was executed during the last transponder access
operation.
Depending on the client interface used:
PNIO, PB, EIB
(Ident profile):
INVENTORY
WRITE-ID
KILL-TAG
LOCK-TAG-BANK
PHYSICAL-READ
PHYSICAL-WRITE
FORMAT
TAG-STATUS
GET
PUT
NEXT
OPC UA:
Scan
ReadTag
WriteTag
KillTag
LockTag
SetTagPassword
Read
Write
READPOINT:
Observed
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
PNIO, PB (FB 45):
WRITE
READ
INIT
MDS-STATUS
WBM, XML:
readTagIDs
writeTagID
readTagMemory
writeTagMemory
killTag
lockTagBank
getTagStatus
--